Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL

Detalhes bibliográficos
Autor(a) principal: Marques, JP
Data de Publicação: 2015
Outros Autores: Rosa, AM, Quendera, B, Silva, F, Mira, J, Lobo, C, Castelo-Branco, M, Murta, JN
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.4/1959
Resumo: PURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.
id RCAP_44bdb3d702604b4d4ae8573dcb3aa8d7
oai_identifier_str oai:rihuc.huc.min-saude.pt:10400.4/1959
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOLImplante de Lentes Intra-ocularesAcuidade VisualPURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.RIHUCMarques, JPRosa, AMQuendera, BSilva, FMira, JLobo, CCastelo-Branco, MMurta, JN2016-09-30T15:36:18Z20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.4/1959engEur J Ophthalmol. 2015 Nov-Dec;25(6):516-24.10.5301/ejo.5000638info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-11T14:23:15Zoai:rihuc.huc.min-saude.pt:10400.4/1959Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:04:24.190117Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
title Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
spellingShingle Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
Marques, JP
Implante de Lentes Intra-oculares
Acuidade Visual
title_short Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
title_full Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
title_fullStr Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
title_full_unstemmed Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
title_sort Quantitative evaluation of visual function 12 months after bilateral implantation of a diffractive trifocal IOL
author Marques, JP
author_facet Marques, JP
Rosa, AM
Quendera, B
Silva, F
Mira, J
Lobo, C
Castelo-Branco, M
Murta, JN
author_role author
author2 Rosa, AM
Quendera, B
Silva, F
Mira, J
Lobo, C
Castelo-Branco, M
Murta, JN
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv RIHUC
dc.contributor.author.fl_str_mv Marques, JP
Rosa, AM
Quendera, B
Silva, F
Mira, J
Lobo, C
Castelo-Branco, M
Murta, JN
dc.subject.por.fl_str_mv Implante de Lentes Intra-oculares
Acuidade Visual
topic Implante de Lentes Intra-oculares
Acuidade Visual
description PURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.
publishDate 2015
dc.date.none.fl_str_mv 2015
2015-01-01T00:00:00Z
2016-09-30T15:36:18Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.4/1959
url http://hdl.handle.net/10400.4/1959
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Eur J Ophthalmol. 2015 Nov-Dec;25(6):516-24.
10.5301/ejo.5000638
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1817551193031835648