Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes

Detalhes bibliográficos
Autor(a) principal: João Dias Oliveira
Data de Publicação: 2016
Outros Autores: H. Rodrigues, Humberto Varum
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/10216/108679
Resumo: Purpose - When a numerous amount of buildings was built in reinforced concrete, in a period whenthe regulations did not have the design philosophy for the occurrence of earthquakes, it is of extremeimportance to carry out full and effective structural assessments, specially considering and comparingbare frame and infilled structure. The paper aims to discuss these issues.Design/methodology/approach - Among several possibilities to make the evaluation as, simplified,linear analysis and static non-linear analysis, the non-linear dynamic can provide the most accuratenumerical behaviour compared to the real one. The time-history non-linear analyses are developed onthe software SeismoStruct for different levels of intensity. Local verifications are then appliedseparately from both Eurocode and Italian Code.Findings - The application of validated models for the analysis of real buildings allows a completeseismic assessment. The level of uncertainty increases integrating particularities regarding the infillmasonry walls. The paper shows important global and local seismic safety for these complex typologyof buildings.Originality/value - A representative common concrete structure without seismic provisions is firstanalysed and discussed in terms of global behaviour, deformations and progression of forces. The casestudy structure is considered both as bare structure and with integrated infill panels. It is alsodiscussed in a local level, about brittle and ductile mechanisms, and extra comparisons betweendifferent interpretations of different standards. The case study structure is considered both as barestructure and with integrated infill panels.Keywords 3D modelling, Dynamic and non-linear analysis, Infill masonry, RC building,Seismic assessmentPaper type Case study
id RCAP_24412f2dfc21f15b5605bfd37d1d3aaa
oai_identifier_str oai:repositorio-aberto.up.pt:10216/108679
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codesEngenharia estrutural, Engenharia civilStructural engineering, Civil engineeringPurpose - When a numerous amount of buildings was built in reinforced concrete, in a period whenthe regulations did not have the design philosophy for the occurrence of earthquakes, it is of extremeimportance to carry out full and effective structural assessments, specially considering and comparingbare frame and infilled structure. The paper aims to discuss these issues.Design/methodology/approach - Among several possibilities to make the evaluation as, simplified,linear analysis and static non-linear analysis, the non-linear dynamic can provide the most accuratenumerical behaviour compared to the real one. The time-history non-linear analyses are developed onthe software SeismoStruct for different levels of intensity. Local verifications are then appliedseparately from both Eurocode and Italian Code.Findings - The application of validated models for the analysis of real buildings allows a completeseismic assessment. The level of uncertainty increases integrating particularities regarding the infillmasonry walls. The paper shows important global and local seismic safety for these complex typologyof buildings.Originality/value - A representative common concrete structure without seismic provisions is firstanalysed and discussed in terms of global behaviour, deformations and progression of forces. The casestudy structure is considered both as bare structure and with integrated infill panels. It is alsodiscussed in a local level, about brittle and ductile mechanisms, and extra comparisons betweendifferent interpretations of different standards. The case study structure is considered both as barestructure and with integrated infill panels.Keywords 3D modelling, Dynamic and non-linear analysis, Infill masonry, RC building,Seismic assessmentPaper type Case study2016-12-302016-12-30T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/10216/108679eng0264-440110.1108/EC-06-2014-0141João Dias OliveiraH. RodriguesHumberto Varuminfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T16:01:50Zoai:repositorio-aberto.up.pt:10216/108679Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:36:53.437267Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
title Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
spellingShingle Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
João Dias Oliveira
Engenharia estrutural, Engenharia civil
Structural engineering, Civil engineering
title_short Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
title_full Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
title_fullStr Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
title_full_unstemmed Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
title_sort Seismic assessment of low ductile RC structures: Buildings from before the modern seismic codes
author João Dias Oliveira
author_facet João Dias Oliveira
H. Rodrigues
Humberto Varum
author_role author
author2 H. Rodrigues
Humberto Varum
author2_role author
author
dc.contributor.author.fl_str_mv João Dias Oliveira
H. Rodrigues
Humberto Varum
dc.subject.por.fl_str_mv Engenharia estrutural, Engenharia civil
Structural engineering, Civil engineering
topic Engenharia estrutural, Engenharia civil
Structural engineering, Civil engineering
description Purpose - When a numerous amount of buildings was built in reinforced concrete, in a period whenthe regulations did not have the design philosophy for the occurrence of earthquakes, it is of extremeimportance to carry out full and effective structural assessments, specially considering and comparingbare frame and infilled structure. The paper aims to discuss these issues.Design/methodology/approach - Among several possibilities to make the evaluation as, simplified,linear analysis and static non-linear analysis, the non-linear dynamic can provide the most accuratenumerical behaviour compared to the real one. The time-history non-linear analyses are developed onthe software SeismoStruct for different levels of intensity. Local verifications are then appliedseparately from both Eurocode and Italian Code.Findings - The application of validated models for the analysis of real buildings allows a completeseismic assessment. The level of uncertainty increases integrating particularities regarding the infillmasonry walls. The paper shows important global and local seismic safety for these complex typologyof buildings.Originality/value - A representative common concrete structure without seismic provisions is firstanalysed and discussed in terms of global behaviour, deformations and progression of forces. The casestudy structure is considered both as bare structure and with integrated infill panels. It is alsodiscussed in a local level, about brittle and ductile mechanisms, and extra comparisons betweendifferent interpretations of different standards. The case study structure is considered both as barestructure and with integrated infill panels.Keywords 3D modelling, Dynamic and non-linear analysis, Infill masonry, RC building,Seismic assessmentPaper type Case study
publishDate 2016
dc.date.none.fl_str_mv 2016-12-30
2016-12-30T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/108679
url https://hdl.handle.net/10216/108679
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0264-4401
10.1108/EC-06-2014-0141
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136277022375937