Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations

Detalhes bibliográficos
Autor(a) principal: Maria de Lurdes Lopes
Data de Publicação: 2020
Outros Autores: Fernando Luiz Lavoie, Marcelo Kobelnik, Clever Aparecido Valentin, Jefferson Lins da Silva
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/10216/129034
Resumo: This paper analyzed the behavior of an HDPE geomembrane exhumed sample used for 2.25 years as a liner in an industrial water pond from a Brazilian company, as well as another similar sample as a reference. The thermogravimetry (TG) using different heating rates under synthetic air purge gas evaluation showed that the exhumed sample presented a different behavior in the TG curve for a heating rate of 5 C min-1 attributed to the reaction time. The thermomechanical analysis (TMA) curves without purge gas showed the range of thermal stability between 30 and 65 C for the reference sample, which is attributed to a molecular relaxation. The exhumed sample does not have the same relaxation, probably because this sample was submitted to severe environmental conditions in the field. Finally, the physical property values for the exhumed sample showed mechanical brittle behavior, which can indicate that changes probably occurred in the polymer structure.
id RCAP_1395f3cfd945fa815d575cdbb93367e2
oai_identifier_str oai:repositorio-aberto.up.pt:10216/129034
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisationsCiências Tecnológicas, Ciências da engenharia e tecnologiasTechnological sciences, Engineering and technologyThis paper analyzed the behavior of an HDPE geomembrane exhumed sample used for 2.25 years as a liner in an industrial water pond from a Brazilian company, as well as another similar sample as a reference. The thermogravimetry (TG) using different heating rates under synthetic air purge gas evaluation showed that the exhumed sample presented a different behavior in the TG curve for a heating rate of 5 C min-1 attributed to the reaction time. The thermomechanical analysis (TMA) curves without purge gas showed the range of thermal stability between 30 and 65 C for the reference sample, which is attributed to a molecular relaxation. The exhumed sample does not have the same relaxation, probably because this sample was submitted to severe environmental conditions in the field. Finally, the physical property values for the exhumed sample showed mechanical brittle behavior, which can indicate that changes probably occurred in the polymer structure.20202020-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/10216/129034eng2590-048X10.1016/j.rinma.2020.100131Maria de Lurdes LopesFernando Luiz LavoieMarcelo KobelnikClever Aparecido ValentinJefferson Lins da Silvainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T14:47:59Zoai:repositorio-aberto.up.pt:10216/129034Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:08:44.919366Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
title Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
spellingShingle Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
Maria de Lurdes Lopes
Ciências Tecnológicas, Ciências da engenharia e tecnologias
Technological sciences, Engineering and technology
title_short Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
title_full Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
title_fullStr Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
title_full_unstemmed Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
title_sort Study of an exhumed HDPE geomembrane used in an industrial water pond: physical and thermoanalytical characterisations
author Maria de Lurdes Lopes
author_facet Maria de Lurdes Lopes
Fernando Luiz Lavoie
Marcelo Kobelnik
Clever Aparecido Valentin
Jefferson Lins da Silva
author_role author
author2 Fernando Luiz Lavoie
Marcelo Kobelnik
Clever Aparecido Valentin
Jefferson Lins da Silva
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Maria de Lurdes Lopes
Fernando Luiz Lavoie
Marcelo Kobelnik
Clever Aparecido Valentin
Jefferson Lins da Silva
dc.subject.por.fl_str_mv Ciências Tecnológicas, Ciências da engenharia e tecnologias
Technological sciences, Engineering and technology
topic Ciências Tecnológicas, Ciências da engenharia e tecnologias
Technological sciences, Engineering and technology
description This paper analyzed the behavior of an HDPE geomembrane exhumed sample used for 2.25 years as a liner in an industrial water pond from a Brazilian company, as well as another similar sample as a reference. The thermogravimetry (TG) using different heating rates under synthetic air purge gas evaluation showed that the exhumed sample presented a different behavior in the TG curve for a heating rate of 5 C min-1 attributed to the reaction time. The thermomechanical analysis (TMA) curves without purge gas showed the range of thermal stability between 30 and 65 C for the reference sample, which is attributed to a molecular relaxation. The exhumed sample does not have the same relaxation, probably because this sample was submitted to severe environmental conditions in the field. Finally, the physical property values for the exhumed sample showed mechanical brittle behavior, which can indicate that changes probably occurred in the polymer structure.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/129034
url https://hdl.handle.net/10216/129034
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2590-048X
10.1016/j.rinma.2020.100131
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136012828409857