Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws

Detalhes bibliográficos
Autor(a) principal: Astudillo, Joel Luan de Racskai Robert
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10362/73718
Resumo: Current medical implant spinal screws rely on a thin Hydroxyapatite layer to im-prove bone-implant fixation, however this coating presents weak mechanical strength performance. Recent advances in materials science research have explored the production of composite coating for the use in medical implant coatings industry. This new field of composite engineering approaches, enabled a promising cheaper and improved alter-native to current production methods using solely Hydroxyapatite. CERAMED S.A. in-terest on developing new upgraded and cheaper Atmospheric Plasma Spray coatings culminated on this work where it was manufactured by Turbula mixing a composite pow-der for J3 at 101 RPM, using known at the time of this study available commercial pow-ders of Titanium and Hydroxyapatite of size range [5-200] and [15-200] μm respectively and density 4,522 and 3,148 g/cm3 respectively. This composite powder is used trough an Atmospheric Plasma Spray system to transform it into a coating hard coating for spe-cific use in stainless steel type 316 implant spinal screws. Based on previous literature and available equipment and materials at CERAMED S.A. facilities, an Atmospheric Plasma Spray program 1 was created. A preliminary study using, pre-selected primary parameters was made to understand the direct influence of Atmospheric Plasma spray system parameters, on coating properties like thickness, pull-out strength, coating crys-tallinity and roughness. The coating showed good results on pull out strength on trough a wide set of ranges showing an improved adhesion strength compared to Hydroxyap-atite, however crystallinity presented results under the required for commercial usage. Using 4 main primary Plasma Spray system factors (Nozzle Distance, Plasma Power, Primary Gas Flow and Secondary Gas Flow), a Design of experiments using 2 best lev-els within the range. By using a full factorial study design of experiences an analysis of variance was performed and the best set of levels for each factor was calculated. Pre-dicted range of results showed to be close to standard requirements but not in compli-ance, between [34,16- 39,66] % of crystallinity. A confirmation experience was per-formed using the best levels for crystallinity with a value of 34,31% and adhesion strength of the coating showed a value of 18,89 ± 3,76 MPa, considerably above the values for single HAp.
id RCAP_13f461d73a88a55330e0a99ef707c46f
oai_identifier_str oai:run.unl.pt:10362/73718
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screwsDomínio/Área Científica::Engenharia e Tecnologia::Engenharia dos MateriaisCurrent medical implant spinal screws rely on a thin Hydroxyapatite layer to im-prove bone-implant fixation, however this coating presents weak mechanical strength performance. Recent advances in materials science research have explored the production of composite coating for the use in medical implant coatings industry. This new field of composite engineering approaches, enabled a promising cheaper and improved alter-native to current production methods using solely Hydroxyapatite. CERAMED S.A. in-terest on developing new upgraded and cheaper Atmospheric Plasma Spray coatings culminated on this work where it was manufactured by Turbula mixing a composite pow-der for J3 at 101 RPM, using known at the time of this study available commercial pow-ders of Titanium and Hydroxyapatite of size range [5-200] and [15-200] μm respectively and density 4,522 and 3,148 g/cm3 respectively. This composite powder is used trough an Atmospheric Plasma Spray system to transform it into a coating hard coating for spe-cific use in stainless steel type 316 implant spinal screws. Based on previous literature and available equipment and materials at CERAMED S.A. facilities, an Atmospheric Plasma Spray program 1 was created. A preliminary study using, pre-selected primary parameters was made to understand the direct influence of Atmospheric Plasma spray system parameters, on coating properties like thickness, pull-out strength, coating crys-tallinity and roughness. The coating showed good results on pull out strength on trough a wide set of ranges showing an improved adhesion strength compared to Hydroxyap-atite, however crystallinity presented results under the required for commercial usage. Using 4 main primary Plasma Spray system factors (Nozzle Distance, Plasma Power, Primary Gas Flow and Secondary Gas Flow), a Design of experiments using 2 best lev-els within the range. By using a full factorial study design of experiences an analysis of variance was performed and the best set of levels for each factor was calculated. Pre-dicted range of results showed to be close to standard requirements but not in compli-ance, between [34,16- 39,66] % of crystallinity. A confirmation experience was per-formed using the best levels for crystallinity with a value of 34,31% and adhesion strength of the coating showed a value of 18,89 ± 3,76 MPa, considerably above the values for single HAp.Pires, EduardoBorges, JoãoRUNAstudillo, Joel Luan de Racskai Robert2021-04-08T00:30:55Z2019-05-2920192019-05-29T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10362/73718enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T04:33:55Zoai:run.unl.pt:10362/73718Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:35:18.286865Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
title Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
spellingShingle Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
Astudillo, Joel Luan de Racskai Robert
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia dos Materiais
title_short Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
title_full Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
title_fullStr Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
title_full_unstemmed Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
title_sort Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws
author Astudillo, Joel Luan de Racskai Robert
author_facet Astudillo, Joel Luan de Racskai Robert
author_role author
dc.contributor.none.fl_str_mv Pires, Eduardo
Borges, João
RUN
dc.contributor.author.fl_str_mv Astudillo, Joel Luan de Racskai Robert
dc.subject.por.fl_str_mv Domínio/Área Científica::Engenharia e Tecnologia::Engenharia dos Materiais
topic Domínio/Área Científica::Engenharia e Tecnologia::Engenharia dos Materiais
description Current medical implant spinal screws rely on a thin Hydroxyapatite layer to im-prove bone-implant fixation, however this coating presents weak mechanical strength performance. Recent advances in materials science research have explored the production of composite coating for the use in medical implant coatings industry. This new field of composite engineering approaches, enabled a promising cheaper and improved alter-native to current production methods using solely Hydroxyapatite. CERAMED S.A. in-terest on developing new upgraded and cheaper Atmospheric Plasma Spray coatings culminated on this work where it was manufactured by Turbula mixing a composite pow-der for J3 at 101 RPM, using known at the time of this study available commercial pow-ders of Titanium and Hydroxyapatite of size range [5-200] and [15-200] μm respectively and density 4,522 and 3,148 g/cm3 respectively. This composite powder is used trough an Atmospheric Plasma Spray system to transform it into a coating hard coating for spe-cific use in stainless steel type 316 implant spinal screws. Based on previous literature and available equipment and materials at CERAMED S.A. facilities, an Atmospheric Plasma Spray program 1 was created. A preliminary study using, pre-selected primary parameters was made to understand the direct influence of Atmospheric Plasma spray system parameters, on coating properties like thickness, pull-out strength, coating crys-tallinity and roughness. The coating showed good results on pull out strength on trough a wide set of ranges showing an improved adhesion strength compared to Hydroxyap-atite, however crystallinity presented results under the required for commercial usage. Using 4 main primary Plasma Spray system factors (Nozzle Distance, Plasma Power, Primary Gas Flow and Secondary Gas Flow), a Design of experiments using 2 best lev-els within the range. By using a full factorial study design of experiences an analysis of variance was performed and the best set of levels for each factor was calculated. Pre-dicted range of results showed to be close to standard requirements but not in compli-ance, between [34,16- 39,66] % of crystallinity. A confirmation experience was per-formed using the best levels for crystallinity with a value of 34,31% and adhesion strength of the coating showed a value of 18,89 ± 3,76 MPa, considerably above the values for single HAp.
publishDate 2019
dc.date.none.fl_str_mv 2019-05-29
2019
2019-05-29T00:00:00Z
2021-04-08T00:30:55Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/73718
url http://hdl.handle.net/10362/73718
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137974015754240