Driftless gas proportional scintillation counter pulse analysis using digital processing techniques

Detalhes bibliográficos
Autor(a) principal: Simões, P. C. P. S.
Data de Publicação: 2001
Outros Autores: Santos, J. M. F. dos, Conde, C. A. N.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/8211
https://doi.org/10.1002/xrs.508
Resumo: A driftless gas proportional scintillation counter (GPSC) of simple design, using digital pulse-signature analysis, is described. The digital pulse acquisition and processing techniques are shown to be a simple and effective method to determine pulse time duration and to perform pulse amplitude correction in driftless GPSCs. This technique allows the application of driftless GPSCs to x-ray spectrometry up to 60 keV. Although the pulse throughput achieved by the digital pulse-height analyser in this application is limited to about 2 kHz, total interaction rates above 20 kHz can be tolerated by the detector without significant degradation of the pulse-height distributions obtained. Copyright © 2001 John Wiley & Sons, Ltd.
id RCAP_03b48beb6d8c6efb8ad00ed42c50ac51
oai_identifier_str oai:estudogeral.uc.pt:10316/8211
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Driftless gas proportional scintillation counter pulse analysis using digital processing techniquesA driftless gas proportional scintillation counter (GPSC) of simple design, using digital pulse-signature analysis, is described. The digital pulse acquisition and processing techniques are shown to be a simple and effective method to determine pulse time duration and to perform pulse amplitude correction in driftless GPSCs. This technique allows the application of driftless GPSCs to x-ray spectrometry up to 60 keV. Although the pulse throughput achieved by the digital pulse-height analyser in this application is limited to about 2 kHz, total interaction rates above 20 kHz can be tolerated by the detector without significant degradation of the pulse-height distributions obtained. Copyright © 2001 John Wiley & Sons, Ltd.2001info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/8211http://hdl.handle.net/10316/8211https://doi.org/10.1002/xrs.508engX-Ray Spectrometry. 30:5 (2001) 342-347Simões, P. C. P. S.Santos, J. M. F. dosConde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-10-22T09:44:07Zoai:estudogeral.uc.pt:10316/8211Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:41.081294Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
title Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
spellingShingle Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
Simões, P. C. P. S.
title_short Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
title_full Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
title_fullStr Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
title_full_unstemmed Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
title_sort Driftless gas proportional scintillation counter pulse analysis using digital processing techniques
author Simões, P. C. P. S.
author_facet Simões, P. C. P. S.
Santos, J. M. F. dos
Conde, C. A. N.
author_role author
author2 Santos, J. M. F. dos
Conde, C. A. N.
author2_role author
author
dc.contributor.author.fl_str_mv Simões, P. C. P. S.
Santos, J. M. F. dos
Conde, C. A. N.
description A driftless gas proportional scintillation counter (GPSC) of simple design, using digital pulse-signature analysis, is described. The digital pulse acquisition and processing techniques are shown to be a simple and effective method to determine pulse time duration and to perform pulse amplitude correction in driftless GPSCs. This technique allows the application of driftless GPSCs to x-ray spectrometry up to 60 keV. Although the pulse throughput achieved by the digital pulse-height analyser in this application is limited to about 2 kHz, total interaction rates above 20 kHz can be tolerated by the detector without significant degradation of the pulse-height distributions obtained. Copyright © 2001 John Wiley & Sons, Ltd.
publishDate 2001
dc.date.none.fl_str_mv 2001
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/8211
http://hdl.handle.net/10316/8211
https://doi.org/10.1002/xrs.508
url http://hdl.handle.net/10316/8211
https://doi.org/10.1002/xrs.508
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv X-Ray Spectrometry. 30:5 (2001) 342-347
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133888254050304