Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.1/73 |
Resumo: | In the past few years, a considerable research effort has been devoted to the development of transformer digital models in order to simulate its behaviour under transient and abnormal operating conditions. Although many three-phase transformer models have been presented in the literature, there is a surprisingly lack of studies regarding the incorporation of winding faults. This paper presents a coupled electromagnetic transformer model for the study of winding inter-turn short-circuits. Particular attention will be given to the model parameters determination, for both healthy and faulty operating conditions. Experimental and simulation test results are presented in the paper, demonstrating the adequacy of the model as well as the methodologies for the parameters determination. |
id |
RCAP_1622ed8c177bfbd369ee571f78673951 |
---|---|
oai_identifier_str |
oai:sapientia.ualg.pt:10400.1/73 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studiesMáquinas eléctricasTransformadoresModelação e simulaçãoAvarias nos enrolamentosDeterminação de parâmetrosIn the past few years, a considerable research effort has been devoted to the development of transformer digital models in order to simulate its behaviour under transient and abnormal operating conditions. Although many three-phase transformer models have been presented in the literature, there is a surprisingly lack of studies regarding the incorporation of winding faults. This paper presents a coupled electromagnetic transformer model for the study of winding inter-turn short-circuits. Particular attention will be given to the model parameters determination, for both healthy and faulty operating conditions. Experimental and simulation test results are presented in the paper, demonstrating the adequacy of the model as well as the methodologies for the parameters determination.VilamouraSapientiaOliveira, L. M. R.Cardoso, A. J. Marques2009-02-13T17:09:24Z20032003-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/pdfhttp://hdl.handle.net/10400.1/73por8º. Congresso Luso Espanhol de Engenharia Eletrotécnica (8 CLEEE). - Vilamoura, 3-5 Julho 2003. - Vol. III. - p. 6.333-6.338AUT: LOL01124;info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-24T10:10:48Zoai:sapientia.ualg.pt:10400.1/73Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:54:30.479700Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
title |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
spellingShingle |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies Oliveira, L. M. R. Máquinas eléctricas Transformadores Modelação e simulação Avarias nos enrolamentos Determinação de parâmetros |
title_short |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
title_full |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
title_fullStr |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
title_full_unstemmed |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
title_sort |
Parameters determination for the coupled electromagnetic transformer model, with particular reference to winding faults studies |
author |
Oliveira, L. M. R. |
author_facet |
Oliveira, L. M. R. Cardoso, A. J. Marques |
author_role |
author |
author2 |
Cardoso, A. J. Marques |
author2_role |
author |
dc.contributor.none.fl_str_mv |
Sapientia |
dc.contributor.author.fl_str_mv |
Oliveira, L. M. R. Cardoso, A. J. Marques |
dc.subject.por.fl_str_mv |
Máquinas eléctricas Transformadores Modelação e simulação Avarias nos enrolamentos Determinação de parâmetros |
topic |
Máquinas eléctricas Transformadores Modelação e simulação Avarias nos enrolamentos Determinação de parâmetros |
description |
In the past few years, a considerable research effort has been devoted to the development of transformer digital models in order to simulate its behaviour under transient and abnormal operating conditions. Although many three-phase transformer models have been presented in the literature, there is a surprisingly lack of studies regarding the incorporation of winding faults. This paper presents a coupled electromagnetic transformer model for the study of winding inter-turn short-circuits. Particular attention will be given to the model parameters determination, for both healthy and faulty operating conditions. Experimental and simulation test results are presented in the paper, demonstrating the adequacy of the model as well as the methodologies for the parameters determination. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003 2003-01-01T00:00:00Z 2009-02-13T17:09:24Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.1/73 |
url |
http://hdl.handle.net/10400.1/73 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
8º. Congresso Luso Espanhol de Engenharia Eletrotécnica (8 CLEEE). - Vilamoura, 3-5 Julho 2003. - Vol. III. - p. 6.333-6.338 AUT: LOL01124; |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Vilamoura |
publisher.none.fl_str_mv |
Vilamoura |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133144211783680 |