Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10451/45239 |
Resumo: | © 2016 Faria et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
id |
RCAP_2c62a48b9c00401eb6555d94e63588d8 |
---|---|
oai_identifier_str |
oai:repositorio.ul.pt:10451/45239 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular supportAphakiaDislocated IOLFoldable iris-claw IOL© 2016 Faria et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).Summary: Iris-claw intraocular lens (ICIOL) for aphakia needs a large 5.4 mm corneal incision for its implantation. The technique needs corneal suture, associated with some postoperative astigmatism. Foldable ICIOL is used in phakic patients undergoing refractive surgery and has the advantage of a sutureless small corneal incision. We report a case of a high myopic patient with dislocated intraocular lens (IOL) and no capsular support. Dislocated IOL with its capsular bag was released with three-port, 23-gauge vitrectomy; placed in the anterior chamber; sliced; and extruded through a 3.2-mm corneal incision, where a foldable ICIOL was introduced and placed retropupillary. This technique achieved a stable fixation of the IOL. Retropupillary implantation of a foldable ICIOL on aphakic patients has advantages over that of a polymethylmethacrylate (PMMA) ICIOL due to smaller corneal incision. The technique may be safe and easy to perform. Purpose: The purpose of this report was to describe the technique of retropupillary implantation of a foldable iris-claw intraocular lens (ICIOL) in a patient with dislocated intraocular lens (IOL) in mid vitreous cavity. Methods: Foldable ICIOL (Artiflex® Myopia Model 401) is used in phakic patients undergoing refractive surgery and has the advantage of a sutureless small corneal incision. We report a case of a high myopic patient with dislocated IOL and no capsular support. The calculation was a -5.0 D IOL for retropupilar position, and a foldable ICIOL was introduced through a 3.2-mm corneal incision and placed retropupillary. Results: The technique was easy to achieve. IOL was properly positioned retropupillary and maintained stable. There was no ocular hypertension and no anterior chamber flare or iris atrophy. Conclusion: Retropupillary implantation of a foldable ICIOL on aphakic patients has advantages over that of a PMMA ICIOL due to smaller corneal incision. The technique may be safe and easy to perform.Dove Medical PressRepositório da Universidade de LisboaFaria, Mun YuehFerreira, Nuno PintoGama, IvoPinto, Joana MedeirosCanastro, MárioMonteiro Grillo, Manuel2020-12-10T13:41:49Z20162016-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10451/45239engInternational Medical Case Reports Journal 2016:9 337–310.2147/IMCRJ.S1193471179-142Xinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-08T16:46:55Zoai:repositorio.ul.pt:10451/45239Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:57:43.984587Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
title |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
spellingShingle |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support Faria, Mun Yueh Aphakia Dislocated IOL Foldable iris-claw IOL |
title_short |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
title_full |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
title_fullStr |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
title_full_unstemmed |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
title_sort |
Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support |
author |
Faria, Mun Yueh |
author_facet |
Faria, Mun Yueh Ferreira, Nuno Pinto Gama, Ivo Pinto, Joana Medeiros Canastro, Mário Monteiro Grillo, Manuel |
author_role |
author |
author2 |
Ferreira, Nuno Pinto Gama, Ivo Pinto, Joana Medeiros Canastro, Mário Monteiro Grillo, Manuel |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Repositório da Universidade de Lisboa |
dc.contributor.author.fl_str_mv |
Faria, Mun Yueh Ferreira, Nuno Pinto Gama, Ivo Pinto, Joana Medeiros Canastro, Mário Monteiro Grillo, Manuel |
dc.subject.por.fl_str_mv |
Aphakia Dislocated IOL Foldable iris-claw IOL |
topic |
Aphakia Dislocated IOL Foldable iris-claw IOL |
description |
© 2016 Faria et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016 2016-01-01T00:00:00Z 2020-12-10T13:41:49Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10451/45239 |
url |
http://hdl.handle.net/10451/45239 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
International Medical Case Reports Journal 2016:9 337–3 10.2147/IMCRJ.S119347 1179-142X |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Dove Medical Press |
publisher.none.fl_str_mv |
Dove Medical Press |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799134521567739904 |