Resumo: To perform mitral valve contour extraction a software application is presented to support the surgeon in the implant size decision. The system is based on the application, to mitral valve surgery images, of active contour models. First, current repair surgery to mitral valve disease is discussed. Active contour models are presented and using different implementation approaches a comparison was done. The algorithms proposed by Kass, Amini, Cohen, Eviatar and Shah (Greedy algorithm) were implemented in test environment. The implementation to be used in the software application, is the one due to Kass with a few modifications related to Cohen’s approach. During surgery, the system needs to be calibrated and the active contour initialised. These processes are supported by a colour segmentation technique, tested with real images, using fuzzy sets. Real open-heart surgery images have been used to test the system developed.
id RCAP_19e6ed9478d835632e454930052caf87
oai_identifier_str oai:repositorio.ipcb.pt:10400.11/2973
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Mitral valve contour extraction using active contour modelsMitral valveActive contourColour segmentationCamera calibrationFuzzy setsTo perform mitral valve contour extraction a software application is presented to support the surgeon in the implant size decision. The system is based on the application, to mitral valve surgery images, of active contour models. First, current repair surgery to mitral valve disease is discussed. Active contour models are presented and using different implementation approaches a comparison was done. The algorithms proposed by Kass, Amini, Cohen, Eviatar and Shah (Greedy algorithm) were implemented in test environment. The implementation to be used in the software application, is the one due to Kass with a few modifications related to Cohen’s approach. During surgery, the system needs to be calibrated and the active contour initialised. These processes are supported by a colour segmentation technique, tested with real images, using fuzzy sets. Real open-heart surgery images have been used to test the system developed.Repositório Científico do Instituto Politécnico de Castelo BrancoGonçalves, P.J.S.Pinto, J.R.C.Ramalho, M.Melo, J. Q.2015-09-18T11:13:11Z1998-031998-03-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.11/2973porGONÇALVES, P.J.S. [et al.] (1998) - Mitral valve contour extraction using active contour models. In Portuguese Conference on Pattern Recognition,10, Lisbon, [S.l. : s.n.]. p. 1-7info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T11:41:11Zoai:repositorio.ipcb.pt:10400.11/2973Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:34:09.271878Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Mitral valve contour extraction using active contour models
title Mitral valve contour extraction using active contour models
spellingShingle Mitral valve contour extraction using active contour models
Gonçalves, P.J.S.
Mitral valve
Active contour
Colour segmentation
Camera calibration
Fuzzy sets
title_short Mitral valve contour extraction using active contour models
title_full Mitral valve contour extraction using active contour models
title_fullStr Mitral valve contour extraction using active contour models
title_full_unstemmed Mitral valve contour extraction using active contour models
title_sort Mitral valve contour extraction using active contour models
author Gonçalves, P.J.S.
author_facet Gonçalves, P.J.S.
Pinto, J.R.C.
Ramalho, M.
Melo, J. Q.
author_role author
author2 Pinto, J.R.C.
Ramalho, M.
Melo, J. Q.
author2_role author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico de Castelo Branco
dc.contributor.author.fl_str_mv Gonçalves, P.J.S.
Pinto, J.R.C.
Ramalho, M.
Melo, J. Q.
dc.subject.por.fl_str_mv Mitral valve
Active contour
Colour segmentation
Camera calibration
Fuzzy sets
topic Mitral valve
Active contour
Colour segmentation
Camera calibration
Fuzzy sets
description To perform mitral valve contour extraction a software application is presented to support the surgeon in the implant size decision. The system is based on the application, to mitral valve surgery images, of active contour models. First, current repair surgery to mitral valve disease is discussed. Active contour models are presented and using different implementation approaches a comparison was done. The algorithms proposed by Kass, Amini, Cohen, Eviatar and Shah (Greedy algorithm) were implemented in test environment. The implementation to be used in the software application, is the one due to Kass with a few modifications related to Cohen’s approach. During surgery, the system needs to be calibrated and the active contour initialised. These processes are supported by a colour segmentation technique, tested with real images, using fuzzy sets. Real open-heart surgery images have been used to test the system developed.
publishDate 1998
dc.date.none.fl_str_mv 1998-03
1998-03-01T00:00:00Z
2015-09-18T11:13:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.11/2973
url http://hdl.handle.net/10400.11/2973
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv GONÇALVES, P.J.S. [et al.] (1998) - Mitral valve contour extraction using active contour models. In Portuguese Conference on Pattern Recognition,10, Lisbon, [S.l. : s.n.]. p. 1-7
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130802959679488