Resumo: This paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks, and are valid to other scenarios and environments rather than hospitals.
id RCAP_18c37099b7c54718095bac21d548ecad
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/21043
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Towards the design of efficient nonbeacon-enabled ZigBee networksRemote patient monitoringWireless sensor networkZigBeeIEEE 802.15.4Science & TechnologyThis paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks, and are valid to other scenarios and environments rather than hospitals.Fundação para a Ciência e a Tecnologia (FCT)Grupo AMI – Assistência Médica Integral (Casa de Saúde Guimarães, SA)ElsevierUniversidade do MinhoFernández-López, HelenaAfonso, José A.Correia, J. H.Simões, Ricardo2012-072012-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/21043eng1389-128610.1016/j.comnet.2012.04.013http://www.sciencedirect.com/science/article/pii/S1389128612001533info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:05:23Zoai:repositorium.sdum.uminho.pt:1822/21043Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:55:48.468763Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Towards the design of efficient nonbeacon-enabled ZigBee networks
title Towards the design of efficient nonbeacon-enabled ZigBee networks
spellingShingle Towards the design of efficient nonbeacon-enabled ZigBee networks
Fernández-López, Helena
Remote patient monitoring
Wireless sensor network
ZigBee
IEEE 802.15.4
Science & Technology
title_short Towards the design of efficient nonbeacon-enabled ZigBee networks
title_full Towards the design of efficient nonbeacon-enabled ZigBee networks
title_fullStr Towards the design of efficient nonbeacon-enabled ZigBee networks
title_full_unstemmed Towards the design of efficient nonbeacon-enabled ZigBee networks
title_sort Towards the design of efficient nonbeacon-enabled ZigBee networks
author Fernández-López, Helena
author_facet Fernández-López, Helena
Afonso, José A.
Correia, J. H.
Simões, Ricardo
author_role author
author2 Afonso, José A.
Correia, J. H.
Simões, Ricardo
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Fernández-López, Helena
Afonso, José A.
Correia, J. H.
Simões, Ricardo
dc.subject.por.fl_str_mv Remote patient monitoring
Wireless sensor network
ZigBee
IEEE 802.15.4
Science & Technology
topic Remote patient monitoring
Wireless sensor network
ZigBee
IEEE 802.15.4
Science & Technology
description This paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks, and are valid to other scenarios and environments rather than hospitals.
publishDate 2012
dc.date.none.fl_str_mv 2012-07
2012-07-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/21043
url http://hdl.handle.net/1822/21043
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1389-1286
10.1016/j.comnet.2012.04.013
http://www.sciencedirect.com/science/article/pii/S1389128612001533
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132344546754560