Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/52756 |
Resumo: | PURPOSE. This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: Clix (R), Dalbo-Plus (R) and Locator (R). In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37 degrees C. The abutments were placed at angulations of 0 degrees, 10 degrees and 20 degrees. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F ((2.48)) = 343619, P<.05) and the type of attachment (F ((7.48)) = 23.220, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments. |
id |
RCAP_116db9c11ff8de3833d19ae296c5aaa1 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/52756 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro studyDental implantsEdentulous patientsOverdenturesAttachmentsScience & TechnologyPURPOSE. This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: Clix (R), Dalbo-Plus (R) and Locator (R). In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37 degrees C. The abutments were placed at angulations of 0 degrees, 10 degrees and 20 degrees. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F ((2.48)) = 343619, P<.05) and the type of attachment (F ((7.48)) = 23.220, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.info:eu-repo/semantics/publishedVersionThe Korean Academy of ProsthodonticsUniversidade do MinhoAroso, CarlosSilva, Antonio SergioUstrell, RaulMendes, Jose ManuelBraga, A. C.Berastegui, EstherEscuin, Tomas2016-02-012016-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/52756eng2005-780610.4047/jap.2016.8.1.21info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:48:17Zoai:repositorium.sdum.uminho.pt:1822/52756Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:46:28.871370Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
title |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
spellingShingle |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study Aroso, Carlos Dental implants Edentulous patients Overdentures Attachments Science & Technology |
title_short |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
title_full |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
title_fullStr |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
title_full_unstemmed |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
title_sort |
Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study |
author |
Aroso, Carlos |
author_facet |
Aroso, Carlos Silva, Antonio Sergio Ustrell, Raul Mendes, Jose Manuel Braga, A. C. Berastegui, Esther Escuin, Tomas |
author_role |
author |
author2 |
Silva, Antonio Sergio Ustrell, Raul Mendes, Jose Manuel Braga, A. C. Berastegui, Esther Escuin, Tomas |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Aroso, Carlos Silva, Antonio Sergio Ustrell, Raul Mendes, Jose Manuel Braga, A. C. Berastegui, Esther Escuin, Tomas |
dc.subject.por.fl_str_mv |
Dental implants Edentulous patients Overdentures Attachments Science & Technology |
topic |
Dental implants Edentulous patients Overdentures Attachments Science & Technology |
description |
PURPOSE. This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: Clix (R), Dalbo-Plus (R) and Locator (R). In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37 degrees C. The abutments were placed at angulations of 0 degrees, 10 degrees and 20 degrees. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F ((2.48)) = 343619, P<.05) and the type of attachment (F ((7.48)) = 23.220, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-02-01 2016-02-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/52756 |
url |
http://hdl.handle.net/1822/52756 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2005-7806 10.4047/jap.2016.8.1.21 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
The Korean Academy of Prosthodontics |
publisher.none.fl_str_mv |
The Korean Academy of Prosthodontics |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133033745350656 |