Fatigue strength of shear connectors

Detalhes bibliográficos
Autor(a) principal: Xie, En
Data de Publicação: 2011
Outros Autores: Valente, Isabel
Tipo de documento: Relatório
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/15231
Resumo: Nowadays steel and concrete composite beams are widely applied in structures mainly subjected to dynamic loads, such as railway and road bridges exposed to traffic loads and industrial crane runways exposed to folk-lift truck loads, the fatigue resistance of these structures must be generally and carefully verified. And normally the shear forces between concrete flange and steel beams are all transferred by different kinds of shear connectors, fatigue failure of composite beam may happen on shear connectors. So the fatigue resistance of shear connectors in composite beams is significant for the safe of whole structure and needed to be well investigated. The fatigue strength of shear connectors could be explained in three ways, the fatigue endurance described by the relationships between stress range (S) and number of cycles (N), the static residual strength after a certain number of cycling loading, and the slip behavior during the cycling tests. S-N curves which widely used for steel fatigue assessment are also useful for shear connectors. Although there are already S-N curves for headed steel studs in Eurocodes and AASHTO, they are normally available for common studs. Whether these S-N curves applicable for large diameter studs or studs embedded in high strength concrete or other kind shear connectors is questionable. And the factors influencing fatigue life of shear connectors are needed more research. Furthermore, for the fatigue life assessment of existing structures, it is important to attain the residual strength after a certain service life or the principles of slip developing behavior during the service life. Then it is possible to assess how long the shear connectors could still service.
id RCAP_36664c7f12418e1dd803ce9816aca664
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/15231
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Fatigue strength of shear connectorsFatigueShear connectorsNowadays steel and concrete composite beams are widely applied in structures mainly subjected to dynamic loads, such as railway and road bridges exposed to traffic loads and industrial crane runways exposed to folk-lift truck loads, the fatigue resistance of these structures must be generally and carefully verified. And normally the shear forces between concrete flange and steel beams are all transferred by different kinds of shear connectors, fatigue failure of composite beam may happen on shear connectors. So the fatigue resistance of shear connectors in composite beams is significant for the safe of whole structure and needed to be well investigated. The fatigue strength of shear connectors could be explained in three ways, the fatigue endurance described by the relationships between stress range (S) and number of cycles (N), the static residual strength after a certain number of cycling loading, and the slip behavior during the cycling tests. S-N curves which widely used for steel fatigue assessment are also useful for shear connectors. Although there are already S-N curves for headed steel studs in Eurocodes and AASHTO, they are normally available for common studs. Whether these S-N curves applicable for large diameter studs or studs embedded in high strength concrete or other kind shear connectors is questionable. And the factors influencing fatigue life of shear connectors are needed more research. Furthermore, for the fatigue life assessment of existing structures, it is important to attain the residual strength after a certain service life or the principles of slip developing behavior during the service life. Then it is possible to assess how long the shear connectors could still service.Universidade do MinhoXie, EnValente, Isabel2011-022011-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/reportapplication/pdfhttp://hdl.handle.net/1822/15231enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:38:48Zoai:repositorium.sdum.uminho.pt:1822/15231Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:35:19.445498Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Fatigue strength of shear connectors
title Fatigue strength of shear connectors
spellingShingle Fatigue strength of shear connectors
Xie, En
Fatigue
Shear connectors
title_short Fatigue strength of shear connectors
title_full Fatigue strength of shear connectors
title_fullStr Fatigue strength of shear connectors
title_full_unstemmed Fatigue strength of shear connectors
title_sort Fatigue strength of shear connectors
author Xie, En
author_facet Xie, En
Valente, Isabel
author_role author
author2 Valente, Isabel
author2_role author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Xie, En
Valente, Isabel
dc.subject.por.fl_str_mv Fatigue
Shear connectors
topic Fatigue
Shear connectors
description Nowadays steel and concrete composite beams are widely applied in structures mainly subjected to dynamic loads, such as railway and road bridges exposed to traffic loads and industrial crane runways exposed to folk-lift truck loads, the fatigue resistance of these structures must be generally and carefully verified. And normally the shear forces between concrete flange and steel beams are all transferred by different kinds of shear connectors, fatigue failure of composite beam may happen on shear connectors. So the fatigue resistance of shear connectors in composite beams is significant for the safe of whole structure and needed to be well investigated. The fatigue strength of shear connectors could be explained in three ways, the fatigue endurance described by the relationships between stress range (S) and number of cycles (N), the static residual strength after a certain number of cycling loading, and the slip behavior during the cycling tests. S-N curves which widely used for steel fatigue assessment are also useful for shear connectors. Although there are already S-N curves for headed steel studs in Eurocodes and AASHTO, they are normally available for common studs. Whether these S-N curves applicable for large diameter studs or studs embedded in high strength concrete or other kind shear connectors is questionable. And the factors influencing fatigue life of shear connectors are needed more research. Furthermore, for the fatigue life assessment of existing structures, it is important to attain the residual strength after a certain service life or the principles of slip developing behavior during the service life. Then it is possible to assess how long the shear connectors could still service.
publishDate 2011
dc.date.none.fl_str_mv 2011-02
2011-02-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/report
format report
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/15231
url http://hdl.handle.net/1822/15231
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132878306541568