Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions

Detalhes bibliográficos
Autor(a) principal: Meireles, Susana
Data de Publicação: 2010
Outros Autores: Completo, António, Simões, José A., Flores, Paulo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/23352
Resumo: Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction in bone density in bone surrounding the implant and be related with weakness of the implant fixation, which leads to implant loosening. Several studies describe a significant decrease in postoperative bone mineral density adjacent to the joint implants, which can compromise their fixation at long term. Therefore the aim of the present study was the quantification of the strain shielding effect on the distal femur after patellofemoral arthroplasty. For this purpose three activities of daily living were considered: level walking, climbing stairs and deep bending at different angles of knee flexion. To determine the strain shielding effect, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic femurs before and after patellofemoral arthroplasty for the different daily activities. The results showed that the patellofemoral arthroplasty in general reduced the strains in the medial and distal regions of the femur for the deep bending activity occurring, consequently strain shielding effect in these regions, strain decreases of 72.0% and -67.5 % were measured. On the other side, higher values of strain were found in the anterior region after patellofemoral replacement for this activity with an increase of +182.0%. The occurrence of strain shielding looks more important when the angle of knee flexion and applied load increase. The strain shielding and over-loading may have relevant effects on bone remodeling surrounding the patellofemoral implant, suggesting a potential effect of later bone resorption in the medial and distal femur regions in case of a great frequency of the deep bending activity.
id RCAP_0329c12721acf9353df6458fdba5e06f
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/23352
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditionsPatellofemoral arthroplastyStrain shieldingExperimental strainsPatellofemoral prosthesisStrain gauge measurementsScience & TechnologyStrain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction in bone density in bone surrounding the implant and be related with weakness of the implant fixation, which leads to implant loosening. Several studies describe a significant decrease in postoperative bone mineral density adjacent to the joint implants, which can compromise their fixation at long term. Therefore the aim of the present study was the quantification of the strain shielding effect on the distal femur after patellofemoral arthroplasty. For this purpose three activities of daily living were considered: level walking, climbing stairs and deep bending at different angles of knee flexion. To determine the strain shielding effect, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic femurs before and after patellofemoral arthroplasty for the different daily activities. The results showed that the patellofemoral arthroplasty in general reduced the strains in the medial and distal regions of the femur for the deep bending activity occurring, consequently strain shielding effect in these regions, strain decreases of 72.0% and -67.5 % were measured. On the other side, higher values of strain were found in the anterior region after patellofemoral replacement for this activity with an increase of +182.0%. The occurrence of strain shielding looks more important when the angle of knee flexion and applied load increase. The strain shielding and over-loading may have relevant effects on bone remodeling surrounding the patellofemoral implant, suggesting a potential effect of later bone resorption in the medial and distal femur regions in case of a great frequency of the deep bending activity.Fundação para a Ciência e a Tecnologia (FCT)ElsevierUniversidade do MinhoMeireles, SusanaCompleto, AntónioSimões, José A.Flores, Paulo20102010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/23352eng0021-929010.1016/j.jbiomech.2009.09.04820004900info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:10:24Zoai:repositorium.sdum.uminho.pt:1822/23352Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:02:00.317421Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
title Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
spellingShingle Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
Meireles, Susana
Patellofemoral arthroplasty
Strain shielding
Experimental strains
Patellofemoral prosthesis
Strain gauge measurements
Science & Technology
title_short Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
title_full Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
title_fullStr Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
title_full_unstemmed Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
title_sort Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions
author Meireles, Susana
author_facet Meireles, Susana
Completo, António
Simões, José A.
Flores, Paulo
author_role author
author2 Completo, António
Simões, José A.
Flores, Paulo
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Meireles, Susana
Completo, António
Simões, José A.
Flores, Paulo
dc.subject.por.fl_str_mv Patellofemoral arthroplasty
Strain shielding
Experimental strains
Patellofemoral prosthesis
Strain gauge measurements
Science & Technology
topic Patellofemoral arthroplasty
Strain shielding
Experimental strains
Patellofemoral prosthesis
Strain gauge measurements
Science & Technology
description Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction in bone density in bone surrounding the implant and be related with weakness of the implant fixation, which leads to implant loosening. Several studies describe a significant decrease in postoperative bone mineral density adjacent to the joint implants, which can compromise their fixation at long term. Therefore the aim of the present study was the quantification of the strain shielding effect on the distal femur after patellofemoral arthroplasty. For this purpose three activities of daily living were considered: level walking, climbing stairs and deep bending at different angles of knee flexion. To determine the strain shielding effect, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic femurs before and after patellofemoral arthroplasty for the different daily activities. The results showed that the patellofemoral arthroplasty in general reduced the strains in the medial and distal regions of the femur for the deep bending activity occurring, consequently strain shielding effect in these regions, strain decreases of 72.0% and -67.5 % were measured. On the other side, higher values of strain were found in the anterior region after patellofemoral replacement for this activity with an increase of +182.0%. The occurrence of strain shielding looks more important when the angle of knee flexion and applied load increase. The strain shielding and over-loading may have relevant effects on bone remodeling surrounding the patellofemoral implant, suggesting a potential effect of later bone resorption in the medial and distal femur regions in case of a great frequency of the deep bending activity.
publishDate 2010
dc.date.none.fl_str_mv 2010
2010-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/23352
url http://hdl.handle.net/1822/23352
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0021-9290
10.1016/j.jbiomech.2009.09.048
20004900
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132420405985280