Resumo: The results obtained using Trametes versicolor laccase modified graphite electrodes for detection of eleven different commercially reactive dyes are presented for the first time herein. The increase in current upon injection of the analyzed substrate was shown to be approximated by Michaelis–Menten type dependence. The calculated kinetic constants were used to evaluate the applicability of the laccase modified graphite electrode for the detection of reactive dyes in textile effluents.
id RCAP_20bbb3a321d22c120359324bf23b30a2
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/17310
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Biosensors based on laccase for detection of commercially reactive dyesBiosensorCommercially reactive dyeLaccaseScience & TechnologyThe results obtained using Trametes versicolor laccase modified graphite electrodes for detection of eleven different commercially reactive dyes are presented for the first time herein. The increase in current upon injection of the analyzed substrate was shown to be approximated by Michaelis–Menten type dependence. The calculated kinetic constants were used to evaluate the applicability of the laccase modified graphite electrode for the detection of reactive dyes in textile effluents.This paper was submitted as part of a Special Memorial Issue honoring George-Emil Baiulescu. This paper is part of the project CEEX 77/2006 "Computerized filtration and separation systems activated by ultrasounds and controlled by biosensors for textile processes-FILTSOFTUS'' and was supported by "Romanian Authority for Scientific Research/MATNANTECH''.Taylor and FrancisUniversidade do MinhoMunteanu, Florentina-DanielaPaulo, Artur Cavaco20102010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/17310eng0003-271910.1080/00032710903518567info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T11:59:33Zoai:repositorium.sdum.uminho.pt:1822/17310Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:49:20.601278Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Biosensors based on laccase for detection of commercially reactive dyes
title Biosensors based on laccase for detection of commercially reactive dyes
spellingShingle Biosensors based on laccase for detection of commercially reactive dyes
Munteanu, Florentina-Daniela
Biosensor
Commercially reactive dye
Laccase
Science & Technology
title_short Biosensors based on laccase for detection of commercially reactive dyes
title_full Biosensors based on laccase for detection of commercially reactive dyes
title_fullStr Biosensors based on laccase for detection of commercially reactive dyes
title_full_unstemmed Biosensors based on laccase for detection of commercially reactive dyes
title_sort Biosensors based on laccase for detection of commercially reactive dyes
author Munteanu, Florentina-Daniela
author_facet Munteanu, Florentina-Daniela
Paulo, Artur Cavaco
author_role author
author2 Paulo, Artur Cavaco
author2_role author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Munteanu, Florentina-Daniela
Paulo, Artur Cavaco
dc.subject.por.fl_str_mv Biosensor
Commercially reactive dye
Laccase
Science & Technology
topic Biosensor
Commercially reactive dye
Laccase
Science & Technology
description The results obtained using Trametes versicolor laccase modified graphite electrodes for detection of eleven different commercially reactive dyes are presented for the first time herein. The increase in current upon injection of the analyzed substrate was shown to be approximated by Michaelis–Menten type dependence. The calculated kinetic constants were used to evaluate the applicability of the laccase modified graphite electrode for the detection of reactive dyes in textile effluents.
publishDate 2010
dc.date.none.fl_str_mv 2010
2010-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/17310
url http://hdl.handle.net/1822/17310
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0003-2719
10.1080/00032710903518567
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor and Francis
publisher.none.fl_str_mv Taylor and Francis
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132258449227776