Validation of automated apparatus for upper limb velocity testing
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2018000300011 |
Resumo: | The purpose of this paper was to validate the ability of automated devices to measure the velocity of the upper limbs. Thus, 144 students, from 8 to 17 years old, both sexes, participated in the study in a social project in the city of Natal/RN. The Automated Tapping Test (AATT) was developed following the dimensions of the original EUROFIT test, but built out of metal parts, so that the calibration was more accurate and could be read as an electronic signal by the integrated circuit. The upper limb velocity test was applied in three steps: before performing the original test, all participants underwent a laterality check and then motor practice similar to the original test. After 30 minutes, the first step in the pattern established by the EUROFIT test battery was performed and 30 minutes later, the third stage, with the AATT. The measurement reliability of the automated apparatus was tested through intraclass correlations and a strong intraclass interaction coefficient of r = 0.901 was found. In conclusion, the AATT was found to be accurate and efficient as to what it is proposed to evaluate, being able to minimize the intra-evaluator error and to assist professionals in the sports. |
id |
RCAP_34f303f4ff1a0c0aefbd68e0dc0bfa70 |
---|---|
oai_identifier_str |
oai:scielo:S1646-107X2018000300011 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Validation of automated apparatus for upper limb velocity testingdevice validationmotor evaluationplate striketapping testvelocity of upper limbsThe purpose of this paper was to validate the ability of automated devices to measure the velocity of the upper limbs. Thus, 144 students, from 8 to 17 years old, both sexes, participated in the study in a social project in the city of Natal/RN. The Automated Tapping Test (AATT) was developed following the dimensions of the original EUROFIT test, but built out of metal parts, so that the calibration was more accurate and could be read as an electronic signal by the integrated circuit. The upper limb velocity test was applied in three steps: before performing the original test, all participants underwent a laterality check and then motor practice similar to the original test. After 30 minutes, the first step in the pattern established by the EUROFIT test battery was performed and 30 minutes later, the third stage, with the AATT. The measurement reliability of the automated apparatus was tested through intraclass correlations and a strong intraclass interaction coefficient of r = 0.901 was found. In conclusion, the AATT was found to be accurate and efficient as to what it is proposed to evaluate, being able to minimize the intra-evaluator error and to assist professionals in the sports.Edições Desafio Singular2018-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2018000300011Motricidade v.14 n.4 2018reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2018000300011Silva,Leandro Medeiros daAidar,Felipe JoséMatos,Dihogo Gama deSantana,Eduardo EstevanDantas,Matheus PeixotoSantos,Petrus Gantois Massa Dias dosDantas,Paulo MoreiraCabra,Breno Guilherme de Araújo Tinôcoinfo:eu-repo/semantics/openAccess2024-02-06T17:20:20Zoai:scielo:S1646-107X2018000300011Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:27:46.045659Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Validation of automated apparatus for upper limb velocity testing |
title |
Validation of automated apparatus for upper limb velocity testing |
spellingShingle |
Validation of automated apparatus for upper limb velocity testing Silva,Leandro Medeiros da device validation motor evaluation plate strike tapping test velocity of upper limbs |
title_short |
Validation of automated apparatus for upper limb velocity testing |
title_full |
Validation of automated apparatus for upper limb velocity testing |
title_fullStr |
Validation of automated apparatus for upper limb velocity testing |
title_full_unstemmed |
Validation of automated apparatus for upper limb velocity testing |
title_sort |
Validation of automated apparatus for upper limb velocity testing |
author |
Silva,Leandro Medeiros da |
author_facet |
Silva,Leandro Medeiros da Aidar,Felipe José Matos,Dihogo Gama de Santana,Eduardo Estevan Dantas,Matheus Peixoto Santos,Petrus Gantois Massa Dias dos Dantas,Paulo Moreira Cabra,Breno Guilherme de Araújo Tinôco |
author_role |
author |
author2 |
Aidar,Felipe José Matos,Dihogo Gama de Santana,Eduardo Estevan Dantas,Matheus Peixoto Santos,Petrus Gantois Massa Dias dos Dantas,Paulo Moreira Cabra,Breno Guilherme de Araújo Tinôco |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Silva,Leandro Medeiros da Aidar,Felipe José Matos,Dihogo Gama de Santana,Eduardo Estevan Dantas,Matheus Peixoto Santos,Petrus Gantois Massa Dias dos Dantas,Paulo Moreira Cabra,Breno Guilherme de Araújo Tinôco |
dc.subject.por.fl_str_mv |
device validation motor evaluation plate strike tapping test velocity of upper limbs |
topic |
device validation motor evaluation plate strike tapping test velocity of upper limbs |
description |
The purpose of this paper was to validate the ability of automated devices to measure the velocity of the upper limbs. Thus, 144 students, from 8 to 17 years old, both sexes, participated in the study in a social project in the city of Natal/RN. The Automated Tapping Test (AATT) was developed following the dimensions of the original EUROFIT test, but built out of metal parts, so that the calibration was more accurate and could be read as an electronic signal by the integrated circuit. The upper limb velocity test was applied in three steps: before performing the original test, all participants underwent a laterality check and then motor practice similar to the original test. After 30 minutes, the first step in the pattern established by the EUROFIT test battery was performed and 30 minutes later, the third stage, with the AATT. The measurement reliability of the automated apparatus was tested through intraclass correlations and a strong intraclass interaction coefficient of r = 0.901 was found. In conclusion, the AATT was found to be accurate and efficient as to what it is proposed to evaluate, being able to minimize the intra-evaluator error and to assist professionals in the sports. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-12-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2018000300011 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2018000300011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-107X2018000300011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Edições Desafio Singular |
publisher.none.fl_str_mv |
Edições Desafio Singular |
dc.source.none.fl_str_mv |
Motricidade v.14 n.4 2018 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137349473402880 |