Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength

Detalhes bibliográficos
Autor(a) principal: Sousa, António Carlos
Data de Publicação: 2022
Outros Autores: Marques, Diogo Luís, Calado, António Manuel, Pacheco, Carlos, Marinho, Daniel, Marques, Mário Cardoso, Travassos, Bruno
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.6/12394
Resumo: We analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength.
id RCAP_1113dd027e4d74dbab60098860dfcc4e
oai_identifier_str oai:ubibliorum.ubi.pt:10400.6/12394
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction StrengthPortable dynamometerGroinWe analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength.This research was funded under the NANOSTIMA project Macro-to-Nano Human Sensing: Towards Integrated Multimodal Health Monitoring and Analytics of operation NORTE-01-0145-FEDER-000016, co-financed by the European Regional Development Fund (ERDF) through the NORTE 2020 (North Regional Operational Program 2014/2020) and supported by the Portuguese Foundation for Science and Technology, I.P., grant number UID04045/2020, Portugal. Diogo Luís Marques is funded by the Portuguese Foundation for Science and Technology, grant number SFRH/BD/147608/2019.uBibliorumSousa, António CarlosMarques, Diogo LuísCalado, António ManuelPacheco, CarlosMarinho, DanielMarques, Mário CardosoTravassos, Bruno2022-11-21T09:51:38Z2022-04-012022-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/12394eng10.2478/hukin-2022-0029info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-15T09:55:33Zoai:ubibliorum.ubi.pt:10400.6/12394Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:52:00.704445Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
title Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
spellingShingle Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
Sousa, António Carlos
Portable dynamometer
Groin
title_short Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
title_full Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
title_fullStr Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
title_full_unstemmed Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
title_sort Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength
author Sousa, António Carlos
author_facet Sousa, António Carlos
Marques, Diogo Luís
Calado, António Manuel
Pacheco, Carlos
Marinho, Daniel
Marques, Mário Cardoso
Travassos, Bruno
author_role author
author2 Marques, Diogo Luís
Calado, António Manuel
Pacheco, Carlos
Marinho, Daniel
Marques, Mário Cardoso
Travassos, Bruno
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv uBibliorum
dc.contributor.author.fl_str_mv Sousa, António Carlos
Marques, Diogo Luís
Calado, António Manuel
Pacheco, Carlos
Marinho, Daniel
Marques, Mário Cardoso
Travassos, Bruno
dc.subject.por.fl_str_mv Portable dynamometer
Groin
topic Portable dynamometer
Groin
description We analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength.
publishDate 2022
dc.date.none.fl_str_mv 2022-11-21T09:51:38Z
2022-04-01
2022-04-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.6/12394
url http://hdl.handle.net/10400.6/12394
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.2478/hukin-2022-0029
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136408760221696