Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/5153 https://doi.org/10.1016/S0039-9140(03)00327-8 |
Resumo: | A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 [Omega]. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated. |
id |
RCAP_06c6d333846867558c07c40603fb9e45 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/5153 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodesManganeseTrace metalsCathodic stripping voltammetryChronoamperometryA sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 [Omega]. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.http://www.sciencedirect.com/science/article/B6THP-492099M-1/1/29b524aa23afb3664d14b92c34f681b02003info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5153http://hdl.handle.net/10316/5153https://doi.org/10.1016/S0039-9140(03)00327-8engTalanta. 61:5 (2003) 643-650Filipe, Olga M. S.Brett, Christopher M. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T16:59:33Zoai:estudogeral.uc.pt:10316/5153Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:19.911074Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
title |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
spellingShingle |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes Filipe, Olga M. S. Manganese Trace metals Cathodic stripping voltammetry Chronoamperometry |
title_short |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
title_full |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
title_fullStr |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
title_full_unstemmed |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
title_sort |
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes |
author |
Filipe, Olga M. S. |
author_facet |
Filipe, Olga M. S. Brett, Christopher M. A. |
author_role |
author |
author2 |
Brett, Christopher M. A. |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Filipe, Olga M. S. Brett, Christopher M. A. |
dc.subject.por.fl_str_mv |
Manganese Trace metals Cathodic stripping voltammetry Chronoamperometry |
topic |
Manganese Trace metals Cathodic stripping voltammetry Chronoamperometry |
description |
A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 [Omega]. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/5153 http://hdl.handle.net/10316/5153 https://doi.org/10.1016/S0039-9140(03)00327-8 |
url |
http://hdl.handle.net/10316/5153 https://doi.org/10.1016/S0039-9140(03)00327-8 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Talanta. 61:5 (2003) 643-650 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133905243078656 |