Biological microsystem for measuring uric acid in biological fluids
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/1986 |
Resumo: | This paper describes a biological microsystem (bio-system) for measuring uric acid concentration in serum, plasma or urine. Its operation is based on optical absorption in a well-defined part of the visible spectrum. The bio-system is composed by two dies: one is fabricated in polystyrene and contains the microchannels and the other is fabricated in a CMOS standard process and contains the photodetector and readout electronics. The uric acid concentration is measured by using a mixture of 14µl of infinity™ uric acid reagent with 0.25µl of sample. The achieved sensitivity is 0.33 mg/dl (±0.6% of the value in urine of a healthy person), with a 1mm lightpath. Using an optical absorption method, a maximum peak at wavelength λ = 494 nm, is detected. This bio-system can be included in the group of low-cost disposable devices for biological fluids analysis. |
id |
RCAP_3a510d029727dee68f51dd8a5f66214c |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/1986 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Biological microsystem for measuring uric acid in biological fluidsBio-systemUric acidOptical absorptionScience & TechnologyThis paper describes a biological microsystem (bio-system) for measuring uric acid concentration in serum, plasma or urine. Its operation is based on optical absorption in a well-defined part of the visible spectrum. The bio-system is composed by two dies: one is fabricated in polystyrene and contains the microchannels and the other is fabricated in a CMOS standard process and contains the photodetector and readout electronics. The uric acid concentration is measured by using a mixture of 14µl of infinity™ uric acid reagent with 0.25µl of sample. The achieved sensitivity is 0.33 mg/dl (±0.6% of the value in urine of a healthy person), with a 1mm lightpath. Using an optical absorption method, a maximum peak at wavelength λ = 494 nm, is detected. This bio-system can be included in the group of low-cost disposable devices for biological fluids analysis.Fundação para a Ciência e a Tecnologia (FCT) - SFRH/BD/1281/2000, POCTI/33747/ESE/1999), FEDER.ElsevierUniversidade do MinhoMinas, GraçaMartins, Júlio S.Ribeiro, J. C.Wolffenbuttel, R. F.Correia, J. H.20042004-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/1986eng"Sensors and Actuators A : Physical". ISSN 0924-4247. 110 (2004) 33-38.0924-424710.1016/j.sna.2003.10.049info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:13:11Zoai:repositorium.sdum.uminho.pt:1822/1986Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:05:14.133961Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Biological microsystem for measuring uric acid in biological fluids |
title |
Biological microsystem for measuring uric acid in biological fluids |
spellingShingle |
Biological microsystem for measuring uric acid in biological fluids Minas, Graça Bio-system Uric acid Optical absorption Science & Technology |
title_short |
Biological microsystem for measuring uric acid in biological fluids |
title_full |
Biological microsystem for measuring uric acid in biological fluids |
title_fullStr |
Biological microsystem for measuring uric acid in biological fluids |
title_full_unstemmed |
Biological microsystem for measuring uric acid in biological fluids |
title_sort |
Biological microsystem for measuring uric acid in biological fluids |
author |
Minas, Graça |
author_facet |
Minas, Graça Martins, Júlio S. Ribeiro, J. C. Wolffenbuttel, R. F. Correia, J. H. |
author_role |
author |
author2 |
Martins, Júlio S. Ribeiro, J. C. Wolffenbuttel, R. F. Correia, J. H. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Minas, Graça Martins, Júlio S. Ribeiro, J. C. Wolffenbuttel, R. F. Correia, J. H. |
dc.subject.por.fl_str_mv |
Bio-system Uric acid Optical absorption Science & Technology |
topic |
Bio-system Uric acid Optical absorption Science & Technology |
description |
This paper describes a biological microsystem (bio-system) for measuring uric acid concentration in serum, plasma or urine. Its operation is based on optical absorption in a well-defined part of the visible spectrum. The bio-system is composed by two dies: one is fabricated in polystyrene and contains the microchannels and the other is fabricated in a CMOS standard process and contains the photodetector and readout electronics. The uric acid concentration is measured by using a mixture of 14µl of infinity™ uric acid reagent with 0.25µl of sample. The achieved sensitivity is 0.33 mg/dl (±0.6% of the value in urine of a healthy person), with a 1mm lightpath. Using an optical absorption method, a maximum peak at wavelength λ = 494 nm, is detected. This bio-system can be included in the group of low-cost disposable devices for biological fluids analysis. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004 2004-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/1986 |
url |
http://hdl.handle.net/1822/1986 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
"Sensors and Actuators A : Physical". ISSN 0924-4247. 110 (2004) 33-38. 0924-4247 10.1016/j.sna.2003.10.049 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132464231219200 |