Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/27828 https://doi.org/10.1016/j.jhazmat.2014.07.019 |
Resumo: | Amperometric hydrogen peroxide enzyme inhibition biosensors based on horseradish peroxidase (HRP) immobilised on electropolymerised neutral red (NR) or directly on the surface of carbon film electrodes (CFE) have been successfully applied to the determination of toxic Cr(III) and Cr(VI). Parameters influencing the performance of the biosensor including the enzyme immobilisation method, the amount of hydrogen peroxide, applied potential and electrolyte pH were optimised. The inhibition of horseradish peroxidase by the chromium species was studied under the optimised conditions. Results from the quantitative analysis of chromium ions are discussed in terms of detection limit, linear range and sensitivity. The HRP kinetic interactions reveal mixed binding of Cr(III) with I50 = 3.8 μM and inhibition binding constant Ki = 11.3 μM at HRP/PNR/CFE biosensors and uncompetitive binding of Cr(VI) with I50 = 3.9 μM and Ki = 0.78 μM at HRP/CFE biosensors in the presence of H2O2 substrate. Interferences from other heavy metal ions were studied and the inhibition show very good selectivity towards Cr(III) and Cr(VI). |
id |
RCAP_200ba2df7bdf195f2f3ff672541e94fb |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/27828 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurementsAmperometric biosensorHorseradish peroxidasePoly(neutral red)Cr(III)Cr(VI)Enzyme inhibitionAmperometric hydrogen peroxide enzyme inhibition biosensors based on horseradish peroxidase (HRP) immobilised on electropolymerised neutral red (NR) or directly on the surface of carbon film electrodes (CFE) have been successfully applied to the determination of toxic Cr(III) and Cr(VI). Parameters influencing the performance of the biosensor including the enzyme immobilisation method, the amount of hydrogen peroxide, applied potential and electrolyte pH were optimised. The inhibition of horseradish peroxidase by the chromium species was studied under the optimised conditions. Results from the quantitative analysis of chromium ions are discussed in terms of detection limit, linear range and sensitivity. The HRP kinetic interactions reveal mixed binding of Cr(III) with I50 = 3.8 μM and inhibition binding constant Ki = 11.3 μM at HRP/PNR/CFE biosensors and uncompetitive binding of Cr(VI) with I50 = 3.9 μM and Ki = 0.78 μM at HRP/CFE biosensors in the presence of H2O2 substrate. Interferences from other heavy metal ions were studied and the inhibition show very good selectivity towards Cr(III) and Cr(VI).Elsevier2014-08-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/27828http://hdl.handle.net/10316/27828https://doi.org/10.1016/j.jhazmat.2014.07.019engATTAR, Aisha [et. al] - Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements. "Journal of Hazardous Materials". ISSN 0304-3894. Vol. 279 (2014) p. 348–3550304-3894http://www.sciencedirect.com/science/article/pii/S0304389414005846Attar, AishaGhica, M. EmiliaAmine, AzizBrett, Christopher M. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-02-19T09:18:29Zoai:estudogeral.uc.pt:10316/27828Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:49.621377Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
title |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
spellingShingle |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements Attar, Aisha Amperometric biosensor Horseradish peroxidase Poly(neutral red) Cr(III) Cr(VI) Enzyme inhibition |
title_short |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
title_full |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
title_fullStr |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
title_full_unstemmed |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
title_sort |
Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements |
author |
Attar, Aisha |
author_facet |
Attar, Aisha Ghica, M. Emilia Amine, Aziz Brett, Christopher M. A. |
author_role |
author |
author2 |
Ghica, M. Emilia Amine, Aziz Brett, Christopher M. A. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Attar, Aisha Ghica, M. Emilia Amine, Aziz Brett, Christopher M. A. |
dc.subject.por.fl_str_mv |
Amperometric biosensor Horseradish peroxidase Poly(neutral red) Cr(III) Cr(VI) Enzyme inhibition |
topic |
Amperometric biosensor Horseradish peroxidase Poly(neutral red) Cr(III) Cr(VI) Enzyme inhibition |
description |
Amperometric hydrogen peroxide enzyme inhibition biosensors based on horseradish peroxidase (HRP) immobilised on electropolymerised neutral red (NR) or directly on the surface of carbon film electrodes (CFE) have been successfully applied to the determination of toxic Cr(III) and Cr(VI). Parameters influencing the performance of the biosensor including the enzyme immobilisation method, the amount of hydrogen peroxide, applied potential and electrolyte pH were optimised. The inhibition of horseradish peroxidase by the chromium species was studied under the optimised conditions. Results from the quantitative analysis of chromium ions are discussed in terms of detection limit, linear range and sensitivity. The HRP kinetic interactions reveal mixed binding of Cr(III) with I50 = 3.8 μM and inhibition binding constant Ki = 11.3 μM at HRP/PNR/CFE biosensors and uncompetitive binding of Cr(VI) with I50 = 3.9 μM and Ki = 0.78 μM at HRP/CFE biosensors in the presence of H2O2 substrate. Interferences from other heavy metal ions were studied and the inhibition show very good selectivity towards Cr(III) and Cr(VI). |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08-30 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/27828 http://hdl.handle.net/10316/27828 https://doi.org/10.1016/j.jhazmat.2014.07.019 |
url |
http://hdl.handle.net/10316/27828 https://doi.org/10.1016/j.jhazmat.2014.07.019 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
ATTAR, Aisha [et. al] - Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements. "Journal of Hazardous Materials". ISSN 0304-3894. Vol. 279 (2014) p. 348–355 0304-3894 http://www.sciencedirect.com/science/article/pii/S0304389414005846 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133908816625664 |