Occupational exposure to formaldehyde: what reality in Portugal?

Detalhes bibliográficos
Autor(a) principal: Viegas, Susana
Data de Publicação: 2009
Outros Autores: Prista, João
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
DOI: 10.25758/set.294
Texto Completo: https://doi.org/10.25758/set.294
Resumo: Introduction – The widespread use of formaldehyde is mainly due to its high reactivity, lack of colour, purity in a commercial format, and also low cost. These characteristics put it among the 25 most abundant chemicals produced in the world. IARC, since 2006, classified formaldehyde in Group 1 (carcinogen) based on evidence that exposure to formaldehyde can cause nasopharyngeal cancer in humans. It was developed as an exploratory study with the purpose of obtaining information about occupational exposure reality to formaldehyde in Portugal. Methodology – Several formaldehyde concentration measurements were performed in 7 industrial units and in an anatomy and pathology laboratory. Environmental measurements were performed using Photo Ionization Detection (PID)  equipment. Results – The anatomy and pathology laboratory has the highest concentration value recorded and is larger than the reference limit (0.3 ppm). Also, 2 of 7 industrial units studied recorded maximum concentration values above 0,3 ppm. Conclusions – The anatomy and pathology laboratory was the occupational setting where formaldehyde occupational exposure was more criticized. The methodology used for environmental monitoring seems appropriate to the study objectives and related to the chemical agent's mode of action.
id RCAP_38b9c6db4111b520fd86682a87c025de
oai_identifier_str oai:journals.ipl.pt:article/713
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Occupational exposure to formaldehyde: what reality in Portugal?Exposição profissional a formaldeído: que realidade em Portugal?FormaldeídoExposição ocupacionalLaboratório de anatomia patológicaMonitorização ambientalFormaldehydeOccuparional exposureAnatomy and pathology laboratoryEnvironmental monitoringIntroduction – The widespread use of formaldehyde is mainly due to its high reactivity, lack of colour, purity in a commercial format, and also low cost. These characteristics put it among the 25 most abundant chemicals produced in the world. IARC, since 2006, classified formaldehyde in Group 1 (carcinogen) based on evidence that exposure to formaldehyde can cause nasopharyngeal cancer in humans. It was developed as an exploratory study with the purpose of obtaining information about occupational exposure reality to formaldehyde in Portugal. Methodology – Several formaldehyde concentration measurements were performed in 7 industrial units and in an anatomy and pathology laboratory. Environmental measurements were performed using Photo Ionization Detection (PID)  equipment. Results – The anatomy and pathology laboratory has the highest concentration value recorded and is larger than the reference limit (0.3 ppm). Also, 2 of 7 industrial units studied recorded maximum concentration values above 0,3 ppm. Conclusions – The anatomy and pathology laboratory was the occupational setting where formaldehyde occupational exposure was more criticized. The methodology used for environmental monitoring seems appropriate to the study objectives and related to the chemical agent's mode of action.Introdução – O formaldeído está enquadrado entre as 25 substâncias químicas mais abundantemente produzidas no mundo devendo-se essencialmente à sua elevada reactividade, ausência de cor, à sua pureza no formato comercial e, ainda, ao seu baixo custo. A IARC, desde 2006, classifica o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a formaldeído é susceptível de causar cancro nasofaríngeo em humanos. Desenvolveu-se um estudo de natureza exploratóra com o objectivo essencial de obter informação sobre a realidade da exposição profissional a formaldeído em Portugal. Igualmente, pretendeu-se conhecer a adequabilidade de uma nova metodologia de monitorização ambiental ao estudo da exposição  ocupacional a formaldeído.  Metodologia – Realizaram-se várias medições das concentrações de formaldeído em 7 unidades industriais e num laboratório hospitalar de anatomia patológica. As avaliações ambientais foram concretizadas com recurso a um equipamento de leitura directa que realiza a medição por Photo Ionization Detection (PID), com uma lâmpada de 11,7 eV. Resultados – No laboratório de anatomia patológica estudado foram registados valores de concentração superiores ao valor-limite de referência (0,3 ppm). Igualmente, em 2 das 7 unidades industriais estudadas foram registados valores de concentração máxima superiores a 0,3 ppm. Conclusões – Em  consonância com outros estudos, o laboratório de anatomia patológica apresentou-se como o contexto ocupacional onde a exposição a formaldeído apresenta as concentrações mais elevadas. A metodologia adoptada para monitorização ambiental parece adequar-se aos objectivos da presente investigação e relacionada com o modo de actuação do agente químico em estudo.Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)2009-11-15info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.25758/set.294https://doi.org/10.25758/set.294Saúde e Tecnologia; No. 04 (2009): Novembro 2009; 46-53Saúde & Tecnologia; N.º 04 (2009): Novembro 2009; 46-531646-9704reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://journals.ipl.pt/stecnologia/article/view/713https://journals.ipl.pt/stecnologia/article/view/713/608Direitos de Autor (c) 2022 Saúde & Tecnologiainfo:eu-repo/semantics/openAccessViegas, SusanaPrista, João2023-05-12T08:30:22Zoai:journals.ipl.pt:article/713Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:42:45.277303Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Occupational exposure to formaldehyde: what reality in Portugal?
Exposição profissional a formaldeído: que realidade em Portugal?
title Occupational exposure to formaldehyde: what reality in Portugal?
spellingShingle Occupational exposure to formaldehyde: what reality in Portugal?
Occupational exposure to formaldehyde: what reality in Portugal?
Viegas, Susana
Formaldeído
Exposição ocupacional
Laboratório de anatomia patológica
Monitorização ambiental
Formaldehyde
Occuparional exposure
Anatomy and pathology laboratory
Environmental monitoring
Viegas, Susana
Formaldeído
Exposição ocupacional
Laboratório de anatomia patológica
Monitorização ambiental
Formaldehyde
Occuparional exposure
Anatomy and pathology laboratory
Environmental monitoring
title_short Occupational exposure to formaldehyde: what reality in Portugal?
title_full Occupational exposure to formaldehyde: what reality in Portugal?
title_fullStr Occupational exposure to formaldehyde: what reality in Portugal?
Occupational exposure to formaldehyde: what reality in Portugal?
title_full_unstemmed Occupational exposure to formaldehyde: what reality in Portugal?
Occupational exposure to formaldehyde: what reality in Portugal?
title_sort Occupational exposure to formaldehyde: what reality in Portugal?
author Viegas, Susana
author_facet Viegas, Susana
Viegas, Susana
Prista, João
Prista, João
author_role author
author2 Prista, João
author2_role author
dc.contributor.author.fl_str_mv Viegas, Susana
Prista, João
dc.subject.por.fl_str_mv Formaldeído
Exposição ocupacional
Laboratório de anatomia patológica
Monitorização ambiental
Formaldehyde
Occuparional exposure
Anatomy and pathology laboratory
Environmental monitoring
topic Formaldeído
Exposição ocupacional
Laboratório de anatomia patológica
Monitorização ambiental
Formaldehyde
Occuparional exposure
Anatomy and pathology laboratory
Environmental monitoring
description Introduction – The widespread use of formaldehyde is mainly due to its high reactivity, lack of colour, purity in a commercial format, and also low cost. These characteristics put it among the 25 most abundant chemicals produced in the world. IARC, since 2006, classified formaldehyde in Group 1 (carcinogen) based on evidence that exposure to formaldehyde can cause nasopharyngeal cancer in humans. It was developed as an exploratory study with the purpose of obtaining information about occupational exposure reality to formaldehyde in Portugal. Methodology – Several formaldehyde concentration measurements were performed in 7 industrial units and in an anatomy and pathology laboratory. Environmental measurements were performed using Photo Ionization Detection (PID)  equipment. Results – The anatomy and pathology laboratory has the highest concentration value recorded and is larger than the reference limit (0.3 ppm). Also, 2 of 7 industrial units studied recorded maximum concentration values above 0,3 ppm. Conclusions – The anatomy and pathology laboratory was the occupational setting where formaldehyde occupational exposure was more criticized. The methodology used for environmental monitoring seems appropriate to the study objectives and related to the chemical agent's mode of action.
publishDate 2009
dc.date.none.fl_str_mv 2009-11-15
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.25758/set.294
https://doi.org/10.25758/set.294
url https://doi.org/10.25758/set.294
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://journals.ipl.pt/stecnologia/article/view/713
https://journals.ipl.pt/stecnologia/article/view/713/608
dc.rights.driver.fl_str_mv Direitos de Autor (c) 2022 Saúde & Tecnologia
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Direitos de Autor (c) 2022 Saúde & Tecnologia
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)
publisher.none.fl_str_mv Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)
dc.source.none.fl_str_mv Saúde e Tecnologia; No. 04 (2009): Novembro 2009; 46-53
Saúde & Tecnologia; N.º 04 (2009): Novembro 2009; 46-53
1646-9704
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1822181903190458369
dc.identifier.doi.none.fl_str_mv 10.25758/set.294