Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.8/3546 |
Resumo: | Continuous and reliable blood pressure (BP) monitoring during standard clinical manoeuvres provides important information about the cardiovascular system condition. Common invasive methods are accurate but denote increased risk. An alternative approach is based on changes in pulse transit time (PTT) defined as the time delay between the R-wave of the electrocardiogram (ECG) and the peak value of the photoplethysmogram (PPG) signal at the same cardiac cycle. |
id |
RCAP_25596784e0799f94bdc4c5b1d3923c15 |
---|---|
oai_identifier_str |
oai:iconline.ipleiria.pt:10400.8/3546 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approachBlood pressurePulse Transit TimeClinical autonomic manoeuvresContinuous and reliable blood pressure (BP) monitoring during standard clinical manoeuvres provides important information about the cardiovascular system condition. Common invasive methods are accurate but denote increased risk. An alternative approach is based on changes in pulse transit time (PTT) defined as the time delay between the R-wave of the electrocardiogram (ECG) and the peak value of the photoplethysmogram (PPG) signal at the same cardiac cycle.BMC Health Services ResearchIC-OnlineDuarte, DianaLopes, Nuno VieiraFonseca-Pinto, Rui2018-09-24T07:59:19Z2016-07-062016-07-06T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.8/3546eng10.1186/s12913-016-1423-5info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-17T15:47:24Zoai:iconline.ipleiria.pt:10400.8/3546Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:47:37.298Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
title |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
spellingShingle |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach Duarte, Diana Blood pressure Pulse Transit Time Clinical autonomic manoeuvres |
title_short |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
title_full |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
title_fullStr |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
title_full_unstemmed |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
title_sort |
Blood pressure assessment during standard clinical manoeuvres: A noninvasive PPT based approach |
author |
Duarte, Diana |
author_facet |
Duarte, Diana Lopes, Nuno Vieira Fonseca-Pinto, Rui |
author_role |
author |
author2 |
Lopes, Nuno Vieira Fonseca-Pinto, Rui |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
IC-Online |
dc.contributor.author.fl_str_mv |
Duarte, Diana Lopes, Nuno Vieira Fonseca-Pinto, Rui |
dc.subject.por.fl_str_mv |
Blood pressure Pulse Transit Time Clinical autonomic manoeuvres |
topic |
Blood pressure Pulse Transit Time Clinical autonomic manoeuvres |
description |
Continuous and reliable blood pressure (BP) monitoring during standard clinical manoeuvres provides important information about the cardiovascular system condition. Common invasive methods are accurate but denote increased risk. An alternative approach is based on changes in pulse transit time (PTT) defined as the time delay between the R-wave of the electrocardiogram (ECG) and the peak value of the photoplethysmogram (PPG) signal at the same cardiac cycle. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-07-06 2016-07-06T00:00:00Z 2018-09-24T07:59:19Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.8/3546 |
url |
http://hdl.handle.net/10400.8/3546 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1186/s12913-016-1423-5 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
BMC Health Services Research |
publisher.none.fl_str_mv |
BMC Health Services Research |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136970183540736 |