One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study

Detalhes bibliográficos
Autor(a) principal: Moreira, Filipe
Data de Publicação: 2021
Outros Autores: Rocha, Salomão José Coelho Silva, Caramelo, Francisco, Tondela, João P.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/105216
https://doi.org/10.3390/ma14154179
Resumo: Objective: To evaluate the peri-implant hard tissue change at 6 and 12 months after implant placement between definitive abutment placed at the same time of implant surgery, never removing it, and healing abutment disconnected and reconnected three times until the placement of the final rehabilitation. Material and methods: Each partial edentulous patient could receive between 1 and 4 platform-switched implants in the posterior regions. If the implants had primary stability—implant stability quotient (ISQ) equal to or greater than 50, they were randomized to the test group with the abutment inserted at the same time of implant placement (DA) or to the control group, receiving a healing abutment (PA). At 6 and 12 months after surgery, data related with vertical bone level changes (primary outcome) and other clinical parameters (implant mobility, bleeding on probing, probing depth, plaque index) were assessed. Results: 53 implants were included in the trial and completed 12 months follow-up (overall survival rate: 100%). All implants achieved primary stability, with an average ISQ value of 80.9 on the day of surgery. From surgery to 6 months, the mean bone loss was 0.14 0.18 mm for the DA group and 0.23 0.29 mm for the PA group, without statistical significance difference. Between 6 and 12 months, the mean bone loss was 0.14 0.21 mm for the DA group and 0.21 0.27 mm for the PA group, also without statistical significance between the two groups. There were no statistically significant differences (p = 0.330) in total bone loss after 12 months between the control and the study groups. Conclusions: The one abutment one time protocol has at least an equivalent effect on the peri-implant bone level changes when compared with the use of healing abutments that are disconnected and reconnected at least three times.
id RCAP_07de5b54ea186e168c7f159a2b2874bc
oai_identifier_str oai:estudogeral.uc.pt:10316/105216
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Studyone abutment one timeimplant–abutment connectionmarginal bone lossrepeated abutment disconnectionObjective: To evaluate the peri-implant hard tissue change at 6 and 12 months after implant placement between definitive abutment placed at the same time of implant surgery, never removing it, and healing abutment disconnected and reconnected three times until the placement of the final rehabilitation. Material and methods: Each partial edentulous patient could receive between 1 and 4 platform-switched implants in the posterior regions. If the implants had primary stability—implant stability quotient (ISQ) equal to or greater than 50, they were randomized to the test group with the abutment inserted at the same time of implant placement (DA) or to the control group, receiving a healing abutment (PA). At 6 and 12 months after surgery, data related with vertical bone level changes (primary outcome) and other clinical parameters (implant mobility, bleeding on probing, probing depth, plaque index) were assessed. Results: 53 implants were included in the trial and completed 12 months follow-up (overall survival rate: 100%). All implants achieved primary stability, with an average ISQ value of 80.9 on the day of surgery. From surgery to 6 months, the mean bone loss was 0.14 0.18 mm for the DA group and 0.23 0.29 mm for the PA group, without statistical significance difference. Between 6 and 12 months, the mean bone loss was 0.14 0.21 mm for the DA group and 0.21 0.27 mm for the PA group, also without statistical significance between the two groups. There were no statistically significant differences (p = 0.330) in total bone loss after 12 months between the control and the study groups. Conclusions: The one abutment one time protocol has at least an equivalent effect on the peri-implant bone level changes when compared with the use of healing abutments that are disconnected and reconnected at least three times.MDPI AG2021-07-27info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/105216http://hdl.handle.net/10316/105216https://doi.org/10.3390/ma14154179eng1996-1944Moreira, FilipeRocha, Salomão José Coelho SilvaCaramelo, FranciscoTondela, João P.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-02-09T11:44:11Zoai:estudogeral.uc.pt:10316/105216Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:21:49.179424Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
title One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
spellingShingle One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
Moreira, Filipe
one abutment one time
implant–abutment connection
marginal bone loss
repeated abutment disconnection
title_short One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
title_full One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
title_fullStr One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
title_full_unstemmed One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
title_sort One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
author Moreira, Filipe
author_facet Moreira, Filipe
Rocha, Salomão José Coelho Silva
Caramelo, Francisco
Tondela, João P.
author_role author
author2 Rocha, Salomão José Coelho Silva
Caramelo, Francisco
Tondela, João P.
author2_role author
author
author
dc.contributor.author.fl_str_mv Moreira, Filipe
Rocha, Salomão José Coelho Silva
Caramelo, Francisco
Tondela, João P.
dc.subject.por.fl_str_mv one abutment one time
implant–abutment connection
marginal bone loss
repeated abutment disconnection
topic one abutment one time
implant–abutment connection
marginal bone loss
repeated abutment disconnection
description Objective: To evaluate the peri-implant hard tissue change at 6 and 12 months after implant placement between definitive abutment placed at the same time of implant surgery, never removing it, and healing abutment disconnected and reconnected three times until the placement of the final rehabilitation. Material and methods: Each partial edentulous patient could receive between 1 and 4 platform-switched implants in the posterior regions. If the implants had primary stability—implant stability quotient (ISQ) equal to or greater than 50, they were randomized to the test group with the abutment inserted at the same time of implant placement (DA) or to the control group, receiving a healing abutment (PA). At 6 and 12 months after surgery, data related with vertical bone level changes (primary outcome) and other clinical parameters (implant mobility, bleeding on probing, probing depth, plaque index) were assessed. Results: 53 implants were included in the trial and completed 12 months follow-up (overall survival rate: 100%). All implants achieved primary stability, with an average ISQ value of 80.9 on the day of surgery. From surgery to 6 months, the mean bone loss was 0.14 0.18 mm for the DA group and 0.23 0.29 mm for the PA group, without statistical significance difference. Between 6 and 12 months, the mean bone loss was 0.14 0.21 mm for the DA group and 0.21 0.27 mm for the PA group, also without statistical significance between the two groups. There were no statistically significant differences (p = 0.330) in total bone loss after 12 months between the control and the study groups. Conclusions: The one abutment one time protocol has at least an equivalent effect on the peri-implant bone level changes when compared with the use of healing abutments that are disconnected and reconnected at least three times.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-27
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/105216
http://hdl.handle.net/10316/105216
https://doi.org/10.3390/ma14154179
url http://hdl.handle.net/10316/105216
https://doi.org/10.3390/ma14154179
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1996-1944
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv MDPI AG
publisher.none.fl_str_mv MDPI AG
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134108782166016