Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10773/37407 |
Resumo: | A 2D-Thick-COBRA based detector with 10 × 10 cm2 active area operating in Ne/CH4 (95/5) flow mode, was applied to X-ray Computed Tomography (CT). The CT system is based on a third generation scanner with the object motion provided by a stepper motor. Multi-slice acquisitions of a Poly(methyl methacrylate) phantom and of a sea snail were done and the cross-sectional images were used to perform tri-dimensional (3D) visualization of the objects. Both kind of images (cross-sectional and 3D) are presented. Cross-sectional images using energy intervals of the spectrum are shown. Also, a simulation study of the influence of discharges (intrinsic to the MicroPatterned Gaseous Detector operation) in the resulting cross-sectional image was done and presented, showing no significant influence on the final image |
id |
RCAP_39c4e554ad2de9d7b670839aeccdd4b4 |
---|---|
oai_identifier_str |
oai:ria.ua.pt:10773/37407 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4X-ray detectorsThick-COBRAMicropattern gaseous detectorsComputerized tomography(CT)A 2D-Thick-COBRA based detector with 10 × 10 cm2 active area operating in Ne/CH4 (95/5) flow mode, was applied to X-ray Computed Tomography (CT). The CT system is based on a third generation scanner with the object motion provided by a stepper motor. Multi-slice acquisitions of a Poly(methyl methacrylate) phantom and of a sea snail were done and the cross-sectional images were used to perform tri-dimensional (3D) visualization of the objects. Both kind of images (cross-sectional and 3D) are presented. Cross-sectional images using energy intervals of the spectrum are shown. Also, a simulation study of the influence of discharges (intrinsic to the MicroPatterned Gaseous Detector operation) in the resulting cross-sectional image was done and presented, showing no significant influence on the final imageElsevier2023-04-27T11:40:41Z2019-12-11T00:00:00Z2019-12-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/37407eng0168-900210.1016/j.nima.2019.162738Carramate, L.F.N.D.Silva, A.L.M.Azevedo, C.D.R.De Francesco, S.da Silva, A.M.Veloso, J.F.C.A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-05-06T04:45:20Zoai:ria.ua.pt:10773/37407Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-05-06T04:45:20Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
title |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
spellingShingle |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 Carramate, L.F.N.D. X-ray detectors Thick-COBRA Micropattern gaseous detectors Computerized tomography(CT) |
title_short |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
title_full |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
title_fullStr |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
title_full_unstemmed |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
title_sort |
Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4 |
author |
Carramate, L.F.N.D. |
author_facet |
Carramate, L.F.N.D. Silva, A.L.M. Azevedo, C.D.R. De Francesco, S. da Silva, A.M. Veloso, J.F.C.A. |
author_role |
author |
author2 |
Silva, A.L.M. Azevedo, C.D.R. De Francesco, S. da Silva, A.M. Veloso, J.F.C.A. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Carramate, L.F.N.D. Silva, A.L.M. Azevedo, C.D.R. De Francesco, S. da Silva, A.M. Veloso, J.F.C.A. |
dc.subject.por.fl_str_mv |
X-ray detectors Thick-COBRA Micropattern gaseous detectors Computerized tomography(CT) |
topic |
X-ray detectors Thick-COBRA Micropattern gaseous detectors Computerized tomography(CT) |
description |
A 2D-Thick-COBRA based detector with 10 × 10 cm2 active area operating in Ne/CH4 (95/5) flow mode, was applied to X-ray Computed Tomography (CT). The CT system is based on a third generation scanner with the object motion provided by a stepper motor. Multi-slice acquisitions of a Poly(methyl methacrylate) phantom and of a sea snail were done and the cross-sectional images were used to perform tri-dimensional (3D) visualization of the objects. Both kind of images (cross-sectional and 3D) are presented. Cross-sectional images using energy intervals of the spectrum are shown. Also, a simulation study of the influence of discharges (intrinsic to the MicroPatterned Gaseous Detector operation) in the resulting cross-sectional image was done and presented, showing no significant influence on the final image |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-12-11T00:00:00Z 2019-12-11 2023-04-27T11:40:41Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10773/37407 |
url |
http://hdl.handle.net/10773/37407 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0168-9002 10.1016/j.nima.2019.162738 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817543853642612736 |