Resumo: This paper addresses the significant need for improvements in device version reporting and practice across the academic and technical activity monitoring literature, and it recommends assessments for new and updated consumer sensing devices. Reproducibility and data veracity are central to good scholarship, and particularly significant in clinical and health applications. Across the literature there is an absence of device version reporting and a failure to recognize that device validity is not maintained when firmware and software updates can, and do, change device performance and parameter estimation. In this paper, we propose the use of tractable methods to assess devices at their current version and provide an example empirical approach. Experimental results for heart rate and step count acquisitions during walking and everyday living activities from Garmin Vivosmart 3 (v4.10) wristband monitors are presented and analyzed, and the reliability issues of optically-acquired heart rates, especially during periods of activity, are demonstrated and discussed. In conclusion, the paper recommends the empirical assessment of new and updated activity monitors and improvements in device version reporting across the academic and technical literature.
id RCAP_0a98fb6b525bea27874d07e4c30b31f4
oai_identifier_str oai:ubibliorum.ubi.pt:10400.6/8253
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate MonitorsAccelerometryActivities of Daily LivingAdultExercise TestFemaleHeart RateHumansMaleMiddle AgedMonitoringWalkingWearable Electronic DevicesThis paper addresses the significant need for improvements in device version reporting and practice across the academic and technical activity monitoring literature, and it recommends assessments for new and updated consumer sensing devices. Reproducibility and data veracity are central to good scholarship, and particularly significant in clinical and health applications. Across the literature there is an absence of device version reporting and a failure to recognize that device validity is not maintained when firmware and software updates can, and do, change device performance and parameter estimation. In this paper, we propose the use of tractable methods to assess devices at their current version and provide an example empirical approach. Experimental results for heart rate and step count acquisitions during walking and everyday living activities from Garmin Vivosmart 3 (v4.10) wristband monitors are presented and analyzed, and the reliability issues of optically-acquired heart rates, especially during periods of activity, are demonstrated and discussed. In conclusion, the paper recommends the empirical assessment of new and updated activity monitors and improvements in device version reporting across the academic and technical literature.uBibliorumCollins, TimWoolley, SandraOniani, SalomePires, IvanGarcia, Nuno M.Ledger, SeanPandyan, Anand2020-01-14T12:28:31Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/8253eng10.3390/s19071705info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-15T09:48:07Zoai:ubibliorum.ubi.pt:10400.6/8253Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:48:37.746708Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
title Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
spellingShingle Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
Collins, Tim
Accelerometry
Activities of Daily Living
Adult
Exercise Test
Female
Heart Rate
Humans
Male
Middle Aged
Monitoring
Walking
Wearable Electronic Devices
title_short Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
title_full Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
title_fullStr Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
title_full_unstemmed Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
title_sort Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors
author Collins, Tim
author_facet Collins, Tim
Woolley, Sandra
Oniani, Salome
Pires, Ivan
Garcia, Nuno M.
Ledger, Sean
Pandyan, Anand
author_role author
author2 Woolley, Sandra
Oniani, Salome
Pires, Ivan
Garcia, Nuno M.
Ledger, Sean
Pandyan, Anand
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv uBibliorum
dc.contributor.author.fl_str_mv Collins, Tim
Woolley, Sandra
Oniani, Salome
Pires, Ivan
Garcia, Nuno M.
Ledger, Sean
Pandyan, Anand
dc.subject.por.fl_str_mv Accelerometry
Activities of Daily Living
Adult
Exercise Test
Female
Heart Rate
Humans
Male
Middle Aged
Monitoring
Walking
Wearable Electronic Devices
topic Accelerometry
Activities of Daily Living
Adult
Exercise Test
Female
Heart Rate
Humans
Male
Middle Aged
Monitoring
Walking
Wearable Electronic Devices
description This paper addresses the significant need for improvements in device version reporting and practice across the academic and technical activity monitoring literature, and it recommends assessments for new and updated consumer sensing devices. Reproducibility and data veracity are central to good scholarship, and particularly significant in clinical and health applications. Across the literature there is an absence of device version reporting and a failure to recognize that device validity is not maintained when firmware and software updates can, and do, change device performance and parameter estimation. In this paper, we propose the use of tractable methods to assess devices at their current version and provide an example empirical approach. Experimental results for heart rate and step count acquisitions during walking and everyday living activities from Garmin Vivosmart 3 (v4.10) wristband monitors are presented and analyzed, and the reliability issues of optically-acquired heart rates, especially during periods of activity, are demonstrated and discussed. In conclusion, the paper recommends the empirical assessment of new and updated activity monitors and improvements in device version reporting across the academic and technical literature.
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01T00:00:00Z
2020-01-14T12:28:31Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.6/8253
url http://hdl.handle.net/10400.6/8253
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.3390/s19071705
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136380242100224