Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies

Detalhes bibliográficos
Autor(a) principal: Neves, Marta M. P. S.
Data de Publicação: 2012
Outros Autores: González-García, María Begoña, Santos-Silva, Alice, Costa-García, Agustín
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.22/2022
Resumo: Antibodies against gliadin are used to detect celiac disease (CD) in patients. An electrochemical immunosensor for the voltammetric detection of human anti-gliadin antibodies (AGA) IgA and AGA IgG in real serum samples is proposed. The transducer surface consists of screen-printed carbon electrodes modified with a carbon nanotube/gold nanoparticle hybrid system, which provides a very useful surface for the amplification of the immunological interactions. The immunosensing strategy is based on the immobilization of gliadin, the antigen for the autoantibodies of interest, onto the nanostructured surface. The antigen–antibody interaction is recorded using alkaline phosphatase labeled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions (3-IP/Ag+) was used as the substrate. The analytical signal is based on the anodic redissolution of the enzymatically generated silver by cyclic voltammetry. The electrochemical behavior of this immunosensor was carefully evaluated assessing aspects as sensitivity, non-specific binding and matrix effects, and repeatability and reproducibility. The results were supported with a commercial ELISA test.
id RCAP_02849ccdc9635c64a1893f619cd42cf5
oai_identifier_str oai:recipp.ipp.pt:10400.22/2022
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodiesGliadinCeliac diseaseElectrochemical immunosensorsPoint-of-care analysisScreen-printed electrodesNanomaterialsAntibodies against gliadin are used to detect celiac disease (CD) in patients. An electrochemical immunosensor for the voltammetric detection of human anti-gliadin antibodies (AGA) IgA and AGA IgG in real serum samples is proposed. The transducer surface consists of screen-printed carbon electrodes modified with a carbon nanotube/gold nanoparticle hybrid system, which provides a very useful surface for the amplification of the immunological interactions. The immunosensing strategy is based on the immobilization of gliadin, the antigen for the autoantibodies of interest, onto the nanostructured surface. The antigen–antibody interaction is recorded using alkaline phosphatase labeled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions (3-IP/Ag+) was used as the substrate. The analytical signal is based on the anodic redissolution of the enzymatically generated silver by cyclic voltammetry. The electrochemical behavior of this immunosensor was carefully evaluated assessing aspects as sensitivity, non-specific binding and matrix effects, and repeatability and reproducibility. The results were supported with a commercial ELISA test.ElsevierRepositório Científico do Instituto Politécnico do PortoNeves, Marta M. P. S.González-García, María BegoñaSantos-Silva, AliceCosta-García, Agustín2013-09-27T11:54:31Z20122012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10400.22/2022eng0925-400510.1016/j.snb.2012.01.048metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:41:33Zoai:recipp.ipp.pt:10400.22/2022Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:23:07.994579Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
title Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
spellingShingle Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
Neves, Marta M. P. S.
Gliadin
Celiac disease
Electrochemical immunosensors
Point-of-care analysis
Screen-printed electrodes
Nanomaterials
title_short Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
title_full Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
title_fullStr Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
title_full_unstemmed Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
title_sort Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies
author Neves, Marta M. P. S.
author_facet Neves, Marta M. P. S.
González-García, María Begoña
Santos-Silva, Alice
Costa-García, Agustín
author_role author
author2 González-García, María Begoña
Santos-Silva, Alice
Costa-García, Agustín
author2_role author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Neves, Marta M. P. S.
González-García, María Begoña
Santos-Silva, Alice
Costa-García, Agustín
dc.subject.por.fl_str_mv Gliadin
Celiac disease
Electrochemical immunosensors
Point-of-care analysis
Screen-printed electrodes
Nanomaterials
topic Gliadin
Celiac disease
Electrochemical immunosensors
Point-of-care analysis
Screen-printed electrodes
Nanomaterials
description Antibodies against gliadin are used to detect celiac disease (CD) in patients. An electrochemical immunosensor for the voltammetric detection of human anti-gliadin antibodies (AGA) IgA and AGA IgG in real serum samples is proposed. The transducer surface consists of screen-printed carbon electrodes modified with a carbon nanotube/gold nanoparticle hybrid system, which provides a very useful surface for the amplification of the immunological interactions. The immunosensing strategy is based on the immobilization of gliadin, the antigen for the autoantibodies of interest, onto the nanostructured surface. The antigen–antibody interaction is recorded using alkaline phosphatase labeled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions (3-IP/Ag+) was used as the substrate. The analytical signal is based on the anodic redissolution of the enzymatically generated silver by cyclic voltammetry. The electrochemical behavior of this immunosensor was carefully evaluated assessing aspects as sensitivity, non-specific binding and matrix effects, and repeatability and reproducibility. The results were supported with a commercial ELISA test.
publishDate 2012
dc.date.none.fl_str_mv 2012
2012-01-01T00:00:00Z
2013-09-27T11:54:31Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/2022
url http://hdl.handle.net/10400.22/2022
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0925-4005
10.1016/j.snb.2012.01.048
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131326978195456