Validation of a method to measure light distortion surrounding a source of glare
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/39505 |
Resumo: | Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects. |
id |
RCAP_21d41de5660a5254ce27c79954000143 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/39505 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Validation of a method to measure light distortion surrounding a source of glareLight distortionGlareHaloesPupil sizeValidationScience & TechnologyOur objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects.This study has been funded by the FEDER through the COMPETE Program and by the Portuguese Foundation for Science and Technology in the framework of projects PTDC/ SAU-BEB/098391/2008, PTDC/SAU-BEB/098392/2008, and the Strategic Project PEST-C/FIS/UI607/2011.Society of Photo Optical Instrumentation EngineersUniversidade do MinhoNeves, Helena Isabel FerreiraAraújo, Rute Juliana Ferreira MacedoRico-del-Viejo, L.Silva, Ana CarolinaQueirós, A.González-Méijome, José Manuel20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/39505engFerreira-Neves, Helena; Macedo-de-Araújo, Rute; Rico-del-Viejo, Laura; da-Silva, Ana C.; Queirós, António; González-Méijome, José M.Validation of a method to measure light distortion surrounding a source of glare, Journal of Biomedical Optics, 20, 7, 075002-075002, 2015.1083-366810.1117/1.JBO.20.7.075002info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:36:58Zoai:repositorium.sdum.uminho.pt:1822/39505Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:33:10.900972Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Validation of a method to measure light distortion surrounding a source of glare |
title |
Validation of a method to measure light distortion surrounding a source of glare |
spellingShingle |
Validation of a method to measure light distortion surrounding a source of glare Neves, Helena Isabel Ferreira Light distortion Glare Haloes Pupil size Validation Science & Technology |
title_short |
Validation of a method to measure light distortion surrounding a source of glare |
title_full |
Validation of a method to measure light distortion surrounding a source of glare |
title_fullStr |
Validation of a method to measure light distortion surrounding a source of glare |
title_full_unstemmed |
Validation of a method to measure light distortion surrounding a source of glare |
title_sort |
Validation of a method to measure light distortion surrounding a source of glare |
author |
Neves, Helena Isabel Ferreira |
author_facet |
Neves, Helena Isabel Ferreira Araújo, Rute Juliana Ferreira Macedo Rico-del-Viejo, L. Silva, Ana Carolina Queirós, A. González-Méijome, José Manuel |
author_role |
author |
author2 |
Araújo, Rute Juliana Ferreira Macedo Rico-del-Viejo, L. Silva, Ana Carolina Queirós, A. González-Méijome, José Manuel |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Neves, Helena Isabel Ferreira Araújo, Rute Juliana Ferreira Macedo Rico-del-Viejo, L. Silva, Ana Carolina Queirós, A. González-Méijome, José Manuel |
dc.subject.por.fl_str_mv |
Light distortion Glare Haloes Pupil size Validation Science & Technology |
topic |
Light distortion Glare Haloes Pupil size Validation Science & Technology |
description |
Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 2015-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/39505 |
url |
http://hdl.handle.net/1822/39505 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Ferreira-Neves, Helena; Macedo-de-Araújo, Rute; Rico-del-Viejo, Laura; da-Silva, Ana C.; Queirós, António; González-Méijome, José M.Validation of a method to measure light distortion surrounding a source of glare, Journal of Biomedical Optics, 20, 7, 075002-075002, 2015. 1083-3668 10.1117/1.JBO.20.7.075002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Society of Photo Optical Instrumentation Engineers |
publisher.none.fl_str_mv |
Society of Photo Optical Instrumentation Engineers |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132848877207552 |