Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
Autor(a) principal: | |
---|---|
Data de Publicação: | 1997 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/1585 |
Resumo: | A device for mixing air with a pollutant (e.g., volatile organic compounds) is presented, which is based on principles of evaporation and diffusion. A wide-necked flask containing an aluminium cylindrical body, allows the evaporating area to be preset to 5.75 cm² or 23.03 cm². The distance from the evaporating surface to the region of passage of the air is adjustable between 0 and 8 cm, which allows to assay a wide range of evaporation flows (for toluene: 1.5 to 200 mg/minute). |
id |
RCAP_22b559d3479e8770220c7aafa92f402e |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/1585 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory researchScience & TechnologyA device for mixing air with a pollutant (e.g., volatile organic compounds) is presented, which is based on principles of evaporation and diffusion. A wide-necked flask containing an aluminium cylindrical body, allows the evaporating area to be preset to 5.75 cm² or 23.03 cm². The distance from the evaporating surface to the region of passage of the air is adjustable between 0 and 8 cm, which allows to assay a wide range of evaporation flows (for toluene: 1.5 to 200 mg/minute).Chapman & HallUniversidade do MinhoPeixoto, J.Mota, M.1997-011997-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/1585eng"Biotechnology techniques". ISSN 0951-208X. 11:1 (1997) 1-6.0951-208X10.1007/BF02764440info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:51:51Zoai:repositorium.sdum.uminho.pt:1822/1585Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:50:51.552924Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
title |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
spellingShingle |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research Peixoto, J. Science & Technology |
title_short |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
title_full |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
title_fullStr |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
title_full_unstemmed |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
title_sort |
Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research |
author |
Peixoto, J. |
author_facet |
Peixoto, J. Mota, M. |
author_role |
author |
author2 |
Mota, M. |
author2_role |
author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Peixoto, J. Mota, M. |
dc.subject.por.fl_str_mv |
Science & Technology |
topic |
Science & Technology |
description |
A device for mixing air with a pollutant (e.g., volatile organic compounds) is presented, which is based on principles of evaporation and diffusion. A wide-necked flask containing an aluminium cylindrical body, allows the evaporating area to be preset to 5.75 cm² or 23.03 cm². The distance from the evaporating surface to the region of passage of the air is adjustable between 0 and 8 cm, which allows to assay a wide range of evaporation flows (for toluene: 1.5 to 200 mg/minute). |
publishDate |
1997 |
dc.date.none.fl_str_mv |
1997-01 1997-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/1585 |
url |
http://hdl.handle.net/1822/1585 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
"Biotechnology techniques". ISSN 0951-208X. 11:1 (1997) 1-6. 0951-208X 10.1007/BF02764440 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Chapman & Hall |
publisher.none.fl_str_mv |
Chapman & Hall |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133094203097088 |