Reliability Loss with Sampling Rate Reduction

Detalhes bibliográficos
Autor(a) principal: Sousa, P
Data de Publicação: 2015
Outros Autores: Almeida, R, Marta Silva, Rocha, AP
Tipo de documento: Livro
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/10216/102356
Resumo: High sampling frequency is not usually available in hospital monitoring systems, what can limit the usefulness of the data, namely for repolarization measures. In this work the reliability of beat-to-beat measures using low sampling frequency is quantified with respect to the original high sampling rate. ECG recordings originally at 1000 Hz, including intensive care patients data, were downsampled to 500 Hz and to 250 Hz. Automatic delineation was applied to extract beat-to-beat intervals. The reliability was measured considering concordance correlation coefficient (CCC) and intraclass correlation coefficient (ICC); the Information-based measure of disagreement (IBMD) was used for agreement quantification. High reliability and low disagreement were generally found. Using the conventional interpretation excellent consistency was found at 250 HZ for more than 68%, 50%, 50% and 58% of the cases for RR, RT QT and QT(c), respectively. Results indicate that at 250 Hz RR, RT QT and QT(c) measures are still reliable compared with the values at 1000 Hz.
id RCAP_4b40b6d83bae852c51645577e74309a7
oai_identifier_str oai:repositorio-aberto.up.pt:10216/102356
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Reliability Loss with Sampling Rate ReductionHigh sampling frequency is not usually available in hospital monitoring systems, what can limit the usefulness of the data, namely for repolarization measures. In this work the reliability of beat-to-beat measures using low sampling frequency is quantified with respect to the original high sampling rate. ECG recordings originally at 1000 Hz, including intensive care patients data, were downsampled to 500 Hz and to 250 Hz. Automatic delineation was applied to extract beat-to-beat intervals. The reliability was measured considering concordance correlation coefficient (CCC) and intraclass correlation coefficient (ICC); the Information-based measure of disagreement (IBMD) was used for agreement quantification. High reliability and low disagreement were generally found. Using the conventional interpretation excellent consistency was found at 250 HZ for more than 68%, 50%, 50% and 58% of the cases for RR, RT QT and QT(c), respectively. Results indicate that at 250 Hz RR, RT QT and QT(c) measures are still reliable compared with the values at 1000 Hz.20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/102356eng10.1109/cic.2015.7411004Sousa, PAlmeida, RMarta SilvaRocha, APinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-09-27T09:41:05Zoai:repositorio-aberto.up.pt:10216/102356Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-09-27T09:41:05Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Reliability Loss with Sampling Rate Reduction
title Reliability Loss with Sampling Rate Reduction
spellingShingle Reliability Loss with Sampling Rate Reduction
Sousa, P
title_short Reliability Loss with Sampling Rate Reduction
title_full Reliability Loss with Sampling Rate Reduction
title_fullStr Reliability Loss with Sampling Rate Reduction
title_full_unstemmed Reliability Loss with Sampling Rate Reduction
title_sort Reliability Loss with Sampling Rate Reduction
author Sousa, P
author_facet Sousa, P
Almeida, R
Marta Silva
Rocha, AP
author_role author
author2 Almeida, R
Marta Silva
Rocha, AP
author2_role author
author
author
dc.contributor.author.fl_str_mv Sousa, P
Almeida, R
Marta Silva
Rocha, AP
description High sampling frequency is not usually available in hospital monitoring systems, what can limit the usefulness of the data, namely for repolarization measures. In this work the reliability of beat-to-beat measures using low sampling frequency is quantified with respect to the original high sampling rate. ECG recordings originally at 1000 Hz, including intensive care patients data, were downsampled to 500 Hz and to 250 Hz. Automatic delineation was applied to extract beat-to-beat intervals. The reliability was measured considering concordance correlation coefficient (CCC) and intraclass correlation coefficient (ICC); the Information-based measure of disagreement (IBMD) was used for agreement quantification. High reliability and low disagreement were generally found. Using the conventional interpretation excellent consistency was found at 250 HZ for more than 68%, 50%, 50% and 58% of the cases for RR, RT QT and QT(c), respectively. Results indicate that at 250 Hz RR, RT QT and QT(c) measures are still reliable compared with the values at 1000 Hz.
publishDate 2015
dc.date.none.fl_str_mv 2015
2015-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/book
format book
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/102356
url https://hdl.handle.net/10216/102356
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1109/cic.2015.7411004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv mluisa.alvim@gmail.com
_version_ 1817548419470721025