Resumo: Introduction: During the stay of a newborn in the intensive unit, the clinical care management can involve the placement of invasive medical devices that need to be controlled by x-ray. The main goal of this work is to make a narrative review about the quality of imaging acquisition for radiographic confirmation of invasive medical devices in the neonatal intensive care units, according to the literature and the author’s experience. Material and Methods: We carried out a narrative review of the literature. We search the documents in the scientific data bases: PubMed; Science Direct; Google Scholar and Portal RCAAP. Books from the authors' private collections were also consulted. Results: We included 39 scientific documents: 26 articles; four guidelines/recommendations/consensus and nine books/book’s chapters. Discussion: Interventional procedures such as the placement of intravascular catheters, nasogastric or endotracheal tubes are a regular practice in the Neonatal Intensive Care Unit. The accurate placement of these devices is essential and the role of the chest and abdominal radiographs it’s very important in the control of these devices. The technical challenges associated to the realization of the x-ray images require more attention to the position and level of exposure than on the adult population. Exposure parameters, imaging post-processing must be optimized, to be possible to evaluate the tip positioning and trajectory of medical devices. At the same time, the image must have good anatomical quality so that any lesion on the underlying organs can be identified. Conclusion: The fast radiographic recognition of incorrect placing of medical devices and their complications its essential for a quick intervention so that the care of newborn can be maintained.
id RCAP_3c727c5adce778bfe235ffc68df464de
oai_identifier_str oai:roentgen.pt:article/70
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Radiographic control of medical devices in neonatology: a narrative reviewControlo radiográfico de dispositivos médicos em neonatologia: revisão narrativa.Newbornneonatology x-rayradiographic qualityintravascular cathetersendotracheal tubenasogastric tubeRecém-nascidosradiografia em neonatologiaqualidade radiográficacateteres intravascularestubo endotraquealsonda nasogástricaIntroduction: During the stay of a newborn in the intensive unit, the clinical care management can involve the placement of invasive medical devices that need to be controlled by x-ray. The main goal of this work is to make a narrative review about the quality of imaging acquisition for radiographic confirmation of invasive medical devices in the neonatal intensive care units, according to the literature and the author’s experience. Material and Methods: We carried out a narrative review of the literature. We search the documents in the scientific data bases: PubMed; Science Direct; Google Scholar and Portal RCAAP. Books from the authors' private collections were also consulted. Results: We included 39 scientific documents: 26 articles; four guidelines/recommendations/consensus and nine books/book’s chapters. Discussion: Interventional procedures such as the placement of intravascular catheters, nasogastric or endotracheal tubes are a regular practice in the Neonatal Intensive Care Unit. The accurate placement of these devices is essential and the role of the chest and abdominal radiographs it’s very important in the control of these devices. The technical challenges associated to the realization of the x-ray images require more attention to the position and level of exposure than on the adult population. Exposure parameters, imaging post-processing must be optimized, to be possible to evaluate the tip positioning and trajectory of medical devices. At the same time, the image must have good anatomical quality so that any lesion on the underlying organs can be identified. Conclusion: The fast radiographic recognition of incorrect placing of medical devices and their complications its essential for a quick intervention so that the care of newborn can be maintained.Introdução: A gestão clínica dos recém-nascidos nas unidades de cuidados intensivos neonatais implica a colocação de diversos dispositivos médicos invasivos que necessitam de controlo radiográfico. O principal objetivo deste trabalho consistiu em realizar uma revisão narrativa sobre as boas práticas a adotar na aquisição de imagens radiográficas, em unidades de cuidados intensivos neonatais, para o controlo de dispositivos médicos de acordo com a literatura publicada e a experiência dos autores. Material e Métodos: Realizou-se uma revisão narrativa da literatura. Recorreu-se às bases de dados científicas PubMed; Science Direct; Google Scholar e Portal RCAAP, para a recolha de documentos de análise. Foram, ainda, consultados livros das coleções particulares dos autores. Resultados: A revisão narrativa incidiu sobre 39 documentos, dos quais 26 artigos científicos, quatro guidelines/consensos/recomendações e nove livros/capítulos de livro. Desenvolvimento: A colocação de cateteres intravasculares, sondas nasogástricas e tubos endotraqueais são procedimentos interventivos habitualmente utilizados na prestação de cuidados a recém-nascidos prematuros internados nas unidades de cuidados intensivos neonatais. O posicionamento preciso destes dispositivos é essencial e a radiografia do tórax e abdómen desempenha um papel de extrema relevância no controlo e monitorização da colocação destes dispositivos. Os desafios técnicos inerentes à realização destes exames radiográficos assumem uma exigência suplementar atendendo aos ajustes ao posicionamento e parâmetros de exposição em relação à população adulta. Os parâmetros de aquisição, bem como o pós-processamento da imagem, deverão ser otimizados de forma a permitirem visualizar o trajeto dos dispositivos médicos em toda a sua extensão e demonstrarem inequivocamente a posição da sua extremidade distal. Ao mesmo tempo a imagem terá de apresentar leitura anatómica suficiente para a monitorização de eventuais lesões iatrogénicas. Conclusão: O célere reconhecimento radiográfico de dispositivos incorretamente colocados, assim como, as complicações que podem originar, é essencial para uma rápida intervenção que permita a prevenção do agravamento do estado clínico do recém-nascido.NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia2022-01-20info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.46885/roentgen.v3i1.70https://doi.org/10.46885/roentgen.v3i1.70ROENTGEN-Scientific Journal of Radiological Techniques; Vol. 3 No. 1 (2022): Research in Radiological Sciences; 54-64ROENTGEN-Revista Científica das Técnicas Radiológicas; v. 3 n. 1 (2022): A Investigação nas Ciências Radiológicas; 54-642184-7657reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://roentgen.pt/index.php/Principal/article/view/70https://roentgen.pt/index.php/Principal/article/view/70/62Direitos de Autor (c) 2022 ROENTGEN-Revista Científica das Técnicas Radiológicasinfo:eu-repo/semantics/openAccessReis, RaquelRebelo, SofiaPereira, José Manuel2023-12-20T16:17:10Zoai:roentgen.pt:article/70Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:55:20.342315Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Radiographic control of medical devices in neonatology: a narrative review
Controlo radiográfico de dispositivos médicos em neonatologia: revisão narrativa.
title Radiographic control of medical devices in neonatology: a narrative review
spellingShingle Radiographic control of medical devices in neonatology: a narrative review
Reis, Raquel
Newborn
neonatology x-ray
radiographic quality
intravascular catheters
endotracheal tube
nasogastric tube
Recém-nascidos
radiografia em neonatologia
qualidade radiográfica
cateteres intravasculares
tubo endotraqueal
sonda nasogástrica
title_short Radiographic control of medical devices in neonatology: a narrative review
title_full Radiographic control of medical devices in neonatology: a narrative review
title_fullStr Radiographic control of medical devices in neonatology: a narrative review
title_full_unstemmed Radiographic control of medical devices in neonatology: a narrative review
title_sort Radiographic control of medical devices in neonatology: a narrative review
author Reis, Raquel
author_facet Reis, Raquel
Rebelo, Sofia
Pereira, José Manuel
author_role author
author2 Rebelo, Sofia
Pereira, José Manuel
author2_role author
author
dc.contributor.author.fl_str_mv Reis, Raquel
Rebelo, Sofia
Pereira, José Manuel
dc.subject.por.fl_str_mv Newborn
neonatology x-ray
radiographic quality
intravascular catheters
endotracheal tube
nasogastric tube
Recém-nascidos
radiografia em neonatologia
qualidade radiográfica
cateteres intravasculares
tubo endotraqueal
sonda nasogástrica
topic Newborn
neonatology x-ray
radiographic quality
intravascular catheters
endotracheal tube
nasogastric tube
Recém-nascidos
radiografia em neonatologia
qualidade radiográfica
cateteres intravasculares
tubo endotraqueal
sonda nasogástrica
description Introduction: During the stay of a newborn in the intensive unit, the clinical care management can involve the placement of invasive medical devices that need to be controlled by x-ray. The main goal of this work is to make a narrative review about the quality of imaging acquisition for radiographic confirmation of invasive medical devices in the neonatal intensive care units, according to the literature and the author’s experience. Material and Methods: We carried out a narrative review of the literature. We search the documents in the scientific data bases: PubMed; Science Direct; Google Scholar and Portal RCAAP. Books from the authors' private collections were also consulted. Results: We included 39 scientific documents: 26 articles; four guidelines/recommendations/consensus and nine books/book’s chapters. Discussion: Interventional procedures such as the placement of intravascular catheters, nasogastric or endotracheal tubes are a regular practice in the Neonatal Intensive Care Unit. The accurate placement of these devices is essential and the role of the chest and abdominal radiographs it’s very important in the control of these devices. The technical challenges associated to the realization of the x-ray images require more attention to the position and level of exposure than on the adult population. Exposure parameters, imaging post-processing must be optimized, to be possible to evaluate the tip positioning and trajectory of medical devices. At the same time, the image must have good anatomical quality so that any lesion on the underlying organs can be identified. Conclusion: The fast radiographic recognition of incorrect placing of medical devices and their complications its essential for a quick intervention so that the care of newborn can be maintained.
publishDate 2022
dc.date.none.fl_str_mv 2022-01-20
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.46885/roentgen.v3i1.70
https://doi.org/10.46885/roentgen.v3i1.70
url https://doi.org/10.46885/roentgen.v3i1.70
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://roentgen.pt/index.php/Principal/article/view/70
https://roentgen.pt/index.php/Principal/article/view/70/62
dc.rights.driver.fl_str_mv Direitos de Autor (c) 2022 ROENTGEN-Revista Científica das Técnicas Radiológicas
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Direitos de Autor (c) 2022 ROENTGEN-Revista Científica das Técnicas Radiológicas
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia
publisher.none.fl_str_mv NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia
dc.source.none.fl_str_mv ROENTGEN-Scientific Journal of Radiological Techniques; Vol. 3 No. 1 (2022): Research in Radiological Sciences; 54-64
ROENTGEN-Revista Científica das Técnicas Radiológicas; v. 3 n. 1 (2022): A Investigação nas Ciências Radiológicas; 54-64
2184-7657
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136439962697728