Resumo: A two-step model able to predict the non-linear response of FRP strengthened threedimensional masonry structures is presented. In the first step, non-strengthened masonry is substituted by a macroscopically equivalent homogeneous material through a kinematic model based on finite elements and working on a heterogeneous assemblage of blocks. Non-linearity is concentrated exclusively on joints reduced to interfaces, exhibiting a frictional behaviour with limited tensile and compressive strength with softening. The homogenized stress-strain behaviour evaluated at the meso-scale is then implemented at a structural level in a finite element non-linear code, relying on an assemblage of rigid infinitely resistant six-noded wedge elements and non-linear interfaces, with deterioration of the mechanical properties. FRP reinforcing strips are modelled through rigid triangles and non-linear interfaces between adjoining triangles. Delamination from the support is accounted for, by modelling FRP-masonry bond by means of non-linear softening triangular interfaces. Italian code CNR DT 200 0 formulas are used to evaluate peak interface tangential strength and post peak behaviour. A structural examples relying into a masonry deep beam is presented for validation purposes.
id RCAP_270a208f6168d256d9ba273b70d736f0
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/21474
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling A simple homogenized model for the non-linear analysis of FRP strengthened masonry structuresMasonryFibre-reinforced polymerNon-linear modelHomogenizationFinite element methodA two-step model able to predict the non-linear response of FRP strengthened threedimensional masonry structures is presented. In the first step, non-strengthened masonry is substituted by a macroscopically equivalent homogeneous material through a kinematic model based on finite elements and working on a heterogeneous assemblage of blocks. Non-linearity is concentrated exclusively on joints reduced to interfaces, exhibiting a frictional behaviour with limited tensile and compressive strength with softening. The homogenized stress-strain behaviour evaluated at the meso-scale is then implemented at a structural level in a finite element non-linear code, relying on an assemblage of rigid infinitely resistant six-noded wedge elements and non-linear interfaces, with deterioration of the mechanical properties. FRP reinforcing strips are modelled through rigid triangles and non-linear interfaces between adjoining triangles. Delamination from the support is accounted for, by modelling FRP-masonry bond by means of non-linear softening triangular interfaces. Italian code CNR DT 200 0 formulas are used to evaluate peak interface tangential strength and post peak behaviour. A structural examples relying into a masonry deep beam is presented for validation purposes.(undefined)Civil-Comp PressUniversidade do MinhoMilani, G.Lourenço, Paulo B.20122012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/21474eng97819050885461759-3433info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:08:43Zoai:repositorium.sdum.uminho.pt:1822/21474Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:59:58.377262Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
title A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
spellingShingle A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
Milani, G.
Masonry
Fibre-reinforced polymer
Non-linear model
Homogenization
Finite element method
title_short A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
title_full A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
title_fullStr A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
title_full_unstemmed A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
title_sort A simple homogenized model for the non-linear analysis of FRP strengthened masonry structures
author Milani, G.
author_facet Milani, G.
Lourenço, Paulo B.
author_role author
author2 Lourenço, Paulo B.
author2_role author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Milani, G.
Lourenço, Paulo B.
dc.subject.por.fl_str_mv Masonry
Fibre-reinforced polymer
Non-linear model
Homogenization
Finite element method
topic Masonry
Fibre-reinforced polymer
Non-linear model
Homogenization
Finite element method
description A two-step model able to predict the non-linear response of FRP strengthened threedimensional masonry structures is presented. In the first step, non-strengthened masonry is substituted by a macroscopically equivalent homogeneous material through a kinematic model based on finite elements and working on a heterogeneous assemblage of blocks. Non-linearity is concentrated exclusively on joints reduced to interfaces, exhibiting a frictional behaviour with limited tensile and compressive strength with softening. The homogenized stress-strain behaviour evaluated at the meso-scale is then implemented at a structural level in a finite element non-linear code, relying on an assemblage of rigid infinitely resistant six-noded wedge elements and non-linear interfaces, with deterioration of the mechanical properties. FRP reinforcing strips are modelled through rigid triangles and non-linear interfaces between adjoining triangles. Delamination from the support is accounted for, by modelling FRP-masonry bond by means of non-linear softening triangular interfaces. Italian code CNR DT 200 0 formulas are used to evaluate peak interface tangential strength and post peak behaviour. A structural examples relying into a masonry deep beam is presented for validation purposes.
publishDate 2012
dc.date.none.fl_str_mv 2012
2012-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/21474
url http://hdl.handle.net/1822/21474
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 9781905088546
1759-3433
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Civil-Comp Press
publisher.none.fl_str_mv Civil-Comp Press
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132393146155008