Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4

Detalhes bibliográficos
Autor(a) principal: Carramate, L.F.N.D.
Data de Publicação: 2019
Outros Autores: Silva, A.L.M., Azevedo, C.D.R., De Francesco, S., da Silva, A.M., Veloso, J.F.C.A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10773/37407
Resumo: A 2D-Thick-COBRA based detector with 10 × 10 cm2 active area operating in Ne/CH4 (95/5) flow mode, was applied to X-ray Computed Tomography (CT). The CT system is based on a third generation scanner with the object motion provided by a stepper motor. Multi-slice acquisitions of a Poly(methyl methacrylate) phantom and of a sea snail were done and the cross-sectional images were used to perform tri-dimensional (3D) visualization of the objects. Both kind of images (cross-sectional and 3D) are presented. Cross-sectional images using energy intervals of the spectrum are shown. Also, a simulation study of the influence of discharges (intrinsic to the MicroPatterned Gaseous Detector operation) in the resulting cross-sectional image was done and presented, showing no significant influence on the final image
id RCAP_39c4e554ad2de9d7b670839aeccdd4b4
oai_identifier_str oai:ria.ua.pt:10773/37407
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4X-ray detectorsThick-COBRAMicropattern gaseous detectorsComputerized tomography(CT)A 2D-Thick-COBRA based detector with 10 × 10 cm2 active area operating in Ne/CH4 (95/5) flow mode, was applied to X-ray Computed Tomography (CT). The CT system is based on a third generation scanner with the object motion provided by a stepper motor. Multi-slice acquisitions of a Poly(methyl methacrylate) phantom and of a sea snail were done and the cross-sectional images were used to perform tri-dimensional (3D) visualization of the objects. Both kind of images (cross-sectional and 3D) are presented. Cross-sectional images using energy intervals of the spectrum are shown. Also, a simulation study of the influence of discharges (intrinsic to the MicroPatterned Gaseous Detector operation) in the resulting cross-sectional image was done and presented, showing no significant influence on the final imageElsevier2023-04-27T11:40:41Z2019-12-11T00:00:00Z2019-12-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/37407eng0168-900210.1016/j.nima.2019.162738Carramate, L.F.N.D.Silva, A.L.M.Azevedo, C.D.R.De Francesco, S.da Silva, A.M.Veloso, J.F.C.A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-05-06T04:45:20Zoai:ria.ua.pt:10773/37407Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-05-06T04:45:20Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
title Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
spellingShingle Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
Carramate, L.F.N.D.
X-ray detectors
Thick-COBRA
Micropattern gaseous detectors
Computerized tomography(CT)
title_short Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
title_full Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
title_fullStr Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
title_full_unstemmed Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
title_sort Multi-slice Energy Resolving CT system using a THCOBRA detector operating in NeCH4
author Carramate, L.F.N.D.
author_facet Carramate, L.F.N.D.
Silva, A.L.M.
Azevedo, C.D.R.
De Francesco, S.
da Silva, A.M.
Veloso, J.F.C.A.
author_role author
author2 Silva, A.L.M.
Azevedo, C.D.R.
De Francesco, S.
da Silva, A.M.
Veloso, J.F.C.A.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Carramate, L.F.N.D.
Silva, A.L.M.
Azevedo, C.D.R.
De Francesco, S.
da Silva, A.M.
Veloso, J.F.C.A.
dc.subject.por.fl_str_mv X-ray detectors
Thick-COBRA
Micropattern gaseous detectors
Computerized tomography(CT)
topic X-ray detectors
Thick-COBRA
Micropattern gaseous detectors
Computerized tomography(CT)
description A 2D-Thick-COBRA based detector with 10 × 10 cm2 active area operating in Ne/CH4 (95/5) flow mode, was applied to X-ray Computed Tomography (CT). The CT system is based on a third generation scanner with the object motion provided by a stepper motor. Multi-slice acquisitions of a Poly(methyl methacrylate) phantom and of a sea snail were done and the cross-sectional images were used to perform tri-dimensional (3D) visualization of the objects. Both kind of images (cross-sectional and 3D) are presented. Cross-sectional images using energy intervals of the spectrum are shown. Also, a simulation study of the influence of discharges (intrinsic to the MicroPatterned Gaseous Detector operation) in the resulting cross-sectional image was done and presented, showing no significant influence on the final image
publishDate 2019
dc.date.none.fl_str_mv 2019-12-11T00:00:00Z
2019-12-11
2023-04-27T11:40:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/37407
url http://hdl.handle.net/10773/37407
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0168-9002
10.1016/j.nima.2019.162738
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv mluisa.alvim@gmail.com
_version_ 1817543853642612736