Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.9/3608 |
Resumo: | ABSTRACT: A char (GC) obtained from the co-gasification of rice husk and polyethylene was used in a fixed-bed column with continuous flow for Cr(III) removal assays from synthetic and industrial wastewaters. For comparison purposes, a commercial activated carbon (CAC) was also used. The best experimental conditions in the continuous removal assays were the following ones: Cr(III) inflow concentration = 5 mg L-1, feed flow rate = 3 mL min(-1), mass of adsorbent in the column = 0.8 g, and inflow temperature = 50 degrees C. Under these conditions, the highest uptake capacities were 1.60 and 2.14 mg g(-1) in the synthetic solution, and 3.25 and 7.83 mg g(-1) in the industrial wastewater, for GC and CAC, respectively. These results are different from those obtained under batch conditions in which GC performed better than CAC. Cr(III) removal by both adsorbents occurred due to precipitation, but CAC presented a slightly higher amount of Cr(III) removed due to its highest porosity. The regeneration of GC and CAC was also studied, but both adsorbents showed no capacity to be used in more than one cycle. This study highlighted the importance of studying Cr(III) removal under continuous conditions, as the removal mechanisms may be completely different from the batch assays, affecting the adsorbents' performance. |
id |
RCAP_2a4f62f546cb2a3a3566c368f1e47fbb |
---|---|
oai_identifier_str |
oai:repositorio.lneg.pt:10400.9/3608 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification charRice wastesWastewaterCo-gasificationChromiumAdsorptionActivated carbonsIndustrial wastewatersABSTRACT: A char (GC) obtained from the co-gasification of rice husk and polyethylene was used in a fixed-bed column with continuous flow for Cr(III) removal assays from synthetic and industrial wastewaters. For comparison purposes, a commercial activated carbon (CAC) was also used. The best experimental conditions in the continuous removal assays were the following ones: Cr(III) inflow concentration = 5 mg L-1, feed flow rate = 3 mL min(-1), mass of adsorbent in the column = 0.8 g, and inflow temperature = 50 degrees C. Under these conditions, the highest uptake capacities were 1.60 and 2.14 mg g(-1) in the synthetic solution, and 3.25 and 7.83 mg g(-1) in the industrial wastewater, for GC and CAC, respectively. These results are different from those obtained under batch conditions in which GC performed better than CAC. Cr(III) removal by both adsorbents occurred due to precipitation, but CAC presented a slightly higher amount of Cr(III) removed due to its highest porosity. The regeneration of GC and CAC was also studied, but both adsorbents showed no capacity to be used in more than one cycle. This study highlighted the importance of studying Cr(III) removal under continuous conditions, as the removal mechanisms may be completely different from the batch assays, affecting the adsorbents' performance.SpringerRepositório do LNEGDias, DiogoBernardo, MariaPinto, FilomenaFonseca, Isabel MariaLapa, Nuno2021-11-18T17:05:03Z2021-102021-10-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.9/3608engDias, D... [et.al.] - Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char. In: International Journal of Environmental Science and Technology, 2021 [Early Access]1735-147210.1007/s13762-021-03690-81735-2630info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-13T06:26:52Zoai:repositorio.lneg.pt:10400.9/3608Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:36:49.008242Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
title |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
spellingShingle |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char Dias, Diogo Rice wastes Wastewater Co-gasification Chromium Adsorption Activated carbons Industrial wastewaters |
title_short |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
title_full |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
title_fullStr |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
title_full_unstemmed |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
title_sort |
Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char |
author |
Dias, Diogo |
author_facet |
Dias, Diogo Bernardo, Maria Pinto, Filomena Fonseca, Isabel Maria Lapa, Nuno |
author_role |
author |
author2 |
Bernardo, Maria Pinto, Filomena Fonseca, Isabel Maria Lapa, Nuno |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Repositório do LNEG |
dc.contributor.author.fl_str_mv |
Dias, Diogo Bernardo, Maria Pinto, Filomena Fonseca, Isabel Maria Lapa, Nuno |
dc.subject.por.fl_str_mv |
Rice wastes Wastewater Co-gasification Chromium Adsorption Activated carbons Industrial wastewaters |
topic |
Rice wastes Wastewater Co-gasification Chromium Adsorption Activated carbons Industrial wastewaters |
description |
ABSTRACT: A char (GC) obtained from the co-gasification of rice husk and polyethylene was used in a fixed-bed column with continuous flow for Cr(III) removal assays from synthetic and industrial wastewaters. For comparison purposes, a commercial activated carbon (CAC) was also used. The best experimental conditions in the continuous removal assays were the following ones: Cr(III) inflow concentration = 5 mg L-1, feed flow rate = 3 mL min(-1), mass of adsorbent in the column = 0.8 g, and inflow temperature = 50 degrees C. Under these conditions, the highest uptake capacities were 1.60 and 2.14 mg g(-1) in the synthetic solution, and 3.25 and 7.83 mg g(-1) in the industrial wastewater, for GC and CAC, respectively. These results are different from those obtained under batch conditions in which GC performed better than CAC. Cr(III) removal by both adsorbents occurred due to precipitation, but CAC presented a slightly higher amount of Cr(III) removed due to its highest porosity. The regeneration of GC and CAC was also studied, but both adsorbents showed no capacity to be used in more than one cycle. This study highlighted the importance of studying Cr(III) removal under continuous conditions, as the removal mechanisms may be completely different from the batch assays, affecting the adsorbents' performance. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-11-18T17:05:03Z 2021-10 2021-10-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.9/3608 |
url |
http://hdl.handle.net/10400.9/3608 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Dias, D... [et.al.] - Cr(III) dynamic removal in a fixed-bed column by using a co-gasification char. In: International Journal of Environmental Science and Technology, 2021 [Early Access] 1735-1472 10.1007/s13762-021-03690-8 1735-2630 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Springer |
publisher.none.fl_str_mv |
Springer |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130234906214400 |