Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats

Detalhes bibliográficos
Autor(a) principal: Coelho, Carolina Mourato Pedro
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/104489
Resumo: Trabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
id RCAP_40b5b8d83ff1617303860e24132e0dd6
oai_identifier_str oai:estudogeral.uc.pt:10316/104489
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of ratsBiocompatibilidade do novo cimento à base de silicato de cálcio TotalFill BC Sealer HiFlow em tecido subcutâneo de ratosCimentos silicato de cálcioBiocompatibilidadeImplantação subcutâneaMaterial de obturaçãoEndodontiaCalcium silicate-based sealersBiocompatibilitySubcutaneous implantationRoot canal filling materialEndodonticsTrabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de MedicinaIntrodução: O tratamento endodôntico compreende a preparação químico-mecânica dos canais radiculares seguida de uma obturação tridimensional. Os cimentos endodônticos devem possuir características físico-químicas adequadas e devem ser biocompatíveis. O objetivo do nosso estudo foi avaliar a biocompatibilidade de 2 cimentos endodônticos à base de silicato de cálcio, TotalFill BC Sealer (FKG, La Chaux-des-Fonds, Suíça) e TotalFill BC Sealer HiFlow (FKG, La Chaux-des-Fonds, Suíça) através da implantação subcutânea em tecido conjuntivo de ratos. Materiais e métodos: A implantação subcutânea foi realizada em 16 ratos Wistar. O estudo compreendeu 2 períodos de tempo e 4 grupos experimentais: controlo, AH Plus (Dentsply DeTrey, Konstanz, Alemanha), TotalFill BC Sealer e TotalFill BC Sealer HiFlow. A coloração com hematoxilina-eosina foi realizada para avaliar a reação inflamatória, o infiltrado de macrófagos e para medir a espessura da cápsula fibrosa. A coloração com Von Kossa foi utilizada para avaliar o potencial de mineralização dos materiais. Para a análise estatística dos dados não-paramétricos utilizou-se o teste Kruskal-Wallis, seguido do teste de Dunn. Para analisar a influência do tempo entre os materiais utilizou-se o teste Mann-Whitney U. P≤0.05.Resultados: Oito dias após a implantação, o AH Plus provocou uma reação inflamatória mais intensa quando comparada com a do controlo e do TotalFill BC Sealer (P≤0.05). O grupo do TotalFill BC Sealer HiFlow apresentou um maior infiltrado de macrófagos do que o controlo e o TotalFill BC Sealer (P≤0.05). Neste período, a espessura da cápsula fibrosa foi significativamente maior para o TotalFill BC Sealer do que para o controlo e AH Plus (P≤0.05) e o potencial de mineralização foi maior para o grupo do TotalFill BC Sealer HiFlow relativamente ao controlo e AH Plus (P≤0.05). Aos 30 dias, a reação inflamatória continuou a ser maior para o grupo do AH Plus do que para o controlo e TotalFill BC Sealer (P≤0.05). O infiltrado de macrófagos do TotalFill BC Sealer HiFlow foi significativamente maior do que o controlo e o AH Plus (P≤0.05) e as cápsulas fibrosas do TotalFill BC Sealer e do TotalFill BC Sealer HiFlow apresentaram-se mais espessas do que as do controlo (P≤0.05). Por fim, o potencial de mineralização foi significativamente maior nos grupos do TotalFill BC Sealer e TotalFill BC Sealer HiFlow (P≤0.05).Conclusão: Ambos os cimentos TotalFill BC e TotalFill BC HiFlow são biocompatíveis e apresentam potencial bioativo quando implantados em tecido subcutâneo.Introduction: Endodontic treatment comprehends a chemical and mechanical preparation of the root canals, followed by a three-dimensional obturation. Endodontic sealers must present adequate chemical and handling features and must be biocompatible. The aim of this study was to evaluate the biocompatibility of 2 new hydraulic calcium silicate-based materials, TotalFill BC Sealer (FKG, La Chaux-des-Fonds, Switzerland) and TotalFill BC Sealer HiFlow (FKG, La Chaux-des-Fonds, Switzerland) through subcutaneous implantation in connective tissue of rats.Materials and Methods: Subcutaneous implantation was performed in 16 young Wistar rats. The study comprised 2 time periods and 4 experimental groups: control group, AH Plus (Dentsply DeTrey, Konstanz, Germany) group, TotalFill BC Sealer and TotalFill BC Sealer HiFlow. Hematoxylin-eosin coloration was used to score the inflammatory reaction, macrophage infiltrate and to measure the thickness of the fibrous capsule. Von Kossa staining was performed to evaluate the mineralization potential. Kruskal-Wallis test was used to analyze non-parametric data followed by the Dunn’s test. To analyze the influence of the time within each material, a Mann-Whitney U test was used. P≤0.05.Results: Eight days after implantation, AH Plus provoked an inflammatory reaction more intense when compared with the control and TotalFill BC Sealer (P≤0.05). TotalFill BC Sealer HiFlow present a higher score for the macrophage infiltrate than TotalFill BC Sealer and control (P≤0.05). The fibrous capsule thickness in this period was significantly higher for the TotalFill BC Sealer group than for the control and AH Plus (P≤0.05) and the mineralization potential was higher for the TotalFill BC Sealer HiFlow group when compared with the control and AH Plus (P≤0.05). At day 30, the score for the inflammatory reaction remained higher for the AH Plus group than for the control and TotalFill BC Sealer (P≤0.05). The macrophage infiltrate of the TotalFill BC Sealer HiFlow was significantly higher than control and AH Plus groups (P≤0.05) and the fibrous capsule of the TotalFill BC Sealer and TotalFill BC Sealer HiFlow was thicker than the control (P≤0.05). Finally, the mineralization potential was significantly higher for TotalFill BC Sealer and TotalFill BC Sealer HiFlow groups (P≤0.05).Conclusion: Both TotalFill BC sealer and TotalFill BC HiFlow are biocompatible and present potential bioactivity when implanted in the subcutaneous tissue.2020-07-23info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/104489http://hdl.handle.net/10316/104489TID:203159012engCoelho, Carolina Mourato Pedroinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-13T21:49:52Zoai:estudogeral.uc.pt:10316/104489Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:21:11.815082Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
Biocompatibilidade do novo cimento à base de silicato de cálcio TotalFill BC Sealer HiFlow em tecido subcutâneo de ratos
title Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
spellingShingle Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
Coelho, Carolina Mourato Pedro
Cimentos silicato de cálcio
Biocompatibilidade
Implantação subcutânea
Material de obturação
Endodontia
Calcium silicate-based sealers
Biocompatibility
Subcutaneous implantation
Root canal filling material
Endodontics
title_short Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
title_full Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
title_fullStr Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
title_full_unstemmed Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
title_sort Biocompatibility of new calcium-silicate based sealer TotalFill BC Sealer HiFlow in subcutaneous tissue of rats
author Coelho, Carolina Mourato Pedro
author_facet Coelho, Carolina Mourato Pedro
author_role author
dc.contributor.author.fl_str_mv Coelho, Carolina Mourato Pedro
dc.subject.por.fl_str_mv Cimentos silicato de cálcio
Biocompatibilidade
Implantação subcutânea
Material de obturação
Endodontia
Calcium silicate-based sealers
Biocompatibility
Subcutaneous implantation
Root canal filling material
Endodontics
topic Cimentos silicato de cálcio
Biocompatibilidade
Implantação subcutânea
Material de obturação
Endodontia
Calcium silicate-based sealers
Biocompatibility
Subcutaneous implantation
Root canal filling material
Endodontics
description Trabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
publishDate 2020
dc.date.none.fl_str_mv 2020-07-23
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/104489
http://hdl.handle.net/10316/104489
TID:203159012
url http://hdl.handle.net/10316/104489
identifier_str_mv TID:203159012
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134102920626176