Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study

Detalhes bibliográficos
Autor(a) principal: Brito Júnior, Manoel
Data de Publicação: 2007
Outros Autores: Soares, Janir Alves, Camilo, Carla Cristina, Oliveira, Alba Moura
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1275
Resumo: The aim of this in vitro study was to evaluate the accuracy and reliability of an electronic apex locator (EAL) in the determination of the working length (WL) of lower molars. After appropriate endodontic access and exploration in 20 teeth, it was measured with a size 10 K-file the actual canal length (AL) of the mesio-buccal (MB) and distal (D) root canals until the apical foramen. Next, it was subtracted 1mm of the AL (WL1), taking as coronal references the vertex of the mesio-buccal and disto-buccal cusps. The teeth were embedded in an alginate model and electronic tooth length measurements were carried out using the EAL Novapex (Fórum, Israel). A 10 K-type file was inserted down the MB and D canals until EAL indicated that the file had reached the apex retreating until the mark 1. The cursors were adjusted in the same external references of WL1. The eletronic measurements were obtained by two operators, a graduate student (WL2) and a specialist (WL3). Three measurements were taken and an average recorded. The coefficient of Pearson revealed high concordance level inter-operators and intra-operators. For comparison of WL1, WL2 and WL3 the test t of Student was applied (p < 0,05). There was no statistically significant difference between all the measures for MB (p = 0,22) and D (p = 0,94) root canals. Therefore, the tested EAL was accurate and reliable in the determination of the WL of lower molars. UNITERMS: apex locator; working length; lower molars.
id PUC_RS-22_bf00e6828e7d66b5a07e1d8441cc336e
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/1275
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro studyPrecisão e confiabilidade de um localizador apical na odontometria de molares inferiores. estudo in vitroapex locatorworking lengthlower molars.Root canal preparationThe aim of this in vitro study was to evaluate the accuracy and reliability of an electronic apex locator (EAL) in the determination of the working length (WL) of lower molars. After appropriate endodontic access and exploration in 20 teeth, it was measured with a size 10 K-file the actual canal length (AL) of the mesio-buccal (MB) and distal (D) root canals until the apical foramen. Next, it was subtracted 1mm of the AL (WL1), taking as coronal references the vertex of the mesio-buccal and disto-buccal cusps. The teeth were embedded in an alginate model and electronic tooth length measurements were carried out using the EAL Novapex (Fórum, Israel). A 10 K-type file was inserted down the MB and D canals until EAL indicated that the file had reached the apex retreating until the mark 1. The cursors were adjusted in the same external references of WL1. The eletronic measurements were obtained by two operators, a graduate student (WL2) and a specialist (WL3). Three measurements were taken and an average recorded. The coefficient of Pearson revealed high concordance level inter-operators and intra-operators. For comparison of WL1, WL2 and WL3 the test t of Student was applied (p < 0,05). There was no statistically significant difference between all the measures for MB (p = 0,22) and D (p = 0,94) root canals. Therefore, the tested EAL was accurate and reliable in the determination of the WL of lower molars. UNITERMS: apex locator; working length; lower molars.O presente estudo in vitro teve por objetivo avaliar a precisão e a confibialidade de um modelo de localizador apical eletrônico (LAE) na obtenção do comprimento de trabalho (CT) em molares inferiores. Após adequado acesso endodôntico e manobras iniciais de exploração em 20 dentes, mediu-se com uma lima K # 10 o comprimento dos condutos mésio-vestibular (MV) e distal (D) até o forame apical, subtraindo-se 1 mm (CT1), tendo como referências externas as cúspides mésio-vestibular e disto-vestibular, respectivamente. Os dentes foram fixados em recipientes plásticos contendo alginato procedendo-se as medidas eletrônicas com o LAE Novapex (Fórum,Israel). Limas K # 10 foram inseridas nos canais MV e D até que os instrumentos atingissem a marca 0 no visor do aparelho e posteriormente realizava-se o recuo até a marca 1, ajustando-se os cursores nas mesmas referências externas do CT1. As mensurações com o LAE foram realizadas em triplicata, adotando-se a média das medidas, por dois operadores calibrados, um estudante de gradução (CT2) e um especialista em endodontia (CT3). O coeficiente de correlação linear de Pearson revelou alta concorcândia inter–operadores e intraoperadores. Para comparação do CT1, CT2 e CT3 foi aplicado o Teste t de Student para amostras pareadas (p < 0,05), que não mostrou diferenças significativas entre todas as medidas odontométricas para os canais radiculares MV (p = 0,22 ) e D (p = 0,94). Portanto, o LAE testado mostrou-se preciso e confiável na determinação da odontometria de molares inferiores. UNITERMOS: localizador apical eletrônico; odontometria; molares inferiores.EDIPUCRS - Editora Universitária da PUCRS2007-12-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratory; correlationalapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1275Revista Odonto Ciência; Vol. 22 No. 58 (2007); 293 - 298Revista Odonto Ciência; v. 22 n. 58 (2007); 293 - 2981980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1275/1914Brito Júnior, ManoelSoares, Janir AlvesCamilo, Carla CristinaOliveira, Alba Mourainfo:eu-repo/semantics/openAccess2013-11-18T11:02:30Zoai:ojs.revistaseletronicas.pucrs.br:article/1275Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T11:02:30Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
Precisão e confiabilidade de um localizador apical na odontometria de molares inferiores. estudo in vitro
title Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
spellingShingle Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
Brito Júnior, Manoel
apex locator
working length
lower molars.
Root canal preparation
title_short Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
title_full Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
title_fullStr Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
title_full_unstemmed Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
title_sort Accuracy and reliability of an apex locator for working length determination of lower molars. an in vitro study
author Brito Júnior, Manoel
author_facet Brito Júnior, Manoel
Soares, Janir Alves
Camilo, Carla Cristina
Oliveira, Alba Moura
author_role author
author2 Soares, Janir Alves
Camilo, Carla Cristina
Oliveira, Alba Moura
author2_role author
author
author
dc.contributor.author.fl_str_mv Brito Júnior, Manoel
Soares, Janir Alves
Camilo, Carla Cristina
Oliveira, Alba Moura
dc.subject.por.fl_str_mv apex locator
working length
lower molars.
Root canal preparation
topic apex locator
working length
lower molars.
Root canal preparation
description The aim of this in vitro study was to evaluate the accuracy and reliability of an electronic apex locator (EAL) in the determination of the working length (WL) of lower molars. After appropriate endodontic access and exploration in 20 teeth, it was measured with a size 10 K-file the actual canal length (AL) of the mesio-buccal (MB) and distal (D) root canals until the apical foramen. Next, it was subtracted 1mm of the AL (WL1), taking as coronal references the vertex of the mesio-buccal and disto-buccal cusps. The teeth were embedded in an alginate model and electronic tooth length measurements were carried out using the EAL Novapex (Fórum, Israel). A 10 K-type file was inserted down the MB and D canals until EAL indicated that the file had reached the apex retreating until the mark 1. The cursors were adjusted in the same external references of WL1. The eletronic measurements were obtained by two operators, a graduate student (WL2) and a specialist (WL3). Three measurements were taken and an average recorded. The coefficient of Pearson revealed high concordance level inter-operators and intra-operators. For comparison of WL1, WL2 and WL3 the test t of Student was applied (p < 0,05). There was no statistically significant difference between all the measures for MB (p = 0,22) and D (p = 0,94) root canals. Therefore, the tested EAL was accurate and reliable in the determination of the WL of lower molars. UNITERMS: apex locator; working length; lower molars.
publishDate 2007
dc.date.none.fl_str_mv 2007-12-27
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
laboratory; correlational
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1275
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1275
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1275/1914
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 22 No. 58 (2007); 293 - 298
Revista Odonto Ciência; v. 22 n. 58 (2007); 293 - 298
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820873752150016