Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis

Detalhes bibliográficos
Autor(a) principal: Almeida, Sofia A. A.
Data de Publicação: 2010
Outros Autores: Rebelo, Tânia S. C. R., Heitor, Ana M., Oliveira, M. Beatriz P. P., Sales, M. Goreti F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.22/3041
Resumo: Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
id RCAP_47045e2ea32a17b42f1059a2f722d2d4
oai_identifier_str oai:recipp.ipp.pt:10400.22/3041
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Flow-injection potentiometric method for the routine determination of chloride: application to bread analysisChlorideIon selective electrodeBreadFlow-injection analysisFoodBread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.Bentham Science Publishers Ltd.Repositório Científico do Instituto Politécnico do PortoAlmeida, Sofia A. A.Rebelo, Tânia S. C. R.Heitor, Ana M.Oliveira, M. Beatriz P. P.Sales, M. Goreti F.2013-11-29T15:30:51Z20102010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/3041eng1573-411010.2174/1573411011006040277metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:42:51Zoai:recipp.ipp.pt:10400.22/3041Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:24:04.827609Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
title Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
spellingShingle Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
Almeida, Sofia A. A.
Chloride
Ion selective electrode
Bread
Flow-injection analysis
Food
title_short Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
title_full Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
title_fullStr Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
title_full_unstemmed Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
title_sort Flow-injection potentiometric method for the routine determination of chloride: application to bread analysis
author Almeida, Sofia A. A.
author_facet Almeida, Sofia A. A.
Rebelo, Tânia S. C. R.
Heitor, Ana M.
Oliveira, M. Beatriz P. P.
Sales, M. Goreti F.
author_role author
author2 Rebelo, Tânia S. C. R.
Heitor, Ana M.
Oliveira, M. Beatriz P. P.
Sales, M. Goreti F.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Almeida, Sofia A. A.
Rebelo, Tânia S. C. R.
Heitor, Ana M.
Oliveira, M. Beatriz P. P.
Sales, M. Goreti F.
dc.subject.por.fl_str_mv Chloride
Ion selective electrode
Bread
Flow-injection analysis
Food
topic Chloride
Ion selective electrode
Bread
Flow-injection analysis
Food
description Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
publishDate 2010
dc.date.none.fl_str_mv 2010
2010-01-01T00:00:00Z
2013-11-29T15:30:51Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/3041
url http://hdl.handle.net/10400.22/3041
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1573-4110
10.2174/1573411011006040277
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Bentham Science Publishers Ltd.
publisher.none.fl_str_mv Bentham Science Publishers Ltd.
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1817552111851798528