Application and comparison of UTCI and PET in temperate climate conditions

Detalhes bibliográficos
Autor(a) principal: Matzarakis, Andreas
Data de Publicação: 2014
Outros Autores: Muthers, Stefan, Rutz, Frank
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.18055/Finis6453
Resumo: The assessment of the thermal bioclimate is based on the human energybalance and derived indices such as Physiologically Equivalent Temperature (PET) or UniversalThermal Climate index (UTCI). These two indices were compared over a period often year based on hourly data in a middle European city with a temperate climate. Theanalysis performed shows that the differences obtained result from the different thermophysiologicalsettings of clothing insulation. For conditions with extremely high vapourpressure values, UTCI yields higher values than PET, which could describe the thermophysiologicalstress more appropriately.
id RCAP_221f5e5ee5a4acd0f2bea1cfd3032554
oai_identifier_str oai:ojs.revistas.rcaap.pt:article/6453
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Application and comparison of UTCI and PET in temperate climate conditionsArtigosThe assessment of the thermal bioclimate is based on the human energybalance and derived indices such as Physiologically Equivalent Temperature (PET) or UniversalThermal Climate index (UTCI). These two indices were compared over a period often year based on hourly data in a middle European city with a temperate climate. Theanalysis performed shows that the differences obtained result from the different thermophysiologicalsettings of clothing insulation. For conditions with extremely high vapourpressure values, UTCI yields higher values than PET, which could describe the thermophysiologicalstress more appropriately.Centro de Estudos Geográficos2014-08-26T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.18055/Finis6453por2182-29050430-5027Matzarakis, AndreasMuthers, StefanRutz, Frankinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-05T14:39:54Zoai:ojs.revistas.rcaap.pt:article/6453Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:12:44.574041Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Application and comparison of UTCI and PET in temperate climate conditions
title Application and comparison of UTCI and PET in temperate climate conditions
spellingShingle Application and comparison of UTCI and PET in temperate climate conditions
Matzarakis, Andreas
Artigos
title_short Application and comparison of UTCI and PET in temperate climate conditions
title_full Application and comparison of UTCI and PET in temperate climate conditions
title_fullStr Application and comparison of UTCI and PET in temperate climate conditions
title_full_unstemmed Application and comparison of UTCI and PET in temperate climate conditions
title_sort Application and comparison of UTCI and PET in temperate climate conditions
author Matzarakis, Andreas
author_facet Matzarakis, Andreas
Muthers, Stefan
Rutz, Frank
author_role author
author2 Muthers, Stefan
Rutz, Frank
author2_role author
author
dc.contributor.author.fl_str_mv Matzarakis, Andreas
Muthers, Stefan
Rutz, Frank
dc.subject.por.fl_str_mv Artigos
topic Artigos
description The assessment of the thermal bioclimate is based on the human energybalance and derived indices such as Physiologically Equivalent Temperature (PET) or UniversalThermal Climate index (UTCI). These two indices were compared over a period often year based on hourly data in a middle European city with a temperate climate. Theanalysis performed shows that the differences obtained result from the different thermophysiologicalsettings of clothing insulation. For conditions with extremely high vapourpressure values, UTCI yields higher values than PET, which could describe the thermophysiologicalstress more appropriately.
publishDate 2014
dc.date.none.fl_str_mv 2014-08-26T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.18055/Finis6453
url https://doi.org/10.18055/Finis6453
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 2182-2905
0430-5027
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Centro de Estudos Geográficos
publisher.none.fl_str_mv Centro de Estudos Geográficos
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799129995252072448