Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.2/2039 |
Resumo: | The present article describes a novel vibrating-wire viscometer that has been shown to be able to measure viscosities up to 135 mPaâs, after calibration against water at 20 °C, to provide direct traceability to the primary reference for viscosity. For the purpose of validating the instrument, measurements of the viscosity of some selected fluids, including standard reference liquids with viscosity on the order of 100 mPaâs at 20 °C and 2,2,4-trimethylpentane with a viscosity of about 0.5 mPaâs at the same temperature, were performed. The results obtained show that the instrument is capable of performing viscosity measurements with an estimated overall uncertainty better than (0.8% over the range of (0.5 to 135) mPa's. |
id |
RCAP_3310d186a39216bb7afabe0be5a28954 |
---|---|
oai_identifier_str |
oai:repositorioaberto.uab.pt:10400.2/2039 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa'sVibrating-wire viscometerViscosity measurementsStandard reference liquidsThe present article describes a novel vibrating-wire viscometer that has been shown to be able to measure viscosities up to 135 mPaâs, after calibration against water at 20 °C, to provide direct traceability to the primary reference for viscosity. For the purpose of validating the instrument, measurements of the viscosity of some selected fluids, including standard reference liquids with viscosity on the order of 100 mPaâs at 20 °C and 2,2,4-trimethylpentane with a viscosity of about 0.5 mPaâs at the same temperature, were performed. The results obtained show that the instrument is capable of performing viscosity measurements with an estimated overall uncertainty better than (0.8% over the range of (0.5 to 135) mPa's.American Chemical SocietyRepositório AbertoOliveira, Carla Padrel deCaetano, Fernando J. P.Fareleira, João M. N. A.Wakeham, William A.2012-01-19T09:49:48Z20052005-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.2/2039engOliveira, Carla Padrel de [et al.] - Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's. "Journal of Chemical & Engineering Data" [Em linha]. ISSN 0021-9568 (Print) 1520-5134 (Online). Vol. 50, nº 1 (2005), p. 201-2050021-9568info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-16T15:15:20Zoai:repositorioaberto.uab.pt:10400.2/2039Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T22:43:39.164563Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
title |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
spellingShingle |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's Oliveira, Carla Padrel de Vibrating-wire viscometer Viscosity measurements Standard reference liquids |
title_short |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
title_full |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
title_fullStr |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
title_full_unstemmed |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
title_sort |
Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's |
author |
Oliveira, Carla Padrel de |
author_facet |
Oliveira, Carla Padrel de Caetano, Fernando J. P. Fareleira, João M. N. A. Wakeham, William A. |
author_role |
author |
author2 |
Caetano, Fernando J. P. Fareleira, João M. N. A. Wakeham, William A. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Repositório Aberto |
dc.contributor.author.fl_str_mv |
Oliveira, Carla Padrel de Caetano, Fernando J. P. Fareleira, João M. N. A. Wakeham, William A. |
dc.subject.por.fl_str_mv |
Vibrating-wire viscometer Viscosity measurements Standard reference liquids |
topic |
Vibrating-wire viscometer Viscosity measurements Standard reference liquids |
description |
The present article describes a novel vibrating-wire viscometer that has been shown to be able to measure viscosities up to 135 mPaâs, after calibration against water at 20 °C, to provide direct traceability to the primary reference for viscosity. For the purpose of validating the instrument, measurements of the viscosity of some selected fluids, including standard reference liquids with viscosity on the order of 100 mPaâs at 20 °C and 2,2,4-trimethylpentane with a viscosity of about 0.5 mPaâs at the same temperature, were performed. The results obtained show that the instrument is capable of performing viscosity measurements with an estimated overall uncertainty better than (0.8% over the range of (0.5 to 135) mPa's. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005 2005-01-01T00:00:00Z 2012-01-19T09:49:48Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.2/2039 |
url |
http://hdl.handle.net/10400.2/2039 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Oliveira, Carla Padrel de [et al.] - Validation of a vibrating-wire viscometer: measurements in the range of 0.5 to 135 mPa's. "Journal of Chemical & Engineering Data" [Em linha]. ISSN 0021-9568 (Print) 1520-5134 (Online). Vol. 50, nº 1 (2005), p. 201-205 0021-9568 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
American Chemical Society |
publisher.none.fl_str_mv |
American Chemical Society |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817554392236163072 |