Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas

Detalhes bibliográficos
Autor(a) principal: Cunha, Kael Seelig da
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_RS
Texto Completo: http://tede2.pucrs.br/tede2/handle/tede/9985
Resumo: Implant-supported fixed complete dentures (PTFI) present failures and complications over time. Thus, understanding the risk factors is necessary to develop strategies to reduce them. This prospective study aimed to evaluate the effect of PTFI geometric biomechanical parameters on perimplant bone remodeling up to one year of function. The sample consisted of images of computerized tomographic exams of 48 PTFI with metallic infrastructure and acrylic resin coat in edentulous maxilla and mandible (21 e 27 respectively), totaling 246 external hexagon implants. DICOM-format images were processed to measure: supporting polygon area, clinical crown/implant ratio (vertical lever), antero-posterior power and resistance arms, of anterior cantilever and posterior cantilever distances (horizontal levers) and perimplant bone remodeling (outcome measure). Data were analyzed by descriptive statistics and multilevel multivariable models. The results exhibited average bone loss, in one year of function, correspond to 0.88mm (0,82 ± 0,94). As for the arch, the results showed average bone loss of 0,62mm (0,57 ± 0,67) and 1,08mm (0,98 ± 1,18) in mandible and maxilla, respectively. The clinical crown/implant ratio (vertical lever) and anterior cantilever (power arm of the anterior horizontal lever) had a significant effect on perimplant bone loss, according to the implant position in the arch and measuring face. It can be concluded that perimplant bone loss increases with the vertical lever (crown / clinical implant ratio) and that the anterior cantilever has a protective effect at the lingual face in anterior implants. Under the biomechanical perspective, these variables should be considered when planning and executing PTFI.
id P_RS_ab975a740b328fbb4c22dc4eb0f43faf
oai_identifier_str oai:tede2.pucrs.br:tede/9985
network_acronym_str P_RS
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_RS
repository_id_str
spelling Shinkai, Rosemary Sadami Araihttp://lattes.cnpq.br/3590748675382890http://lattes.cnpq.br/6131608503910119Cunha, Kael Seelig da2021-11-30T19:57:08Z2020-02-28http://tede2.pucrs.br/tede2/handle/tede/9985Implant-supported fixed complete dentures (PTFI) present failures and complications over time. Thus, understanding the risk factors is necessary to develop strategies to reduce them. This prospective study aimed to evaluate the effect of PTFI geometric biomechanical parameters on perimplant bone remodeling up to one year of function. The sample consisted of images of computerized tomographic exams of 48 PTFI with metallic infrastructure and acrylic resin coat in edentulous maxilla and mandible (21 e 27 respectively), totaling 246 external hexagon implants. DICOM-format images were processed to measure: supporting polygon area, clinical crown/implant ratio (vertical lever), antero-posterior power and resistance arms, of anterior cantilever and posterior cantilever distances (horizontal levers) and perimplant bone remodeling (outcome measure). Data were analyzed by descriptive statistics and multilevel multivariable models. The results exhibited average bone loss, in one year of function, correspond to 0.88mm (0,82 ± 0,94). As for the arch, the results showed average bone loss of 0,62mm (0,57 ± 0,67) and 1,08mm (0,98 ± 1,18) in mandible and maxilla, respectively. The clinical crown/implant ratio (vertical lever) and anterior cantilever (power arm of the anterior horizontal lever) had a significant effect on perimplant bone loss, according to the implant position in the arch and measuring face. It can be concluded that perimplant bone loss increases with the vertical lever (crown / clinical implant ratio) and that the anterior cantilever has a protective effect at the lingual face in anterior implants. Under the biomechanical perspective, these variables should be considered when planning and executing PTFI.As próteses totais fixas implantossuportadas (PTFI) apresentam ocorrência de falhas e complicações ao longo do tempo, sendo necessário compreender e reduzir os fatores de risco. Este estudo prospectivo objetivou avaliar o efeito de parâmetros biomecânicos geométricos de PTFI sobre a remodelação óssea em um período de um ano de função. A amostra foi constituída por imagens de tomografia computadorizada de 48 PTFI com infraestrutura metálica e revestimento de resina acrílica em maxila e mandíbulas edentadas (21 e 27 respectivamente), totalizando 246 implantes de hexágono externo. As imagens no formato DICOM foram processadas para medir: área do polígono de sustentação, proporção coroa/implante clínica (alavanca vertical), braços de potência e de resistência antero-posteriores, distâncias de cantilever anterior e de cantilever posterior (alavancas horizontais) e o desfecho remodelação óssea peri-implantar. Os dados foram analisados por estatística descritiva e modelos multivariáveis multiníveis. Os resultados mostraram que a perda óssea média foi de 0,88mm (0,82 ± 0,94) em um ano de função. Quanto à arcada, os resultados apresentaram uma perda óssea média de 0,62mm (0,57 ± 0,67) e de 1,08mm (0,98 ± 1,18) na mandíbula e na maxila, respectivamente. Pode-se concluir que perda óssea peri-implantar aumenta com a alavanca vertical (proporção coroa/implante clínica) e o cantilever anterior tem efeito protetor na face lingual/palatina de implantes anteriores. Estas variáveis devem ser considerados no planejamento e na execução de PTFI do ponto de vista biomecânico.Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2021-11-29T20:14:42Z No. of bitstreams: 1 KAEL_SEELIG_DA_CUNHA_DIS.pdf: 3002659 bytes, checksum: cb8d13b1943a695f82662a60ebbd0981 (MD5)Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2021-11-30T19:44:35Z (GMT) No. of bitstreams: 1 KAEL_SEELIG_DA_CUNHA_DIS.pdf: 3002659 bytes, checksum: cb8d13b1943a695f82662a60ebbd0981 (MD5)Made available in DSpace on 2021-11-30T19:57:08Z (GMT). No. of bitstreams: 1 KAEL_SEELIG_DA_CUNHA_DIS.pdf: 3002659 bytes, checksum: cb8d13b1943a695f82662a60ebbd0981 (MD5) Previous issue date: 2020-02-28Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/182741/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em OdontologiaPUCRSBrasilEscola de Ciências da Saúde da VidaPerda ÓsseaBiomecânicaPrótese Dentária Fixada por ImplanteImplantes DentáriosBone lossBiomechanicsImplant-supported Dental ProsthesisCIENCIAS DA SAUDE::ODONTOLOGIAEfeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisTrabalho será publicado como artigo ou livro60 meses30/11/2026-7411869720500764667500500600-20704984698792443493590462550136975366info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSTHUMBNAILDIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.jpgDIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.jpgimage/jpeg4096http://tede2.pucrs.br/tede2/bitstream/tede/9985/4/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.jpg9b0d64ac488a54f0e6b1f05e65fd65e3MD54TEXTDIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.txtDIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.txttext/plain2755http://tede2.pucrs.br/tede2/bitstream/tede/9985/3/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.txt2c4c61b4e717c3a4229c3f693c185f93MD53ORIGINALDIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdfDIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdfapplication/pdf522325http://tede2.pucrs.br/tede2/bitstream/tede/9985/2/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf450e2ba83b5cc1e1eaa465bbdb9818e9MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-8590http://tede2.pucrs.br/tede2/bitstream/tede/9985/1/license.txt220e11f2d3ba5354f917c7035aadef24MD51tede/99852021-11-30 20:00:26.566oai:tede2.pucrs.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2021-11-30T22:00:26Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.por.fl_str_mv Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
title Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
spellingShingle Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
Cunha, Kael Seelig da
Perda Óssea
Biomecânica
Prótese Dentária Fixada por Implante
Implantes Dentários
Bone loss
Biomechanics
Implant-supported Dental Prosthesis
CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
title_full Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
title_fullStr Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
title_full_unstemmed Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
title_sort Efeito de parâmetros geométricos biomecânicos sobre a remodelação óssea peri-implantar em próteses totais fixas implantossuportadas
author Cunha, Kael Seelig da
author_facet Cunha, Kael Seelig da
author_role author
dc.contributor.advisor1.fl_str_mv Shinkai, Rosemary Sadami Arai
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3590748675382890
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/6131608503910119
dc.contributor.author.fl_str_mv Cunha, Kael Seelig da
contributor_str_mv Shinkai, Rosemary Sadami Arai
dc.subject.por.fl_str_mv Perda Óssea
Biomecânica
Prótese Dentária Fixada por Implante
Implantes Dentários
topic Perda Óssea
Biomecânica
Prótese Dentária Fixada por Implante
Implantes Dentários
Bone loss
Biomechanics
Implant-supported Dental Prosthesis
CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv Bone loss
Biomechanics
Implant-supported Dental Prosthesis
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA
description Implant-supported fixed complete dentures (PTFI) present failures and complications over time. Thus, understanding the risk factors is necessary to develop strategies to reduce them. This prospective study aimed to evaluate the effect of PTFI geometric biomechanical parameters on perimplant bone remodeling up to one year of function. The sample consisted of images of computerized tomographic exams of 48 PTFI with metallic infrastructure and acrylic resin coat in edentulous maxilla and mandible (21 e 27 respectively), totaling 246 external hexagon implants. DICOM-format images were processed to measure: supporting polygon area, clinical crown/implant ratio (vertical lever), antero-posterior power and resistance arms, of anterior cantilever and posterior cantilever distances (horizontal levers) and perimplant bone remodeling (outcome measure). Data were analyzed by descriptive statistics and multilevel multivariable models. The results exhibited average bone loss, in one year of function, correspond to 0.88mm (0,82 ± 0,94). As for the arch, the results showed average bone loss of 0,62mm (0,57 ± 0,67) and 1,08mm (0,98 ± 1,18) in mandible and maxilla, respectively. The clinical crown/implant ratio (vertical lever) and anterior cantilever (power arm of the anterior horizontal lever) had a significant effect on perimplant bone loss, according to the implant position in the arch and measuring face. It can be concluded that perimplant bone loss increases with the vertical lever (crown / clinical implant ratio) and that the anterior cantilever has a protective effect at the lingual face in anterior implants. Under the biomechanical perspective, these variables should be considered when planning and executing PTFI.
publishDate 2020
dc.date.issued.fl_str_mv 2020-02-28
dc.date.accessioned.fl_str_mv 2021-11-30T19:57:08Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://tede2.pucrs.br/tede2/handle/tede/9985
url http://tede2.pucrs.br/tede2/handle/tede/9985
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -7411869720500764667
dc.relation.confidence.fl_str_mv 500
500
600
dc.relation.cnpq.fl_str_mv -2070498469879244349
dc.relation.sponsorship.fl_str_mv 3590462550136975366
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv PUCRS
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Escola de Ciências da Saúde da Vida
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_RS
collection Biblioteca Digital de Teses e Dissertações da PUC_RS
bitstream.url.fl_str_mv http://tede2.pucrs.br/tede2/bitstream/tede/9985/4/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.jpg
http://tede2.pucrs.br/tede2/bitstream/tede/9985/3/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf.txt
http://tede2.pucrs.br/tede2/bitstream/tede/9985/2/DIS_KAEL_SEELIG_DA_CUNHA_CONFIDENCIAL.pdf
http://tede2.pucrs.br/tede2/bitstream/tede/9985/1/license.txt
bitstream.checksum.fl_str_mv 9b0d64ac488a54f0e6b1f05e65fd65e3
2c4c61b4e717c3a4229c3f693c185f93
450e2ba83b5cc1e1eaa465bbdb9818e9
220e11f2d3ba5354f917c7035aadef24
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv biblioteca.central@pucrs.br||
_version_ 1799765352879489024