A utilização do estímulo ce-chirp® na triagem auditiva neonatal
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da PUC_SP |
Texto Completo: | https://tede2.pucsp.br/handle/handle/11973 |
Resumo: | The Automated Auditory Brainstem Response (AABR) test with click stimulus is a traditionally used procedure for the identification of hearing loss at birth. New stimuli have been developed and optimized to improve the efficiency of identification of different types and degrees of hearing loss. The aim of this thesis was to study the use of CE-chirp® stimulus in Newborn Hearing Screening (NHS) through AABR test. Participants were newborns both with and without Risk Indicators for Hearing Loss. AABR tests with click stimulus, CE-chirp® and Hi-Lo CE-chirp® were performed at intensities between 30 and 35 dBHL in both ears. Diagnostic ABR tests with click stimulus were performed on all newborns as the gold-standard procedure. The AABR test results for each stimulus and intensity were presented and compared to the diagnostic ABR tests with click stimulus. "Pass / refer" results were analyzed and validation values and response detection time were determined. The results showed that for sensorineural alterations, sensitivity measures were similar for the two stimuli types. However, the specificity was higher for the CE-chirp® in the two intensities. The average response detection time was lower for the CE-chirp® stimulus when compared to the click stimulus, being more statistically significant in the intensity of 35 dBHL for both ears and in the intensity of 30dBHL for the right ear (p<0,001). The Hi-Lo CE-chirp® stimulus presented high sensitivity and low specificity and considerably short average detection time. AABR tests with CE-chirp® stimulus showed to be effective in the identification of permanent and disabling hearing loss, however, new studies need to be performed with conductive and sensorineural mild hearing loss. The results showed that the band limited CE-chirp® still needs to be improved for future clinical application in automatic procedures for the purpose of hearing screening |
id |
PUC_SP-1_c43bd94a824bf69c0e66c7fc30402c24 |
---|---|
oai_identifier_str |
oai:repositorio.pucsp.br:handle/11973 |
network_acronym_str |
PUC_SP-1 |
network_name_str |
Biblioteca Digital de Teses e Dissertações da PUC_SP |
repository_id_str |
|
spelling |
Lewis, Doris Ruthyhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4255170D2Almeida, Mabel Gonçalves2016-04-27T18:12:02Z2013-10-312013-08-13Almeida, Mabel Gonçalves. A utilização do estímulo ce-chirp® na triagem auditiva neonatal. 2013. 193 f. Tese (Doutorado em Fonoaudiologia) - Pontifícia Universidade Católica de São Paulo, São Paulo, 2013.https://tede2.pucsp.br/handle/handle/11973The Automated Auditory Brainstem Response (AABR) test with click stimulus is a traditionally used procedure for the identification of hearing loss at birth. New stimuli have been developed and optimized to improve the efficiency of identification of different types and degrees of hearing loss. The aim of this thesis was to study the use of CE-chirp® stimulus in Newborn Hearing Screening (NHS) through AABR test. Participants were newborns both with and without Risk Indicators for Hearing Loss. AABR tests with click stimulus, CE-chirp® and Hi-Lo CE-chirp® were performed at intensities between 30 and 35 dBHL in both ears. Diagnostic ABR tests with click stimulus were performed on all newborns as the gold-standard procedure. The AABR test results for each stimulus and intensity were presented and compared to the diagnostic ABR tests with click stimulus. "Pass / refer" results were analyzed and validation values and response detection time were determined. The results showed that for sensorineural alterations, sensitivity measures were similar for the two stimuli types. However, the specificity was higher for the CE-chirp® in the two intensities. The average response detection time was lower for the CE-chirp® stimulus when compared to the click stimulus, being more statistically significant in the intensity of 35 dBHL for both ears and in the intensity of 30dBHL for the right ear (p<0,001). The Hi-Lo CE-chirp® stimulus presented high sensitivity and low specificity and considerably short average detection time. AABR tests with CE-chirp® stimulus showed to be effective in the identification of permanent and disabling hearing loss, however, new studies need to be performed with conductive and sensorineural mild hearing loss. The results showed that the band limited CE-chirp® still needs to be improved for future clinical application in automatic procedures for the purpose of hearing screeningO Potencial Evocado Auditivo de Tronco Encefálico Automático (PEATE-A) com o estímulo clique é um procedimento tradicionalmente utilizado para identificação de perda auditiva ao nascimento. Novos estímulos têm sido desenvolvidos e otimizados em busca de melhorar a eficiência na identificação de diferentes tipos e graus de perdas auditivas. O objetivo dessa tese foi estudar a utilização do estímulo CE-chirp® na Triagem Auditiva Neonatal (TAN) por meio do PEATE-A. Participaram desse estudo Recém-Nascidos (RN) com e sem Indicadores de Risco para Deficiência Auditiva (IRDA). O PEATE- A com estímulo clique, CE-chirp® e o Hi-Lo CEchirp ® foi realizado nas intensidades de 30 e 35 dBnNA nas duas orelhas. O PEATE diagnóstico com estímulo clique foi realizado em todos os RN como procedimento padrão-ouro. Os resultados do PEATE-A para cada estímulo e intensidade foram comparados entre si e ao PEATE diagnóstico com estímulo clique. Foram analisados os resultados passa/falha e determinados valores de medidas de habilidade diagnóstica e o tempo de detecção de resposta. Os resultados encontrados mostraram que para alterações sensorioneurais, as medidas de sensibilidade foram semelhantes para os dois estímulos, no entanto, a especificidade foi maior para o CEchirp ® nas duas intensidades. O tempo médio de detecção de resposta foi menor para o estímulo CE-chirp® quando comparado ao clique, sendo estatisticamente significante na intensidade de 35 dBnNA para ambas as orelhas e na orelha direita para 30 dB nNA (P<0,001). O estímulo Hi-lo CEchirp ® apresentou alta sensibilidade e baixa especificidade e tempo médio de detecção consideravelmente pequeno. O PEATE-A com estímulo CEchirp ® mostrou ser eficiente na identificação de perdas auditivas permanentes e incapacitantes, no entanto novos estudos necessitam ser realizados em predas auditivas leves condutivas e sensorioneurais. Os resultados mostraram que o CE-chirp® de banda limitada necessita ainda ser aprimorado para futura aplicação clínica em procedimentos automáticos com fins de triagem auditivaCoordenação de Aperfeiçoamento de Pessoal de Nível Superiorapplication/pdfhttp://tede2.pucsp.br/tede/retrieve/24862/Mabel%20Goncalves%20Almeida.pdf.jpgporPontifícia Universidade Católica de São PauloPrograma de Estudos Pós-Graduados em FonoaudiologiaPUC-SPBRFonoaudiologiaTestes auditivosAudiçãoRecém-nascidoPerda auditivaHearing testsHearingNewbornHearing lossCNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIAA utilização do estímulo ce-chirp® na triagem auditiva neonatalThe use of CE-chirp® stimulus in newborn hearing screeninginfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_SPinstname:Pontifícia Universidade Católica de São Paulo (PUC-SP)instacron:PUC_SPTEXTMabel Goncalves Almeida.pdf.txtMabel Goncalves Almeida.pdf.txtExtracted texttext/plain316990https://repositorio.pucsp.br/xmlui/bitstream/handle/11973/3/Mabel%20Goncalves%20Almeida.pdf.txtc6e6cc8a900856efb6f76b890dc9a92cMD53ORIGINALMabel Goncalves Almeida.pdfapplication/pdf8938851https://repositorio.pucsp.br/xmlui/bitstream/handle/11973/1/Mabel%20Goncalves%20Almeida.pdf302b76a48d9fed93b173e3498355c260MD51THUMBNAILMabel Goncalves Almeida.pdf.jpgMabel Goncalves Almeida.pdf.jpgGenerated Thumbnailimage/jpeg3180https://repositorio.pucsp.br/xmlui/bitstream/handle/11973/2/Mabel%20Goncalves%20Almeida.pdf.jpg65f685bda8694a943aad7cfc31808e55MD52handle/119732022-04-27 18:13:28.404oai:repositorio.pucsp.br:handle/11973Biblioteca Digital de Teses e Dissertaçõeshttps://sapientia.pucsp.br/https://sapientia.pucsp.br/oai/requestbngkatende@pucsp.br||rapassi@pucsp.bropendoar:2022-04-27T21:13:28Biblioteca Digital de Teses e Dissertações da PUC_SP - Pontifícia Universidade Católica de São Paulo (PUC-SP)false |
dc.title.por.fl_str_mv |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
dc.title.alternative.eng.fl_str_mv |
The use of CE-chirp® stimulus in newborn hearing screening |
title |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
spellingShingle |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal Almeida, Mabel Gonçalves Testes auditivos Audição Recém-nascido Perda auditiva Hearing tests Hearing Newborn Hearing loss CNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIA |
title_short |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
title_full |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
title_fullStr |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
title_full_unstemmed |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
title_sort |
A utilização do estímulo ce-chirp® na triagem auditiva neonatal |
author |
Almeida, Mabel Gonçalves |
author_facet |
Almeida, Mabel Gonçalves |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Lewis, Doris Ruthy |
dc.contributor.authorLattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4255170D2 |
dc.contributor.author.fl_str_mv |
Almeida, Mabel Gonçalves |
contributor_str_mv |
Lewis, Doris Ruthy |
dc.subject.por.fl_str_mv |
Testes auditivos Audição Recém-nascido Perda auditiva |
topic |
Testes auditivos Audição Recém-nascido Perda auditiva Hearing tests Hearing Newborn Hearing loss CNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIA |
dc.subject.eng.fl_str_mv |
Hearing tests Hearing Newborn Hearing loss |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIA |
description |
The Automated Auditory Brainstem Response (AABR) test with click stimulus is a traditionally used procedure for the identification of hearing loss at birth. New stimuli have been developed and optimized to improve the efficiency of identification of different types and degrees of hearing loss. The aim of this thesis was to study the use of CE-chirp® stimulus in Newborn Hearing Screening (NHS) through AABR test. Participants were newborns both with and without Risk Indicators for Hearing Loss. AABR tests with click stimulus, CE-chirp® and Hi-Lo CE-chirp® were performed at intensities between 30 and 35 dBHL in both ears. Diagnostic ABR tests with click stimulus were performed on all newborns as the gold-standard procedure. The AABR test results for each stimulus and intensity were presented and compared to the diagnostic ABR tests with click stimulus. "Pass / refer" results were analyzed and validation values and response detection time were determined. The results showed that for sensorineural alterations, sensitivity measures were similar for the two stimuli types. However, the specificity was higher for the CE-chirp® in the two intensities. The average response detection time was lower for the CE-chirp® stimulus when compared to the click stimulus, being more statistically significant in the intensity of 35 dBHL for both ears and in the intensity of 30dBHL for the right ear (p<0,001). The Hi-Lo CE-chirp® stimulus presented high sensitivity and low specificity and considerably short average detection time. AABR tests with CE-chirp® stimulus showed to be effective in the identification of permanent and disabling hearing loss, however, new studies need to be performed with conductive and sensorineural mild hearing loss. The results showed that the band limited CE-chirp® still needs to be improved for future clinical application in automatic procedures for the purpose of hearing screening |
publishDate |
2013 |
dc.date.available.fl_str_mv |
2013-10-31 |
dc.date.issued.fl_str_mv |
2013-08-13 |
dc.date.accessioned.fl_str_mv |
2016-04-27T18:12:02Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
Almeida, Mabel Gonçalves. A utilização do estímulo ce-chirp® na triagem auditiva neonatal. 2013. 193 f. Tese (Doutorado em Fonoaudiologia) - Pontifícia Universidade Católica de São Paulo, São Paulo, 2013. |
dc.identifier.uri.fl_str_mv |
https://tede2.pucsp.br/handle/handle/11973 |
identifier_str_mv |
Almeida, Mabel Gonçalves. A utilização do estímulo ce-chirp® na triagem auditiva neonatal. 2013. 193 f. Tese (Doutorado em Fonoaudiologia) - Pontifícia Universidade Católica de São Paulo, São Paulo, 2013. |
url |
https://tede2.pucsp.br/handle/handle/11973 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Pontifícia Universidade Católica de São Paulo |
dc.publisher.program.fl_str_mv |
Programa de Estudos Pós-Graduados em Fonoaudiologia |
dc.publisher.initials.fl_str_mv |
PUC-SP |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Fonoaudiologia |
publisher.none.fl_str_mv |
Pontifícia Universidade Católica de São Paulo |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da PUC_SP instname:Pontifícia Universidade Católica de São Paulo (PUC-SP) instacron:PUC_SP |
instname_str |
Pontifícia Universidade Católica de São Paulo (PUC-SP) |
instacron_str |
PUC_SP |
institution |
PUC_SP |
reponame_str |
Biblioteca Digital de Teses e Dissertações da PUC_SP |
collection |
Biblioteca Digital de Teses e Dissertações da PUC_SP |
bitstream.url.fl_str_mv |
https://repositorio.pucsp.br/xmlui/bitstream/handle/11973/3/Mabel%20Goncalves%20Almeida.pdf.txt https://repositorio.pucsp.br/xmlui/bitstream/handle/11973/1/Mabel%20Goncalves%20Almeida.pdf https://repositorio.pucsp.br/xmlui/bitstream/handle/11973/2/Mabel%20Goncalves%20Almeida.pdf.jpg |
bitstream.checksum.fl_str_mv |
c6e6cc8a900856efb6f76b890dc9a92c 302b76a48d9fed93b173e3498355c260 65f685bda8694a943aad7cfc31808e55 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da PUC_SP - Pontifícia Universidade Católica de São Paulo (PUC-SP) |
repository.mail.fl_str_mv |
bngkatende@pucsp.br||rapassi@pucsp.br |
_version_ |
1821691325178707968 |