Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error

Detalhes bibliográficos
Autor(a) principal: Machado, Letícia Alves
Data de Publicação: 2012
Outros Autores: Vilella, Oswaldo de Vasconcellos, Machado, Leticia
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9729
Resumo: Purpose: To evaluate the influence of errors when two methods for assessing the available space in the dental arch are used. Methods: A single investigator measured the available space in 30 plaster models by using two techniques: 1) with a digital caliper; and 2) by contouring the arch with a brass wire and subsequently straightening and measuring this wire with a millimeter ruler. Fifteen days later, data were collected using both methods with duplicate measurements, so that each method was used twice for each model. The random and systematic errors of each method under the conditions of repeatability and reproducibility were calculated. Results: For method reproducibility, systematic errors were statistically significant (P
id PUC_RS-22_cb47cfff12d0a8533584247593a36f41
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/9729
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Evaluation of two techniques to measure the available space in the mandibular dental arch using the method errorAvaliação de duas técnicas de aferição do espaço presente no arco dentário inferior quanto ao erro do métodoDental archspace measurementreproducibilityArco dentalmedição de espaçoreprodutibilidadePurpose: To evaluate the influence of errors when two methods for assessing the available space in the dental arch are used. Methods: A single investigator measured the available space in 30 plaster models by using two techniques: 1) with a digital caliper; and 2) by contouring the arch with a brass wire and subsequently straightening and measuring this wire with a millimeter ruler. Fifteen days later, data were collected using both methods with duplicate measurements, so that each method was used twice for each model. The random and systematic errors of each method under the conditions of repeatability and reproducibility were calculated. Results: For method reproducibility, systematic errors were statistically significant (P Objetivo: Avaliar a influência dos erros quando dois métodos para avaliação do espaço presente no arco dentário são utilizados. Métodos: Um examinador único realizou a aferição do espaço presente em 30 modelos de gesso através de duas técnicas: 1) mensuração realizada com paquímetro digital; e 2) mensuração feita através do contorno do arco com fio de latão e medição deste com régua milimetrada. Após 15 dias, esta análise foi novamente realizada, utilizando os dois métodos, sendo que cada um deles foi empregado duas vezes consecutivas em cada modelo. Assim, foram obtidos dados em condição de repetibilidade e de reprodutibilidade e os erros sistemáticos e aleatórios de cada método nestas condições foram calculados. Resultados: Os erros sistemáticos foram significativos (P < 0,05) apenas na condição de reprodutibilidade para o método com fio de latão. Com paquímetro, a análise dos erros aleatórios mostrou que os erros presentes foram inferiores a 1 mm nas duas condições. Com fio de latão estes erros não existiram em condição de repetibilidade, porém foram de 1,69 mm em condição de reprodutibilidade. Conclusões: No método com paquímetro digital os erros sistemático e aleatório foram considerados aceitáveis. O método de medição com fio de latão não apresentou erro para repetibilidade. Para reprodutibilidade, no entanto, o erro sistemático foi significante e o erro aleatório encontrado fez com que este método fosse considerado no presente estudo como inapropriado.EDIPUCRS - Editora Universitária da PUCRS2012-09-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9729Revista Odonto Ciência; Vol. 27 No. 3 (2012); 228 - 232Revista Odonto Ciência; v. 27 n. 3 (2012); 228 - 2321980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9729/8454Machado, Letícia AlvesVilella, Oswaldo de VasconcellosMachado, Leticiainfo:eu-repo/semantics/openAccess2013-11-11T15:47:01Zoai:ojs.revistaseletronicas.pucrs.br:article/9729Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T15:47:01Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
Avaliação de duas técnicas de aferição do espaço presente no arco dentário inferior quanto ao erro do método
title Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
spellingShingle Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
Machado, Letícia Alves
Dental arch
space measurement
reproducibility
Arco dental
medição de espaço
reprodutibilidade
title_short Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
title_full Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
title_fullStr Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
title_full_unstemmed Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
title_sort Evaluation of two techniques to measure the available space in the mandibular dental arch using the method error
author Machado, Letícia Alves
author_facet Machado, Letícia Alves
Vilella, Oswaldo de Vasconcellos
Machado, Leticia
author_role author
author2 Vilella, Oswaldo de Vasconcellos
Machado, Leticia
author2_role author
author
dc.contributor.author.fl_str_mv Machado, Letícia Alves
Vilella, Oswaldo de Vasconcellos
Machado, Leticia
dc.subject.por.fl_str_mv Dental arch
space measurement
reproducibility
Arco dental
medição de espaço
reprodutibilidade
topic Dental arch
space measurement
reproducibility
Arco dental
medição de espaço
reprodutibilidade
description Purpose: To evaluate the influence of errors when two methods for assessing the available space in the dental arch are used. Methods: A single investigator measured the available space in 30 plaster models by using two techniques: 1) with a digital caliper; and 2) by contouring the arch with a brass wire and subsequently straightening and measuring this wire with a millimeter ruler. Fifteen days later, data were collected using both methods with duplicate measurements, so that each method was used twice for each model. The random and systematic errors of each method under the conditions of repeatability and reproducibility were calculated. Results: For method reproducibility, systematic errors were statistically significant (P
publishDate 2012
dc.date.none.fl_str_mv 2012-09-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9729
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9729
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9729/8454
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 27 No. 3 (2012); 228 - 232
Revista Odonto Ciência; v. 27 n. 3 (2012); 228 - 232
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820875896487936