A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency

Detalhes bibliográficos
Autor(a) principal: Silva, Joaquim
Data de Publicação: 2022
Outros Autores: Lopes, Nuno, Curado, Ant?nio, Nunes, Leonel J. L., Lopes, S?rgio I.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/20.500.11960/3063
Resumo: In a very early stage of implementation of a comprehensive experimental campaign for indoor radon assessment, a preevaluation selection of the variables that play a leading role in influencing expected results must be insightfully assessed, by stimulating compatibility between Indoor Air Quality (IAQ) and energy efficiency. Hence, a practical methodology for variable selection based on an analysis of historic data plays a key role concerning radon potential assessment, while never losing sight of the building energy performance. Given the circumstances, this work is focused on the design of a qualitative pre-diagnosis model for the evaluation of radon potential in indoor environments, for different energy efficiency scenarios, by considering a set of relevant variables carefully selected to characterize occupants? risk exposure. A prior survey was done to identify all relevant characteristics that most affect both Indoor Air Quality (IAQ) and building energy efficiency, mainly concerning local geology, thermal insulation, ventilation schemes, energy equipment, renewable energy assets, and occupancy schedules. The selected parameters will be afterward weighted and combined into performance indicators through an evidence-based literature review. In the current early stage, the requirements to drive the software development are presented, together with a software architecture proposal. Finally, it is expected that this pre-diagnosis model will allow a more refined sample selection for indoor radon assessment, by choosing the most susceptible variables that influence radon potential in a given scenario and making it compatible with the building energy efficiency.
id RCAP_1bf9f7ef5d761eb129f1f0fa4dd1b4bb
oai_identifier_str oai:repositorio.ipvc.pt:20.500.11960/3063
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiencyIndoor radon assessmentRadon performance indicatorRadon potentialEnergy efficiencyEnergy performanceEnergy equipmentVentilationIndoor air qualityIn a very early stage of implementation of a comprehensive experimental campaign for indoor radon assessment, a preevaluation selection of the variables that play a leading role in influencing expected results must be insightfully assessed, by stimulating compatibility between Indoor Air Quality (IAQ) and energy efficiency. Hence, a practical methodology for variable selection based on an analysis of historic data plays a key role concerning radon potential assessment, while never losing sight of the building energy performance. Given the circumstances, this work is focused on the design of a qualitative pre-diagnosis model for the evaluation of radon potential in indoor environments, for different energy efficiency scenarios, by considering a set of relevant variables carefully selected to characterize occupants? risk exposure. A prior survey was done to identify all relevant characteristics that most affect both Indoor Air Quality (IAQ) and building energy efficiency, mainly concerning local geology, thermal insulation, ventilation schemes, energy equipment, renewable energy assets, and occupancy schedules. The selected parameters will be afterward weighted and combined into performance indicators through an evidence-based literature review. In the current early stage, the requirements to drive the software development are presented, together with a software architecture proposal. Finally, it is expected that this pre-diagnosis model will allow a more refined sample selection for indoor radon assessment, by choosing the most susceptible variables that influence radon potential in a given scenario and making it compatible with the building energy efficiency.2023-01-03T10:37:12Z2022-06-01T00:00:00Z2022-062022-12-13T08:50:23Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/20.500.11960/3063eng2352-484710.1016/j.egyr.2022.02.100Silva, JoaquimLopes, NunoCurado, Ant?nioNunes, Leonel J. L.Lopes, S?rgio I.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-18T09:41:00Zoai:repositorio.ipvc.pt:20.500.11960/3063Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:43:44.852610Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
title A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
spellingShingle A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
Silva, Joaquim
Indoor radon assessment
Radon performance indicator
Radon potential
Energy efficiency
Energy performance
Energy equipment
Ventilation
Indoor air quality
title_short A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
title_full A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
title_fullStr A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
title_full_unstemmed A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
title_sort A pre-diagnosis model for radon potential evaluation in buildings : a tool for balancing ventilation, indoor air quality and energy efficiency
author Silva, Joaquim
author_facet Silva, Joaquim
Lopes, Nuno
Curado, Ant?nio
Nunes, Leonel J. L.
Lopes, S?rgio I.
author_role author
author2 Lopes, Nuno
Curado, Ant?nio
Nunes, Leonel J. L.
Lopes, S?rgio I.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Silva, Joaquim
Lopes, Nuno
Curado, Ant?nio
Nunes, Leonel J. L.
Lopes, S?rgio I.
dc.subject.por.fl_str_mv Indoor radon assessment
Radon performance indicator
Radon potential
Energy efficiency
Energy performance
Energy equipment
Ventilation
Indoor air quality
topic Indoor radon assessment
Radon performance indicator
Radon potential
Energy efficiency
Energy performance
Energy equipment
Ventilation
Indoor air quality
description In a very early stage of implementation of a comprehensive experimental campaign for indoor radon assessment, a preevaluation selection of the variables that play a leading role in influencing expected results must be insightfully assessed, by stimulating compatibility between Indoor Air Quality (IAQ) and energy efficiency. Hence, a practical methodology for variable selection based on an analysis of historic data plays a key role concerning radon potential assessment, while never losing sight of the building energy performance. Given the circumstances, this work is focused on the design of a qualitative pre-diagnosis model for the evaluation of radon potential in indoor environments, for different energy efficiency scenarios, by considering a set of relevant variables carefully selected to characterize occupants? risk exposure. A prior survey was done to identify all relevant characteristics that most affect both Indoor Air Quality (IAQ) and building energy efficiency, mainly concerning local geology, thermal insulation, ventilation schemes, energy equipment, renewable energy assets, and occupancy schedules. The selected parameters will be afterward weighted and combined into performance indicators through an evidence-based literature review. In the current early stage, the requirements to drive the software development are presented, together with a software architecture proposal. Finally, it is expected that this pre-diagnosis model will allow a more refined sample selection for indoor radon assessment, by choosing the most susceptible variables that influence radon potential in a given scenario and making it compatible with the building energy efficiency.
publishDate 2022
dc.date.none.fl_str_mv 2022-06-01T00:00:00Z
2022-06
2022-12-13T08:50:23Z
2023-01-03T10:37:12Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/20.500.11960/3063
url http://hdl.handle.net/20.500.11960/3063
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2352-4847
10.1016/j.egyr.2022.02.100
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131523494969344