Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.17/4119 |
Resumo: | Objective: Aortic neck dilatation (AND) occurs after endovascular aneurysm repair (EVAR) with self expanding stent grafts (SESs). Whether it continues, ultimately exceeding the endograft diameter leading to abdominal aortic aneurysm (AAA) rupture, remains uncertain. Dynamics, risk factors, and clinical relevance of AND were investigated after EVAR with standard SESs. Methods: All intact EVAR patients treated from 2000 to 2015 at a tertiary institution were included. Demographic, anatomical, and device related characteristics were investigated as risk factors for AND. Outer to outer diameters were measured at a single standardised aortic level on reconstructed computed tomography (CT) images. Results: A total of 460 patients were included (median follow up 5.2 years, interquartile range [IQR] 3.0, 7.7 years; CT imaging follow up 3.3 years, IQR 1.3, 5.4). Baseline neck diameter was 24 mm (IQR 22, 26) and increased 11.1% (IQR 1.5%, 21.9%) at last CT imaging. Endograft oversizing was 20.0% (IQR 13.6, 28.0). AND was greater during the first year (5.2% [IQR 0, 11.7]) decreasing subsequently (two to four years to 1.4%/year [IQR 0.0, 4.5%], p ≤ .001) and was associated with suprarenal fixation endografts (t value = 7.9, p < .001) and oversizing (t value = 4.4, p < .001). AND exceeding the endograft was 3.5% (95% CI 2.2% - 4.8%) and 14.4% (95% CI 11.0% - 17.8%) at five and eight years, respectively. Excessive AND was associated with baseline neck diameter (OR 1.2/mm, 95% CI 1.05 - 1.41) while the Excluder endograft had a protective effect (OR 0.15, 95% CI 0.04 - 0.58). Excessive AND was associated with type 1A endoleak (HR 3.3, 95% CI 1.1 - 9.7) and endograft migration > 5 mm (HR 3.1, 95% CI 1.4 - 6.9). Conclusion: AND after EVAR with SES is associated with endograft oversizing and radial force but decelerates after the first post-operative year. Baseline aortic neck diameter and suprarenal stent bearing endografts were associated with an increased risk of AND beyond nominal stent graft diameter. However, it remains unclear whether patient selection, differences in endograft radial force or the suprarenal stent are accountable for this difference. |
id |
RCAP_297b655bb4a50d2b5d969de0d14b2f37 |
---|---|
oai_identifier_str |
oai:repositorio.chlc.min-saude.pt:10400.17/4119 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm RepairHSM CIR VASCAgedFemaleMaleHumansNeckRisk FactorsAorta, Abdominal / diagnostic imagingAorta, Abdominal / surgeryAortic Aneurysm, Abdominal / complicationsAortic Aneurysm, Abdominal / surgery*Aortic Rupture / epidemiology*Aortic Rupture / etiologyAortographyComputed Tomography AngiographyDilatation, Pathologic / diagnosisDilatation, Pathologic / epidemiologyDilatation, Pathologic / etiologyForeign-Body Migration / epidemiology*Foreign-Body Migration / etiologyRetrospective StudiesRisk FactorsStents / adverse effectsTreatment OutcomeObjective: Aortic neck dilatation (AND) occurs after endovascular aneurysm repair (EVAR) with self expanding stent grafts (SESs). Whether it continues, ultimately exceeding the endograft diameter leading to abdominal aortic aneurysm (AAA) rupture, remains uncertain. Dynamics, risk factors, and clinical relevance of AND were investigated after EVAR with standard SESs. Methods: All intact EVAR patients treated from 2000 to 2015 at a tertiary institution were included. Demographic, anatomical, and device related characteristics were investigated as risk factors for AND. Outer to outer diameters were measured at a single standardised aortic level on reconstructed computed tomography (CT) images. Results: A total of 460 patients were included (median follow up 5.2 years, interquartile range [IQR] 3.0, 7.7 years; CT imaging follow up 3.3 years, IQR 1.3, 5.4). Baseline neck diameter was 24 mm (IQR 22, 26) and increased 11.1% (IQR 1.5%, 21.9%) at last CT imaging. Endograft oversizing was 20.0% (IQR 13.6, 28.0). AND was greater during the first year (5.2% [IQR 0, 11.7]) decreasing subsequently (two to four years to 1.4%/year [IQR 0.0, 4.5%], p ≤ .001) and was associated with suprarenal fixation endografts (t value = 7.9, p < .001) and oversizing (t value = 4.4, p < .001). AND exceeding the endograft was 3.5% (95% CI 2.2% - 4.8%) and 14.4% (95% CI 11.0% - 17.8%) at five and eight years, respectively. Excessive AND was associated with baseline neck diameter (OR 1.2/mm, 95% CI 1.05 - 1.41) while the Excluder endograft had a protective effect (OR 0.15, 95% CI 0.04 - 0.58). Excessive AND was associated with type 1A endoleak (HR 3.3, 95% CI 1.1 - 9.7) and endograft migration > 5 mm (HR 3.1, 95% CI 1.4 - 6.9). Conclusion: AND after EVAR with SES is associated with endograft oversizing and radial force but decelerates after the first post-operative year. Baseline aortic neck diameter and suprarenal stent bearing endografts were associated with an increased risk of AND beyond nominal stent graft diameter. However, it remains unclear whether patient selection, differences in endograft radial force or the suprarenal stent are accountable for this difference.ElsevierRepositório do Centro Hospitalar Universitário de Lisboa Central, EPEOliveira, NOliveira-Pinto, JRijn, MBaart, SRaa, SHoeks, SBastos Gonçalves, FVerhagen, H2022-06-15T14:43:18Z20212021-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/4119engEur J Vasc Endovasc Surg. 2021 Jul;62(1):26-35.10.1016/j.ejvs.2021.03.020.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-10T09:45:24Zoai:repositorio.chlc.min-saude.pt:10400.17/4119Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:21:27.695539Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
title |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
spellingShingle |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair Oliveira, N HSM CIR VASC Aged Female Male Humans Neck Risk Factors Aorta, Abdominal / diagnostic imaging Aorta, Abdominal / surgery Aortic Aneurysm, Abdominal / complications Aortic Aneurysm, Abdominal / surgery* Aortic Rupture / epidemiology* Aortic Rupture / etiology Aortography Computed Tomography Angiography Dilatation, Pathologic / diagnosis Dilatation, Pathologic / epidemiology Dilatation, Pathologic / etiology Foreign-Body Migration / epidemiology* Foreign-Body Migration / etiology Retrospective Studies Risk Factors Stents / adverse effects Treatment Outcome |
title_short |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
title_full |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
title_fullStr |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
title_full_unstemmed |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
title_sort |
Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair |
author |
Oliveira, N |
author_facet |
Oliveira, N Oliveira-Pinto, J Rijn, M Baart, S Raa, S Hoeks, S Bastos Gonçalves, F Verhagen, H |
author_role |
author |
author2 |
Oliveira-Pinto, J Rijn, M Baart, S Raa, S Hoeks, S Bastos Gonçalves, F Verhagen, H |
author2_role |
author author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE |
dc.contributor.author.fl_str_mv |
Oliveira, N Oliveira-Pinto, J Rijn, M Baart, S Raa, S Hoeks, S Bastos Gonçalves, F Verhagen, H |
dc.subject.por.fl_str_mv |
HSM CIR VASC Aged Female Male Humans Neck Risk Factors Aorta, Abdominal / diagnostic imaging Aorta, Abdominal / surgery Aortic Aneurysm, Abdominal / complications Aortic Aneurysm, Abdominal / surgery* Aortic Rupture / epidemiology* Aortic Rupture / etiology Aortography Computed Tomography Angiography Dilatation, Pathologic / diagnosis Dilatation, Pathologic / epidemiology Dilatation, Pathologic / etiology Foreign-Body Migration / epidemiology* Foreign-Body Migration / etiology Retrospective Studies Risk Factors Stents / adverse effects Treatment Outcome |
topic |
HSM CIR VASC Aged Female Male Humans Neck Risk Factors Aorta, Abdominal / diagnostic imaging Aorta, Abdominal / surgery Aortic Aneurysm, Abdominal / complications Aortic Aneurysm, Abdominal / surgery* Aortic Rupture / epidemiology* Aortic Rupture / etiology Aortography Computed Tomography Angiography Dilatation, Pathologic / diagnosis Dilatation, Pathologic / epidemiology Dilatation, Pathologic / etiology Foreign-Body Migration / epidemiology* Foreign-Body Migration / etiology Retrospective Studies Risk Factors Stents / adverse effects Treatment Outcome |
description |
Objective: Aortic neck dilatation (AND) occurs after endovascular aneurysm repair (EVAR) with self expanding stent grafts (SESs). Whether it continues, ultimately exceeding the endograft diameter leading to abdominal aortic aneurysm (AAA) rupture, remains uncertain. Dynamics, risk factors, and clinical relevance of AND were investigated after EVAR with standard SESs. Methods: All intact EVAR patients treated from 2000 to 2015 at a tertiary institution were included. Demographic, anatomical, and device related characteristics were investigated as risk factors for AND. Outer to outer diameters were measured at a single standardised aortic level on reconstructed computed tomography (CT) images. Results: A total of 460 patients were included (median follow up 5.2 years, interquartile range [IQR] 3.0, 7.7 years; CT imaging follow up 3.3 years, IQR 1.3, 5.4). Baseline neck diameter was 24 mm (IQR 22, 26) and increased 11.1% (IQR 1.5%, 21.9%) at last CT imaging. Endograft oversizing was 20.0% (IQR 13.6, 28.0). AND was greater during the first year (5.2% [IQR 0, 11.7]) decreasing subsequently (two to four years to 1.4%/year [IQR 0.0, 4.5%], p ≤ .001) and was associated with suprarenal fixation endografts (t value = 7.9, p < .001) and oversizing (t value = 4.4, p < .001). AND exceeding the endograft was 3.5% (95% CI 2.2% - 4.8%) and 14.4% (95% CI 11.0% - 17.8%) at five and eight years, respectively. Excessive AND was associated with baseline neck diameter (OR 1.2/mm, 95% CI 1.05 - 1.41) while the Excluder endograft had a protective effect (OR 0.15, 95% CI 0.04 - 0.58). Excessive AND was associated with type 1A endoleak (HR 3.3, 95% CI 1.1 - 9.7) and endograft migration > 5 mm (HR 3.1, 95% CI 1.4 - 6.9). Conclusion: AND after EVAR with SES is associated with endograft oversizing and radial force but decelerates after the first post-operative year. Baseline aortic neck diameter and suprarenal stent bearing endografts were associated with an increased risk of AND beyond nominal stent graft diameter. However, it remains unclear whether patient selection, differences in endograft radial force or the suprarenal stent are accountable for this difference. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021 2021-01-01T00:00:00Z 2022-06-15T14:43:18Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.17/4119 |
url |
http://hdl.handle.net/10400.17/4119 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Eur J Vasc Endovasc Surg. 2021 Jul;62(1):26-35. 10.1016/j.ejvs.2021.03.020. |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131310059421696 |