Resumo: | Purpose: Titanium alloys are commonly used for prosthetic abutments fabrication, but these alloys present high cost and difficult handling. Alternative Ni-Cr alloys with Mo and Ti combination have been proposed. This study compared the alloys Ti-6Al-4V and Ni-Cr-Ti-Mo by analyzing their surface properties such as hardness, morphology and microstructural characterization. Methods: Five discs (5 x 2 mm) of commercially Ti-6Al-4V and Ni-Cr-Ti-Mo alloys were used to evaluate Vickers hardness by hardness micro indentation test. The same specimens were analyzed by scanning electron microscopy (SEM) regarding surface morphology and subjected to a metallographic analysis of the microstructure by optical microscopy. Data on surface hardness were analyzed using one-way ANOVA followed by Tukey test (α = 0.05). Results: The Ni-Cr-Mo-Ti alloy showed significantly higher Vickers hardness (kg/mm2) values (452.2 ± 3.9) than the Ti-6Al-4V alloy (375.7 ± 15.2). The surface morphology evaluated by SEM revealed differences between the alloys. Metallographic analyses, for both alloys, showed a two-phase equilibrium microstructure, with the presence of e α + β phase for Ti-6Al-4V; and gamma (γ) primary phase and gamma-prime (γ’) as a second phase for Ni-Cr-Mo-Ti. Conclusion: It can be concluded that both alloys present the requirements to be used in prosthetic abutments. |
id |
PUC_RS-22_b867e30d8a7eba469d02f33a2b14e3c6 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/5408 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutmentsCaracterização microestrutural das ligas Ni-Cr-Mo-Ti e Ti-6Al-4V utilizadas para pilares de prótesesTi-6Al-4VNi-Cr-Mo-Tidental alloymicrostructurehardnessabutmentmetal alloysPurpose: Titanium alloys are commonly used for prosthetic abutments fabrication, but these alloys present high cost and difficult handling. Alternative Ni-Cr alloys with Mo and Ti combination have been proposed. This study compared the alloys Ti-6Al-4V and Ni-Cr-Ti-Mo by analyzing their surface properties such as hardness, morphology and microstructural characterization. Methods: Five discs (5 x 2 mm) of commercially Ti-6Al-4V and Ni-Cr-Ti-Mo alloys were used to evaluate Vickers hardness by hardness micro indentation test. The same specimens were analyzed by scanning electron microscopy (SEM) regarding surface morphology and subjected to a metallographic analysis of the microstructure by optical microscopy. Data on surface hardness were analyzed using one-way ANOVA followed by Tukey test (α = 0.05). Results: The Ni-Cr-Mo-Ti alloy showed significantly higher Vickers hardness (kg/mm2) values (452.2 ± 3.9) than the Ti-6Al-4V alloy (375.7 ± 15.2). The surface morphology evaluated by SEM revealed differences between the alloys. Metallographic analyses, for both alloys, showed a two-phase equilibrium microstructure, with the presence of e α + β phase for Ti-6Al-4V; and gamma (γ) primary phase and gamma-prime (γ’) as a second phase for Ni-Cr-Mo-Ti. Conclusion: It can be concluded that both alloys present the requirements to be used in prosthetic abutments.Objetivo: As ligas de titânio são comumente usadas para a fabricação de componentes protéticos, entretanto apresentam alto custo e dificuldade de manuseio laboratorial. Ligas alternativas a base de Ni-Cr combinadas com Mo e Ti também tem sido propostas com o mesmo objeto. Este estudo comparou as ligas Ti-6Al-4V e Ni-Cr-Ti-Mo pela análise de suas propriedades de superfície como dureza, morfologia e caracterização da microestrutura. Metodologia: Cinco discos (5 × 2 mm) das ligas Ti-6Al-4V e Ni-Cr-Ti-Mo foram utilizados para a avaliação da dureza Vickers, análise de morfologia de superfície por meio da microscopia eletrônica de varredura (MEV) e análise da microestrutura pela análise metalográfica. Os dados da dureza de superfície foram analisados pela Análise de Variância a um nível seguida do teste de Tukey (α = 0,05). Resultados: A liga Ni-Cr-Mo-Ti apresentou os maiores valores de dureza Vickers (kg/mm2) (452,2 ± 3,9) comparada a liga Ti-6Al-4V (375,7 ± 15,2) A morfologia de superfície avaliada por MEV revelou características distintas entre as ligas. A análise metalográfica para ambas as ligas mostrou uma microestrutura com equilíbrio de duas fases, com a presença de fase α + β para Ti-6Al-4V; e fase gamma primária (γ) e fase gamma-prime (γ') como secundária para Ni-Cr-Mo-Ti. Conclusão: Ambas as ligas podem ser utilizadas para fabricação de pilares protéticos.EDIPUCRS - Editora Universitária da PUCRS2009-08-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articledescriptive; laboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408Revista Odonto Ciência; Vol. 24 No. 4 (2009); 401 - 405Revista Odonto Ciência; v. 24 n. 4 (2009); 401 - 4051980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408/4782Faot, FernandaSilva, Wander José daR. Garcia, Renata Cunha MatheusDel Bel Cury, Altair Antoninhainfo:eu-repo/semantics/openAccess2013-11-11T12:57:32Zoai:ojs.revistaseletronicas.pucrs.br:article/5408Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T12:57:32Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments Caracterização microestrutural das ligas Ni-Cr-Mo-Ti e Ti-6Al-4V utilizadas para pilares de próteses |
title |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments |
spellingShingle |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments Faot, Fernanda Ti-6Al-4V Ni-Cr-Mo-Ti dental alloy microstructure hardness abutment metal alloys |
title_short |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments |
title_full |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments |
title_fullStr |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments |
title_full_unstemmed |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments |
title_sort |
Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments |
author |
Faot, Fernanda |
author_facet |
Faot, Fernanda Silva, Wander José da R. Garcia, Renata Cunha Matheus Del Bel Cury, Altair Antoninha |
author_role |
author |
author2 |
Silva, Wander José da R. Garcia, Renata Cunha Matheus Del Bel Cury, Altair Antoninha |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Faot, Fernanda Silva, Wander José da R. Garcia, Renata Cunha Matheus Del Bel Cury, Altair Antoninha |
dc.subject.por.fl_str_mv |
Ti-6Al-4V Ni-Cr-Mo-Ti dental alloy microstructure hardness abutment metal alloys |
topic |
Ti-6Al-4V Ni-Cr-Mo-Ti dental alloy microstructure hardness abutment metal alloys |
description |
Purpose: Titanium alloys are commonly used for prosthetic abutments fabrication, but these alloys present high cost and difficult handling. Alternative Ni-Cr alloys with Mo and Ti combination have been proposed. This study compared the alloys Ti-6Al-4V and Ni-Cr-Ti-Mo by analyzing their surface properties such as hardness, morphology and microstructural characterization. Methods: Five discs (5 x 2 mm) of commercially Ti-6Al-4V and Ni-Cr-Ti-Mo alloys were used to evaluate Vickers hardness by hardness micro indentation test. The same specimens were analyzed by scanning electron microscopy (SEM) regarding surface morphology and subjected to a metallographic analysis of the microstructure by optical microscopy. Data on surface hardness were analyzed using one-way ANOVA followed by Tukey test (α = 0.05). Results: The Ni-Cr-Mo-Ti alloy showed significantly higher Vickers hardness (kg/mm2) values (452.2 ± 3.9) than the Ti-6Al-4V alloy (375.7 ± 15.2). The surface morphology evaluated by SEM revealed differences between the alloys. Metallographic analyses, for both alloys, showed a two-phase equilibrium microstructure, with the presence of e α + β phase for Ti-6Al-4V; and gamma (γ) primary phase and gamma-prime (γ’) as a second phase for Ni-Cr-Mo-Ti. Conclusion: It can be concluded that both alloys present the requirements to be used in prosthetic abutments. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-08-10 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article descriptive; laboratory |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408/4782 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 24 No. 4 (2009); 401 - 405 Revista Odonto Ciência; v. 24 n. 4 (2009); 401 - 405 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820874921312256 |