Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/100102 https://doi.org/10.1016/j.enbuild.2022.111896 |
Resumo: | This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
id |
RCAP_44b0ee0619f8007d36e6a2d12e8ee2fd |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/100102 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian PalazzoHeLLoEnvelope technologiesEnergy retrofitHistoric wallHeritageMonitoring campaignIn situHygrothermal measurementHygrothermal simulationDynamic conditionsThis is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)This paper presents the newly developed study, methodology and assessment of the hygrothermal per- formance of a historic building wall retrofitted with three different internal insulation technologies, with- out a vapour barrier. It aims at assessing any possible condensation problems at the most critical point of the tested stratigraphy (namely, in between the wall and the insulation material) and to limit the mod- ification of the original hygrothermal behaviour of the original wall’s materials with the addition of a vapour layer, as would commonly be used. This evaluation was performed through in situ measurements and dynamic software simulations. In situ data was used for calibrating the 2D simulation model con- ducted with Delphin software 6.0.20. Under the climatic conditions in Ferrara (Italy), the results of both the in-situ monitoring and simula- tion evidenced no risk of frost damage to the building’s original wall. With regards to the risk of intersti- tial condensation, simulations showed no high risk even in the absence of a water vapour barrier. Additionally, the amount of water vapour collected during the winter season dried out during the spring/- summer period.The results presented in this paper are part of the HeLLo project that has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska- Curie grant agreement No 796712.2022-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/100102http://hdl.handle.net/10316/100102https://doi.org/10.1016/j.enbuild.2022.111896eng03787788https://www.sciencedirect.com/science/article/pii/S0378778822000676Andreotti, MircoCalzolari, MartaDavoli, PietromariaDias Pereira, Luísainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-03T20:46:00Zoai:estudogeral.uc.pt:10316/100102Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:17:34.035805Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
title |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
spellingShingle |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo Andreotti, Mirco HeLLo Envelope technologies Energy retrofit Historic wall Heritage Monitoring campaign In situ Hygrothermal measurement Hygrothermal simulation Dynamic conditions |
title_short |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
title_full |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
title_fullStr |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
title_full_unstemmed |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
title_sort |
Hygrothermal performance of an internally insulated masonry wall: Experimentations without a vapour barrier in a historic Italian Palazzo |
author |
Andreotti, Mirco |
author_facet |
Andreotti, Mirco Calzolari, Marta Davoli, Pietromaria Dias Pereira, Luísa |
author_role |
author |
author2 |
Calzolari, Marta Davoli, Pietromaria Dias Pereira, Luísa |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Andreotti, Mirco Calzolari, Marta Davoli, Pietromaria Dias Pereira, Luísa |
dc.subject.por.fl_str_mv |
HeLLo Envelope technologies Energy retrofit Historic wall Heritage Monitoring campaign In situ Hygrothermal measurement Hygrothermal simulation Dynamic conditions |
topic |
HeLLo Envelope technologies Energy retrofit Historic wall Heritage Monitoring campaign In situ Hygrothermal measurement Hygrothermal simulation Dynamic conditions |
description |
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-04 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/100102 http://hdl.handle.net/10316/100102 https://doi.org/10.1016/j.enbuild.2022.111896 |
url |
http://hdl.handle.net/10316/100102 https://doi.org/10.1016/j.enbuild.2022.111896 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
03787788 https://www.sciencedirect.com/science/article/pii/S0378778822000676 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799134070597222400 |