DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS

Detalhes bibliográficos
Autor(a) principal: Teodoro, Sara Helena Marques
Data de Publicação: 2022
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/102495
Resumo: Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina
id RCAP_4c191c2fb5ba363e64f78858fac17e02
oai_identifier_str oai:estudogeral.uc.pt:10316/102495
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOSSoftware development for hepatocyte function quantification when using radioisotopic methodsCintigrafiaDesconvoluçãoFunção hepatocitáriaMedicina nuclearQuantificação hepatobiliarDeconvolution operationHepatobiliar quantizationHepatocitary functionNuclear medicineRadionuclide imagingTrabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de MedicinaIntrodução: Não existe um método que, isoladamente, seja fiável para a avaliação da função hepática, sendo frequente o uso da cintigrafia hepatobiliar ou medição dos níveis séricos de substâncias metabolizadas no fígado, para esse efeito. A cintigrafia hepática tem um valor acrescido de diagnóstico e prognóstico em patologias hepatobiliares, quando associada a uma análise funcional quantificada da função hepatocitária através da atividade do radiofármaco. Com esse objetivo, pretendeu-se implementar um programa computacional que permita uma análise funcional quantificada da função hepática, após seleção do método e modelos matemático mais adequados.Material e métodos: O método escolhido para modelar as curvas de atividade plasmática e hepática do radiofármaco, tem como base modelos compartimentais. A função da retenção hepática é obtida por desconvolução. Um programa computacional, associado a um interface user-friendly, foi desenvolvido no software Matlab Apps Designer. Resultados: O método proposto foi implementado, através de código, num programa computacional. Foi obtida uma interface que permite a um utilizador, sem conhecimentos de programação, aceder a informações qualitativas e quantitativas de dados cintigráficos hepatobiliares. Através da seleção de regiões de interesse, o programa permite obter diferentes curvas de atividade-tempo do radiofármaco. Os parâmetros quantificados apresentados pela interface do programa são a fração de extração hepatocitária, o tempo de semivida efetiva de excreção do radiofármaco, tempo médio de trânsito e tempo máximo de atividade hepática. A validação do programa foi realizada através do uso de dados cintigráficos armazenados em bases de dados, comparando alguns dos parâmetros quantificados obtidos neste trabalho com os valores obtidos por outros programas entretanto desatualizados.Discussão e conclusão: Os resultados obtidos mostram que o programa, em conjunto com a interface desenhada, funciona de acordo com os objetivos traçados. A prova de conceito do programa mostrou resultados que validam o trabalho desenvolvido. O método e o programa propostos são uma ferramenta de elevado valor na pesquisa de alterações da função hepática, para o uso em investigação ou na área médica e cirúrgica, quantificando numericamente os dados cintigráficos.Introduction: There is no isolated and reliable method for the assessment of liver function. Hepatobiliary scintigraphy and measurement of serum levels of substances metabolized in the liver are frequently used for this purpose. Liver scintigraphy has an additional diagnostic and prognostic value in hepatobiliary pathologies, when associated with a quantified functional analysis of the liver function through radiopharmaceutical activity. With this objective, a computer program was intended to be implemented that allows a quantified functional analysis of liver function, after research and choice of the most appropriated method and mathematical models.Material and methods: The method chosen to model the plasma and hepatic activity curves of the radiopharmaceutical is based on compartmental models. Liver retention function is obtained by deconvolution. A computer program, associated with a user-friendly interface, was developed using the Matlab Apps Designer software.Results: The proposed method was designed and implemented in a computer program. An interface that allows users, without programming knowledge, to access qualitative and quantitative information from hepatobiliary scintigraphic data, was obtained. Through the selection of regions of interest, the program allows to obtain different activity-time curves of the radiopharmaceutical. The quantified parameters presented by the interface are the hepatic extraction fraction, the effective half-life of radiopharmaceutical excretion, mean transit time and maximum time of hepatic activity. The validation of the program was carried out using scintigraphic data stored in databases, comparing some of the quantified parameters obtained in this work with the values obtained by other outdated programs.Discussion and conclusion: The obtained results show that the program, together with the designed interface, works according to the outlined objectives. The program proof of concept showed results that validate the developed work. The proposed method and program are a highly valuable tool in the investigation of changes in liver function, for use in research or in medical and surgical field, numerically quantifying the scintigraphic data.2022-05-18info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/102495http://hdl.handle.net/10316/102495TID:203067770porTeodoro, Sara Helena Marquesinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-30T20:32:13Zoai:estudogeral.uc.pt:10316/102495Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:19:28.742620Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
Software development for hepatocyte function quantification when using radioisotopic methods
title DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
spellingShingle DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
Teodoro, Sara Helena Marques
Cintigrafia
Desconvolução
Função hepatocitária
Medicina nuclear
Quantificação hepatobiliar
Deconvolution operation
Hepatobiliar quantization
Hepatocitary function
Nuclear medicine
Radionuclide imaging
title_short DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
title_full DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
title_fullStr DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
title_full_unstemmed DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
title_sort DESENVOLVIMENTO DE PROGRAMA COMPUTACIONAL PARA QUANTIFICAÇÃO DA FUNÇÃO HEPATOCITÁRIA POR MÉTODOS RADIOISOTÓPICOS
author Teodoro, Sara Helena Marques
author_facet Teodoro, Sara Helena Marques
author_role author
dc.contributor.author.fl_str_mv Teodoro, Sara Helena Marques
dc.subject.por.fl_str_mv Cintigrafia
Desconvolução
Função hepatocitária
Medicina nuclear
Quantificação hepatobiliar
Deconvolution operation
Hepatobiliar quantization
Hepatocitary function
Nuclear medicine
Radionuclide imaging
topic Cintigrafia
Desconvolução
Função hepatocitária
Medicina nuclear
Quantificação hepatobiliar
Deconvolution operation
Hepatobiliar quantization
Hepatocitary function
Nuclear medicine
Radionuclide imaging
description Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina
publishDate 2022
dc.date.none.fl_str_mv 2022-05-18
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/102495
http://hdl.handle.net/10316/102495
TID:203067770
url http://hdl.handle.net/10316/102495
identifier_str_mv TID:203067770
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134089205252096