Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes

Detalhes bibliográficos
Autor(a) principal: Filipe, Olga M. S.
Data de Publicação: 2003
Outros Autores: Brett, Christopher M. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/5153
https://doi.org/10.1016/S0039-9140(03)00327-8
Resumo: A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 [Omega]. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.
id RCAP_06c6d333846867558c07c40603fb9e45
oai_identifier_str oai:estudogeral.uc.pt:10316/5153
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodesManganeseTrace metalsCathodic stripping voltammetryChronoamperometryA sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 [Omega]. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.http://www.sciencedirect.com/science/article/B6THP-492099M-1/1/29b524aa23afb3664d14b92c34f681b02003info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5153http://hdl.handle.net/10316/5153https://doi.org/10.1016/S0039-9140(03)00327-8engTalanta. 61:5 (2003) 643-650Filipe, Olga M. S.Brett, Christopher M. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T16:59:33Zoai:estudogeral.uc.pt:10316/5153Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:19.911074Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
title Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
spellingShingle Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
Filipe, Olga M. S.
Manganese
Trace metals
Cathodic stripping voltammetry
Chronoamperometry
title_short Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
title_full Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
title_fullStr Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
title_full_unstemmed Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
title_sort Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes
author Filipe, Olga M. S.
author_facet Filipe, Olga M. S.
Brett, Christopher M. A.
author_role author
author2 Brett, Christopher M. A.
author2_role author
dc.contributor.author.fl_str_mv Filipe, Olga M. S.
Brett, Christopher M. A.
dc.subject.por.fl_str_mv Manganese
Trace metals
Cathodic stripping voltammetry
Chronoamperometry
topic Manganese
Trace metals
Cathodic stripping voltammetry
Chronoamperometry
description A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 [Omega]. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.
publishDate 2003
dc.date.none.fl_str_mv 2003
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/5153
http://hdl.handle.net/10316/5153
https://doi.org/10.1016/S0039-9140(03)00327-8
url http://hdl.handle.net/10316/5153
https://doi.org/10.1016/S0039-9140(03)00327-8
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Talanta. 61:5 (2003) 643-650
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133905243078656