The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.9/2480 |
Resumo: | This study addresses the energetic performance of an attached-sunspace applied to an existing residential building in Portugal. Four configurations (two attached, one integrated and one partially integrated) are studied in six different climatic zones. In addition other key parameters are considered such as ventilation (with or without natural ventilation), shading devices (one external and two internal configurations), number of glazed surface layers (single glazed and double glazed) and orientation (South, East and West). The thermal performance analysis, carried out using a dynamic simulation code, proved that energy savings for retrofitting design can be very important and that in climates with warm summers the risk of overheating can be considerably diminished through an accurate analysis based on modeling. |
id |
RCAP_4db756e6bd343717a49390e605f0ccf5 |
---|---|
oai_identifier_str |
oai:repositorio.lneg.pt:10400.9/2480 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in PortugalAttached-sunspaceRetrofit measuresResidential buildingsThermal performanceSimulationThis study addresses the energetic performance of an attached-sunspace applied to an existing residential building in Portugal. Four configurations (two attached, one integrated and one partially integrated) are studied in six different climatic zones. In addition other key parameters are considered such as ventilation (with or without natural ventilation), shading devices (one external and two internal configurations), number of glazed surface layers (single glazed and double glazed) and orientation (South, East and West). The thermal performance analysis, carried out using a dynamic simulation code, proved that energy savings for retrofitting design can be very important and that in climates with warm summers the risk of overheating can be considerably diminished through an accurate analysis based on modeling.ElsevierRepositório do LNEGAelenei, DanielLeal, Hugo de AzevedoAelenei, Laura Elena2014-05-26T15:25:23Z2014-01-01T00:00:00Z2014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.9/2480engAelenei, D.; Leal, H. de Azevedo; Aelenei, L. The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal. In: Energy Procedia, 2014, Vol. 48, p. 1436-14411876-6102info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-06T12:27:31Zoai:repositorio.lneg.pt:10400.9/2480Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:35:22.455348Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
title |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
spellingShingle |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal Aelenei, Daniel Attached-sunspace Retrofit measures Residential buildings Thermal performance Simulation |
title_short |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
title_full |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
title_fullStr |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
title_full_unstemmed |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
title_sort |
The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal |
author |
Aelenei, Daniel |
author_facet |
Aelenei, Daniel Leal, Hugo de Azevedo Aelenei, Laura Elena |
author_role |
author |
author2 |
Leal, Hugo de Azevedo Aelenei, Laura Elena |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Repositório do LNEG |
dc.contributor.author.fl_str_mv |
Aelenei, Daniel Leal, Hugo de Azevedo Aelenei, Laura Elena |
dc.subject.por.fl_str_mv |
Attached-sunspace Retrofit measures Residential buildings Thermal performance Simulation |
topic |
Attached-sunspace Retrofit measures Residential buildings Thermal performance Simulation |
description |
This study addresses the energetic performance of an attached-sunspace applied to an existing residential building in Portugal. Four configurations (two attached, one integrated and one partially integrated) are studied in six different climatic zones. In addition other key parameters are considered such as ventilation (with or without natural ventilation), shading devices (one external and two internal configurations), number of glazed surface layers (single glazed and double glazed) and orientation (South, East and West). The thermal performance analysis, carried out using a dynamic simulation code, proved that energy savings for retrofitting design can be very important and that in climates with warm summers the risk of overheating can be considerably diminished through an accurate analysis based on modeling. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-05-26T15:25:23Z 2014-01-01T00:00:00Z 2014-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.9/2480 |
url |
http://hdl.handle.net/10400.9/2480 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Aelenei, D.; Leal, H. de Azevedo; Aelenei, L. The use of attached-sunspaces in retrofitting design: the case of residential buildings in Portugal. In: Energy Procedia, 2014, Vol. 48, p. 1436-1441 1876-6102 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130218778066944 |