Resumo: A device for mixing air with a pollutant (e.g., volatile organic compounds) is presented, which is based on principles of evaporation and diffusion. A wide-necked flask containing an aluminium cylindrical body, allows the evaporating area to be preset to 5.75 cm² or 23.03 cm². The distance from the evaporating surface to the region of passage of the air is adjustable between 0 and 8 cm, which allows to assay a wide range of evaporation flows (for toluene: 1.5 to 200 mg/minute).
id RCAP_22b559d3479e8770220c7aafa92f402e
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/1585
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory researchScience & TechnologyA device for mixing air with a pollutant (e.g., volatile organic compounds) is presented, which is based on principles of evaporation and diffusion. A wide-necked flask containing an aluminium cylindrical body, allows the evaporating area to be preset to 5.75 cm² or 23.03 cm². The distance from the evaporating surface to the region of passage of the air is adjustable between 0 and 8 cm, which allows to assay a wide range of evaporation flows (for toluene: 1.5 to 200 mg/minute).Chapman & HallUniversidade do MinhoPeixoto, J.Mota, M.1997-011997-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/1585eng"Biotechnology techniques". ISSN 0951-208X. 11:1 (1997) 1-6.0951-208X10.1007/BF02764440info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:51:51Zoai:repositorium.sdum.uminho.pt:1822/1585Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:50:51.552924Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
title Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
spellingShingle Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
Peixoto, J.
Science & Technology
title_short Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
title_full Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
title_fullStr Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
title_full_unstemmed Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
title_sort Volatile organic compounds evaporation chamber for the simulation of gas effluents in laboratory research
author Peixoto, J.
author_facet Peixoto, J.
Mota, M.
author_role author
author2 Mota, M.
author2_role author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Peixoto, J.
Mota, M.
dc.subject.por.fl_str_mv Science & Technology
topic Science & Technology
description A device for mixing air with a pollutant (e.g., volatile organic compounds) is presented, which is based on principles of evaporation and diffusion. A wide-necked flask containing an aluminium cylindrical body, allows the evaporating area to be preset to 5.75 cm² or 23.03 cm². The distance from the evaporating surface to the region of passage of the air is adjustable between 0 and 8 cm, which allows to assay a wide range of evaporation flows (for toluene: 1.5 to 200 mg/minute).
publishDate 1997
dc.date.none.fl_str_mv 1997-01
1997-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/1585
url http://hdl.handle.net/1822/1585
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv "Biotechnology techniques". ISSN 0951-208X. 11:1 (1997) 1-6.
0951-208X
10.1007/BF02764440
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Chapman & Hall
publisher.none.fl_str_mv Chapman & Hall
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133094203097088