Non-invasive postural assessment of the spine in the sagittal plane: a systematic review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2016000200016 |
Resumo: | The objective of this review was to examine the scientific evidence regarding the aspects of validation in non-invasive methods of assessing the spine in the sagittal plane. A systematic search was conducted in following data bases Scopus, Science Direct, PubMed and Medline. To be included the papers must have: conducted a non-invasive assessment of thoracic kyphosis and/or lumbar lordosis; evaluated at least one aspect of validity; been written in English; and been published in the previously three decades. Papers that score less than three in the QUADAS scale were excluded. Initially, 70 articles were pre-selected. Of this, 52 were finally included as they met the quality criterion. Based on this review, the following techniques/instruments were found to present satisfactory results for all aspects of validity in the assessment of thoracic kyphosis: photogrammetry, flexible ruler, archometer, and DeBrunnerskyphometer. Similarly, photogrammetry, inclinometer, flexible ruler, archometer and kypholordometer were found to present satisfactory results in the assessment of lumbar lordosis. Therefore, it is suggested that these instruments be adopted as first choice for evaluating the spine in the sagittal plane, since they present adequate reproducibility and concurrent validity. |
id |
RCAP_2cdefed60ecf2cad9ed0a2e0d2a4b03e |
---|---|
oai_identifier_str |
oai:scielo:S1646-107X2016000200016 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic reviewevaluationposturemethodsreproducibility of resultsvalidity of testsThe objective of this review was to examine the scientific evidence regarding the aspects of validation in non-invasive methods of assessing the spine in the sagittal plane. A systematic search was conducted in following data bases Scopus, Science Direct, PubMed and Medline. To be included the papers must have: conducted a non-invasive assessment of thoracic kyphosis and/or lumbar lordosis; evaluated at least one aspect of validity; been written in English; and been published in the previously three decades. Papers that score less than three in the QUADAS scale were excluded. Initially, 70 articles were pre-selected. Of this, 52 were finally included as they met the quality criterion. Based on this review, the following techniques/instruments were found to present satisfactory results for all aspects of validity in the assessment of thoracic kyphosis: photogrammetry, flexible ruler, archometer, and DeBrunnerskyphometer. Similarly, photogrammetry, inclinometer, flexible ruler, archometer and kypholordometer were found to present satisfactory results in the assessment of lumbar lordosis. Therefore, it is suggested that these instruments be adopted as first choice for evaluating the spine in the sagittal plane, since they present adequate reproducibility and concurrent validity.Edições Desafio Singular2016-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2016000200016Motricidade v.12 n.2 2016reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2016000200016Sedrez,Juliana AdamiCandotti,Cláudia TarragôFurlanetto,Tássia SilveiraLoss,Jefferson Fagundesinfo:eu-repo/semantics/openAccess2024-02-06T17:20:05Zoai:scielo:S1646-107X2016000200016Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:27:36.431695Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
title |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
spellingShingle |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review Sedrez,Juliana Adami evaluation posture methods reproducibility of results validity of tests |
title_short |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
title_full |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
title_fullStr |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
title_full_unstemmed |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
title_sort |
Non-invasive postural assessment of the spine in the sagittal plane: a systematic review |
author |
Sedrez,Juliana Adami |
author_facet |
Sedrez,Juliana Adami Candotti,Cláudia Tarragô Furlanetto,Tássia Silveira Loss,Jefferson Fagundes |
author_role |
author |
author2 |
Candotti,Cláudia Tarragô Furlanetto,Tássia Silveira Loss,Jefferson Fagundes |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Sedrez,Juliana Adami Candotti,Cláudia Tarragô Furlanetto,Tássia Silveira Loss,Jefferson Fagundes |
dc.subject.por.fl_str_mv |
evaluation posture methods reproducibility of results validity of tests |
topic |
evaluation posture methods reproducibility of results validity of tests |
description |
The objective of this review was to examine the scientific evidence regarding the aspects of validation in non-invasive methods of assessing the spine in the sagittal plane. A systematic search was conducted in following data bases Scopus, Science Direct, PubMed and Medline. To be included the papers must have: conducted a non-invasive assessment of thoracic kyphosis and/or lumbar lordosis; evaluated at least one aspect of validity; been written in English; and been published in the previously three decades. Papers that score less than three in the QUADAS scale were excluded. Initially, 70 articles were pre-selected. Of this, 52 were finally included as they met the quality criterion. Based on this review, the following techniques/instruments were found to present satisfactory results for all aspects of validity in the assessment of thoracic kyphosis: photogrammetry, flexible ruler, archometer, and DeBrunnerskyphometer. Similarly, photogrammetry, inclinometer, flexible ruler, archometer and kypholordometer were found to present satisfactory results in the assessment of lumbar lordosis. Therefore, it is suggested that these instruments be adopted as first choice for evaluating the spine in the sagittal plane, since they present adequate reproducibility and concurrent validity. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-06-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2016000200016 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2016000200016 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2016000200016 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Edições Desafio Singular |
publisher.none.fl_str_mv |
Edições Desafio Singular |
dc.source.none.fl_str_mv |
Motricidade v.12 n.2 2016 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137348335697920 |