Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.

Detalhes bibliográficos
Autor(a) principal: Kronenberg, P
Data de Publicação: 2015
Outros Autores: Traxer, O
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.10/2295
Resumo: PURPOSE: We assessed whether stripping and cleaving the laser fiber tip with specialized tools, namely laser fiber strippers, or ceramic or metal scissors, would influence lithotripsy performance. MATERIALS AND METHODS: Laser fiber tips were stripped with a specialized laser fiber stripper or remained coated. The tips were then cleaved with metal or ceramic scissors. Laser lithotripsy experiments were performed with the 4 fiber tip combinations using an automated laser fragmentation testing system with artificial stones made of plaster of Paris or BegoStone Plus (Bego, Lincoln, Rhode Island). High frequency-low pulse energy (20 Hz and 0.5 J) and low frequency-high pulse energy (5 Hz and 2.0 J) settings were used for 30 seconds. Fissure width, depth and volume, and laser fiber tip photos were analyzed. RESULTS: Coated laser fiber tips always achieved significantly higher ablation volumes (sometimes greater than 50%) than stripped laser fiber tips (p <0.00001) regardless of cleaving scissor type, stone material or lithotripter setting. Coated fiber tips cleaved with metal scissors ablated as well as those cleaved with ceramic scissors (p = 0.16). However, stripped fibers were much less ablative when they were cut with metal scissors compared to ceramic scissors (p <0.00001). Harder stone material decreased ablation volume (p <0.00001). Low frequency-high pulse energy settings were an average of 3 times more ablative than high frequency-low pulse energy settings (p <0.00001). Stripping the fibers, a harder stone material and low frequency-high pulse energy settings were associated with increased fiber tip degradation. CONCLUSIONS: Coated laser fibers provided better lithotripsy performance and metal scissors were as good as ceramic scissors to cleave coated fibers. This knowledge may improve and simplify the way that laser lithotripsy procedures are done worldwide.
id RCAP_28583d39a19acea2c2cfae3b3a4ff4c7
oai_identifier_str oai:repositorio.hff.min-saude.pt:10400.10/2295
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.Laser lithotripsyPURPOSE: We assessed whether stripping and cleaving the laser fiber tip with specialized tools, namely laser fiber strippers, or ceramic or metal scissors, would influence lithotripsy performance. MATERIALS AND METHODS: Laser fiber tips were stripped with a specialized laser fiber stripper or remained coated. The tips were then cleaved with metal or ceramic scissors. Laser lithotripsy experiments were performed with the 4 fiber tip combinations using an automated laser fragmentation testing system with artificial stones made of plaster of Paris or BegoStone Plus (Bego, Lincoln, Rhode Island). High frequency-low pulse energy (20 Hz and 0.5 J) and low frequency-high pulse energy (5 Hz and 2.0 J) settings were used for 30 seconds. Fissure width, depth and volume, and laser fiber tip photos were analyzed. RESULTS: Coated laser fiber tips always achieved significantly higher ablation volumes (sometimes greater than 50%) than stripped laser fiber tips (p <0.00001) regardless of cleaving scissor type, stone material or lithotripter setting. Coated fiber tips cleaved with metal scissors ablated as well as those cleaved with ceramic scissors (p = 0.16). However, stripped fibers were much less ablative when they were cut with metal scissors compared to ceramic scissors (p <0.00001). Harder stone material decreased ablation volume (p <0.00001). Low frequency-high pulse energy settings were an average of 3 times more ablative than high frequency-low pulse energy settings (p <0.00001). Stripping the fibers, a harder stone material and low frequency-high pulse energy settings were associated with increased fiber tip degradation. CONCLUSIONS: Coated laser fibers provided better lithotripsy performance and metal scissors were as good as ceramic scissors to cleave coated fibers. This knowledge may improve and simplify the way that laser lithotripsy procedures are done worldwide.Lippincott Williams & WilkinsRepositório do Hospital Prof. Doutor Fernando FonsecaKronenberg, PTraxer, O2019-06-19T14:51:53Z2015-01-01T00:00:00Z2015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.10/2295engJ Urol. 2015 Mar;193(3):1030-5.1527-379210.1016/j.juro.2014.07.110.metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-20T15:52:59Zoai:repositorio.hff.min-saude.pt:10400.10/2295Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:53:14.952171Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
title Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
spellingShingle Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
Kronenberg, P
Laser lithotripsy
title_short Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
title_full Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
title_fullStr Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
title_full_unstemmed Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
title_sort Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.
author Kronenberg, P
author_facet Kronenberg, P
Traxer, O
author_role author
author2 Traxer, O
author2_role author
dc.contributor.none.fl_str_mv Repositório do Hospital Prof. Doutor Fernando Fonseca
dc.contributor.author.fl_str_mv Kronenberg, P
Traxer, O
dc.subject.por.fl_str_mv Laser lithotripsy
topic Laser lithotripsy
description PURPOSE: We assessed whether stripping and cleaving the laser fiber tip with specialized tools, namely laser fiber strippers, or ceramic or metal scissors, would influence lithotripsy performance. MATERIALS AND METHODS: Laser fiber tips were stripped with a specialized laser fiber stripper or remained coated. The tips were then cleaved with metal or ceramic scissors. Laser lithotripsy experiments were performed with the 4 fiber tip combinations using an automated laser fragmentation testing system with artificial stones made of plaster of Paris or BegoStone Plus (Bego, Lincoln, Rhode Island). High frequency-low pulse energy (20 Hz and 0.5 J) and low frequency-high pulse energy (5 Hz and 2.0 J) settings were used for 30 seconds. Fissure width, depth and volume, and laser fiber tip photos were analyzed. RESULTS: Coated laser fiber tips always achieved significantly higher ablation volumes (sometimes greater than 50%) than stripped laser fiber tips (p <0.00001) regardless of cleaving scissor type, stone material or lithotripter setting. Coated fiber tips cleaved with metal scissors ablated as well as those cleaved with ceramic scissors (p = 0.16). However, stripped fibers were much less ablative when they were cut with metal scissors compared to ceramic scissors (p <0.00001). Harder stone material decreased ablation volume (p <0.00001). Low frequency-high pulse energy settings were an average of 3 times more ablative than high frequency-low pulse energy settings (p <0.00001). Stripping the fibers, a harder stone material and low frequency-high pulse energy settings were associated with increased fiber tip degradation. CONCLUSIONS: Coated laser fibers provided better lithotripsy performance and metal scissors were as good as ceramic scissors to cleave coated fibers. This knowledge may improve and simplify the way that laser lithotripsy procedures are done worldwide.
publishDate 2015
dc.date.none.fl_str_mv 2015-01-01T00:00:00Z
2015-01-01T00:00:00Z
2019-06-19T14:51:53Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.10/2295
url http://hdl.handle.net/10400.10/2295
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv J Urol. 2015 Mar;193(3):1030-5.
1527-3792
10.1016/j.juro.2014.07.110.
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Lippincott Williams & Wilkins
publisher.none.fl_str_mv Lippincott Williams & Wilkins
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130399657426944