An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal

Detalhes bibliográficos
Autor(a) principal: Salehi, Atefeh
Data de Publicação: 2016
Outros Autores: Torres, Isabel, Ramos, Ana
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/108531
https://doi.org/10.1016/j.egypro.2016.09.109
Resumo: Building airtightness assumes an important role in the energy saving and the indoor thermal comfort. Ventilation rates bring significant impacts on energy usage in the constructions and indoor contaminant concentrations and also setting them as the key parameters in building performance. Ventilation rate have been measured in building for a long time, and there are some developed measurement methodologies related to it in the research domains. However, most of the investigations in recent years have been done usually in the cold climate conditions, while Mediterranean construction are not deeply investigated in the literature. In this paper, the authors present the obtained results of an experimental research which is carried out on the Portuguese residential buildings. The investigation is done by fan pressurization methods, also known as “Blower Door Test (BDT)” as the measurement method as well as Design Builder (DB) as the simulation software. The airtightness measurement of the existing buildings and the influence of air leakage on energy consumption and indoor comfort in different Portuguese construction typologies are focused on the aim of the research. The important parameters of the building such as whole-building air change rates, building infiltration rates, and ventilation effectiveness rate in the residential building are also considered in this research.
id RCAP_2236d56b621a0a711da8ed7f530a714e
oai_identifier_str oai:estudogeral.uc.pt:10316/108531
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, PortugalNatural VentilationIndoor Air QualityEnergyFan pressurizationBlower Door TestBuilding airtightness assumes an important role in the energy saving and the indoor thermal comfort. Ventilation rates bring significant impacts on energy usage in the constructions and indoor contaminant concentrations and also setting them as the key parameters in building performance. Ventilation rate have been measured in building for a long time, and there are some developed measurement methodologies related to it in the research domains. However, most of the investigations in recent years have been done usually in the cold climate conditions, while Mediterranean construction are not deeply investigated in the literature. In this paper, the authors present the obtained results of an experimental research which is carried out on the Portuguese residential buildings. The investigation is done by fan pressurization methods, also known as “Blower Door Test (BDT)” as the measurement method as well as Design Builder (DB) as the simulation software. The airtightness measurement of the existing buildings and the influence of air leakage on energy consumption and indoor comfort in different Portuguese construction typologies are focused on the aim of the research. The important parameters of the building such as whole-building air change rates, building infiltration rates, and ventilation effectiveness rate in the residential building are also considered in this research.Elsevier2016info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/108531http://hdl.handle.net/10316/108531https://doi.org/10.1016/j.egypro.2016.09.109eng18766102Salehi, AtefehTorres, IsabelRamos, Anainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-31T11:07:50Zoai:estudogeral.uc.pt:10316/108531Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:24:50.245460Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
title An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
spellingShingle An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
Salehi, Atefeh
Natural Ventilation
Indoor Air Quality
Energy
Fan pressurization
Blower Door Test
title_short An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
title_full An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
title_fullStr An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
title_full_unstemmed An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
title_sort An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
author Salehi, Atefeh
author_facet Salehi, Atefeh
Torres, Isabel
Ramos, Ana
author_role author
author2 Torres, Isabel
Ramos, Ana
author2_role author
author
dc.contributor.author.fl_str_mv Salehi, Atefeh
Torres, Isabel
Ramos, Ana
dc.subject.por.fl_str_mv Natural Ventilation
Indoor Air Quality
Energy
Fan pressurization
Blower Door Test
topic Natural Ventilation
Indoor Air Quality
Energy
Fan pressurization
Blower Door Test
description Building airtightness assumes an important role in the energy saving and the indoor thermal comfort. Ventilation rates bring significant impacts on energy usage in the constructions and indoor contaminant concentrations and also setting them as the key parameters in building performance. Ventilation rate have been measured in building for a long time, and there are some developed measurement methodologies related to it in the research domains. However, most of the investigations in recent years have been done usually in the cold climate conditions, while Mediterranean construction are not deeply investigated in the literature. In this paper, the authors present the obtained results of an experimental research which is carried out on the Portuguese residential buildings. The investigation is done by fan pressurization methods, also known as “Blower Door Test (BDT)” as the measurement method as well as Design Builder (DB) as the simulation software. The airtightness measurement of the existing buildings and the influence of air leakage on energy consumption and indoor comfort in different Portuguese construction typologies are focused on the aim of the research. The important parameters of the building such as whole-building air change rates, building infiltration rates, and ventilation effectiveness rate in the residential building are also considered in this research.
publishDate 2016
dc.date.none.fl_str_mv 2016
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/108531
http://hdl.handle.net/10316/108531
https://doi.org/10.1016/j.egypro.2016.09.109
url http://hdl.handle.net/10316/108531
https://doi.org/10.1016/j.egypro.2016.09.109
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 18766102
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134132006027264