Resumo: | This paper reports the results of experimental tests performed according to ISO 23953 in vertical open and closed multideck display cases to evaluate the influence of double glass doors in the direct energy consumption, product simulator temperature, evaporator total condensed water mass, total heat load and total energy consumption. Tests were performed at climate classes n.º 3 (Ta = 25°C; a = 60%) and n.º 6 (Ta = 27°C; a = 70%). The direct energy consumption is 46% higher at the closed display case due to the heat load generated by the heated glass doors frame and defrost heaters. The product simulator temperature is higher and more stable at the open display case. The highest product simulator temperature is lower (-1.4°C) at the closed display case and less stable (+2.7°C variation) due to the opening doors period. The total mass of condensed water at the evaporator is reduced 87% and the total energy consumption is 58% lower at the closed display case. In conclusion, the estimated total energy consumption (compressor and components) is reduced at the glass doors display case. Thus, it is verified that the use of refrigeration equipment closed to ambient air is increasingly seen as the definitive solution, given the current concerns with energy consumption and sustainability of the heat exchange processes. |
id |
RCAP_24afd7b6a891a82ae1e68c207098b464 |
---|---|
oai_identifier_str |
oai:ubibliorum.ubi.pt:10400.6/7411 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditionsDisplay caseGlass doorsEnvironmental conditionsEnergy consumptionThis paper reports the results of experimental tests performed according to ISO 23953 in vertical open and closed multideck display cases to evaluate the influence of double glass doors in the direct energy consumption, product simulator temperature, evaporator total condensed water mass, total heat load and total energy consumption. Tests were performed at climate classes n.º 3 (Ta = 25°C; a = 60%) and n.º 6 (Ta = 27°C; a = 70%). The direct energy consumption is 46% higher at the closed display case due to the heat load generated by the heated glass doors frame and defrost heaters. The product simulator temperature is higher and more stable at the open display case. The highest product simulator temperature is lower (-1.4°C) at the closed display case and less stable (+2.7°C variation) due to the opening doors period. The total mass of condensed water at the evaporator is reduced 87% and the total energy consumption is 58% lower at the closed display case. In conclusion, the estimated total energy consumption (compressor and components) is reduced at the glass doors display case. Thus, it is verified that the use of refrigeration equipment closed to ambient air is increasingly seen as the definitive solution, given the current concerns with energy consumption and sustainability of the heat exchange processes.+AGRO 2018 - International Congress on Organizational ManagementuBibliorumHeidinger, Gustavo GaldiNascimento, Samuel Mariano doGaspar, Pedro DinisSilva, Pedro Dinho da2019-10-25T16:16:43Z20182018-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/7411enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-15T09:46:46Zoai:ubibliorum.ubi.pt:10400.6/7411Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:47:56.168907Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
title |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
spellingShingle |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions Heidinger, Gustavo Galdi Display case Glass doors Environmental conditions Energy consumption |
title_short |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
title_full |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
title_fullStr |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
title_full_unstemmed |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
title_sort |
Experimental comparison at open and closed vertical multidecks display cases at standard and tropical environmental conditions |
author |
Heidinger, Gustavo Galdi |
author_facet |
Heidinger, Gustavo Galdi Nascimento, Samuel Mariano do Gaspar, Pedro Dinis Silva, Pedro Dinho da |
author_role |
author |
author2 |
Nascimento, Samuel Mariano do Gaspar, Pedro Dinis Silva, Pedro Dinho da |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
uBibliorum |
dc.contributor.author.fl_str_mv |
Heidinger, Gustavo Galdi Nascimento, Samuel Mariano do Gaspar, Pedro Dinis Silva, Pedro Dinho da |
dc.subject.por.fl_str_mv |
Display case Glass doors Environmental conditions Energy consumption |
topic |
Display case Glass doors Environmental conditions Energy consumption |
description |
This paper reports the results of experimental tests performed according to ISO 23953 in vertical open and closed multideck display cases to evaluate the influence of double glass doors in the direct energy consumption, product simulator temperature, evaporator total condensed water mass, total heat load and total energy consumption. Tests were performed at climate classes n.º 3 (Ta = 25°C; a = 60%) and n.º 6 (Ta = 27°C; a = 70%). The direct energy consumption is 46% higher at the closed display case due to the heat load generated by the heated glass doors frame and defrost heaters. The product simulator temperature is higher and more stable at the open display case. The highest product simulator temperature is lower (-1.4°C) at the closed display case and less stable (+2.7°C variation) due to the opening doors period. The total mass of condensed water at the evaporator is reduced 87% and the total energy consumption is 58% lower at the closed display case. In conclusion, the estimated total energy consumption (compressor and components) is reduced at the glass doors display case. Thus, it is verified that the use of refrigeration equipment closed to ambient air is increasingly seen as the definitive solution, given the current concerns with energy consumption and sustainability of the heat exchange processes. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018 2018-01-01T00:00:00Z 2019-10-25T16:16:43Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.6/7411 |
url |
http://hdl.handle.net/10400.6/7411 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
+AGRO 2018 - International Congress on Organizational Management |
publisher.none.fl_str_mv |
+AGRO 2018 - International Congress on Organizational Management |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136374172942336 |