Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6764 |
Resumo: | Purpose: This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal hexagon implant with straight and angled abutments. Methods: Four groups of implants and abutments were assessed combining internal and external hexagon and straight and angled abutments, which were retained by titanium screws tightened to 20 Ncm. Crowns were retained with gold screws tightened at 10 N.cm. A vertical line was ascribed across the implant-abutment-crown interface to verify horizontal displacement by a light microscope. The fatigue tests were performed in a servo-hydraulic machine, which delivered forces between 100 and 120 N for 250,000 cycles. The screw was removed, and the detorque value was recorded. Data were analyzed with 2-way ANOVA and Tukey’s test. Results: No horizontal displacement was observed on the interface of implant-abutment or abutment and crown. It was found significant difference for prosthetic screw between implant connection types, but without interaction with abutment. However, for abutment screw, there was a difference between implant connection types and abutment with interaction between implant and abutments. The straight abutment showed significant better performance than the 17° angled abutment. Conclusion: The connection implant types or abutment affected pre-tightening maintenance. Internal and external hexed connections were effective to avoid horizontal displacement of crowns. |
id |
PUC_RS-22_ebaad7c54fb8fe6c3202a7b48336d4e0 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/6764 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connectionsAvaliação do pré-aparafusamento em pilares e parafusos protéticos em diferentes conexões de implanteAngled abutmentsfatigue testingimplant dentistryimplant connectionImplantsPilar anguladoteste de fadigaimplantodontiaconexão do implanteImplantes dentáriosPurpose: This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal hexagon implant with straight and angled abutments. Methods: Four groups of implants and abutments were assessed combining internal and external hexagon and straight and angled abutments, which were retained by titanium screws tightened to 20 Ncm. Crowns were retained with gold screws tightened at 10 N.cm. A vertical line was ascribed across the implant-abutment-crown interface to verify horizontal displacement by a light microscope. The fatigue tests were performed in a servo-hydraulic machine, which delivered forces between 100 and 120 N for 250,000 cycles. The screw was removed, and the detorque value was recorded. Data were analyzed with 2-way ANOVA and Tukey’s test. Results: No horizontal displacement was observed on the interface of implant-abutment or abutment and crown. It was found significant difference for prosthetic screw between implant connection types, but without interaction with abutment. However, for abutment screw, there was a difference between implant connection types and abutment with interaction between implant and abutments. The straight abutment showed significant better performance than the 17° angled abutment. Conclusion: The connection implant types or abutment affected pre-tightening maintenance. Internal and external hexed connections were effective to avoid horizontal displacement of crowns.Objetivo: Este estudo avaliou a manutenção do pré-aparafusamento em pilar e parafuso protético de implantes com hexágono interno e externo, com pilares retos e angulados. Metodologia: Quatro grupos de implantes e pilares foram avaliados, combinando-se o hexágono interno ou externo e o pilar reto ou angulado, os quais foram retidos por parafusos de titânio aparafusados 20 Ncm. As coroas fora retidas com parafusos de ouro aparafusados a 10 Ncm. Uma linha vertical foi delineada sobre a interface implante-pilar-coroa para verificar o deslocamento vertical com uso de microscópio ótico. Os testes de fadiga foram realizados em uma máquina servo-hidráulica, que promoveu forças entre 100 e 120 N por 250.000 ciclos. O parafuso foi removido e o valor de detorque for registrado. Os dados foram analisados por ANOVA de dois fatores e teste de Tukey. Resultados: Nenhum deslocamento horizontal foi observado na interface implante-pilar ou pilar-coroa. Observou-se uma diferença significativa para o parafuso protético entre os tipos de conexão do implante, mas sem interação com o pilar. Porém, para o parafuso do pilar houve diferença entre tipos de conexão e pilar, com interação entre pilar e implante. O pilar reto mostrou melhor performance que o pilar angulado a 17°. Conclusão: Os tipos de conexão do implante ou pilar afetaram a manutenção do pré-aparafusamento. As conexões de hexágono interno e externo foram efetivas para evitar o deslocamento horizontal das coroas.EDIPUCRS - Editora Universitária da PUCRS2010-09-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlein vitro; laboratorial; experimentalin vitro; laboratorial; experimentalapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6764Revista Odonto Ciência; Vol. 25 No. 3 (2010); 292 - 295Revista Odonto Ciência; v. 25 n. 3 (2010); 292 - 2951980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6764/5551Panza, LeonardoBoscatto, NoeliDel Bel Cury, Altair Antoninhainfo:eu-repo/semantics/openAccess2013-11-11T12:30:19Zoai:ojs.revistaseletronicas.pucrs.br:article/6764Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T12:30:19Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections Avaliação do pré-aparafusamento em pilares e parafusos protéticos em diferentes conexões de implante |
title |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections |
spellingShingle |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections Panza, Leonardo Angled abutments fatigue testing implant dentistry implant connection Implants Pilar angulado teste de fadiga implantodontia conexão do implante Implantes dentários |
title_short |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections |
title_full |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections |
title_fullStr |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections |
title_full_unstemmed |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections |
title_sort |
Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections |
author |
Panza, Leonardo |
author_facet |
Panza, Leonardo Boscatto, Noeli Del Bel Cury, Altair Antoninha |
author_role |
author |
author2 |
Boscatto, Noeli Del Bel Cury, Altair Antoninha |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Panza, Leonardo Boscatto, Noeli Del Bel Cury, Altair Antoninha |
dc.subject.por.fl_str_mv |
Angled abutments fatigue testing implant dentistry implant connection Implants Pilar angulado teste de fadiga implantodontia conexão do implante Implantes dentários |
topic |
Angled abutments fatigue testing implant dentistry implant connection Implants Pilar angulado teste de fadiga implantodontia conexão do implante Implantes dentários |
description |
Purpose: This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal hexagon implant with straight and angled abutments. Methods: Four groups of implants and abutments were assessed combining internal and external hexagon and straight and angled abutments, which were retained by titanium screws tightened to 20 Ncm. Crowns were retained with gold screws tightened at 10 N.cm. A vertical line was ascribed across the implant-abutment-crown interface to verify horizontal displacement by a light microscope. The fatigue tests were performed in a servo-hydraulic machine, which delivered forces between 100 and 120 N for 250,000 cycles. The screw was removed, and the detorque value was recorded. Data were analyzed with 2-way ANOVA and Tukey’s test. Results: No horizontal displacement was observed on the interface of implant-abutment or abutment and crown. It was found significant difference for prosthetic screw between implant connection types, but without interaction with abutment. However, for abutment screw, there was a difference between implant connection types and abutment with interaction between implant and abutments. The straight abutment showed significant better performance than the 17° angled abutment. Conclusion: The connection implant types or abutment affected pre-tightening maintenance. Internal and external hexed connections were effective to avoid horizontal displacement of crowns. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-09-29 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article in vitro; laboratorial; experimental in vitro; laboratorial; experimental |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6764 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6764 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6764/5551 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 25 No. 3 (2010); 292 - 295 Revista Odonto Ciência; v. 25 n. 3 (2010); 292 - 295 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820875381637120 |