Resumo: The most important standard for collector testing in Europe is the EN 12975:2006 which is applied in all the major laboratories and is the reference for the Solar Keymark certification. Besides the steady-state method, the EN 12975 allows the application of the quasi-dynamic method performed outdoors in natural conditions with variable radiation and ambient temperature. The available number of days for each test was investigated by analyzing meteorological data series acquired in the Solar Energy Laboratory (LES) in Lisbon since 2008 showing the advantage of the quasi-dynamic test. Both the steady-state and the quasi-dynamic methods were applied to five collectors of different types (two flat plate collectors, one evacuated tube collector with a back reflector and direct flow circulation, one evacuated tube collector with heat pipes, and a CPC collector). The results were compared and a good agreement between the steady-state and the quasi-dynamic test results was observed. Issues concerning the incidence angle modifiers and the effective thermal capacity of the collectors were analyzed in detail, which resulted in the identification of model and test limitations. Suggestions are given to improve the test methodology and the data analysis of quasi-dynamic test.
id RCAP_50391a33a7dd21248fc54f73545de638
oai_identifier_str oai:repositorio.lneg.pt:10400.9/2647
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Testing of solar thermal collectors under transient conditionsSolar collector testingQuasi-dynamic modelSteady-state modelEN 12975The most important standard for collector testing in Europe is the EN 12975:2006 which is applied in all the major laboratories and is the reference for the Solar Keymark certification. Besides the steady-state method, the EN 12975 allows the application of the quasi-dynamic method performed outdoors in natural conditions with variable radiation and ambient temperature. The available number of days for each test was investigated by analyzing meteorological data series acquired in the Solar Energy Laboratory (LES) in Lisbon since 2008 showing the advantage of the quasi-dynamic test. Both the steady-state and the quasi-dynamic methods were applied to five collectors of different types (two flat plate collectors, one evacuated tube collector with a back reflector and direct flow circulation, one evacuated tube collector with heat pipes, and a CPC collector). The results were compared and a good agreement between the steady-state and the quasi-dynamic test results was observed. Issues concerning the incidence angle modifiers and the effective thermal capacity of the collectors were analyzed in detail, which resulted in the identification of model and test limitations. Suggestions are given to improve the test methodology and the data analysis of quasi-dynamic test.ElsevierRepositório do LNEGOsório, TiagoCarvalho, Maria João2015-03-17T15:34:41Z2014-01-01T00:00:00Z2014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.9/2647engOsório, T.; Carvalho, M.J. - Testing of solar thermal collectors under transient conditions. In: Solar Energy, 2014, Vol. 104, p. 71-810038-092Xinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-06T12:27:48Zoai:repositorio.lneg.pt:10400.9/2647Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:35:37.363280Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Testing of solar thermal collectors under transient conditions
title Testing of solar thermal collectors under transient conditions
spellingShingle Testing of solar thermal collectors under transient conditions
Osório, Tiago
Solar collector testing
Quasi-dynamic model
Steady-state model
EN 12975
title_short Testing of solar thermal collectors under transient conditions
title_full Testing of solar thermal collectors under transient conditions
title_fullStr Testing of solar thermal collectors under transient conditions
title_full_unstemmed Testing of solar thermal collectors under transient conditions
title_sort Testing of solar thermal collectors under transient conditions
author Osório, Tiago
author_facet Osório, Tiago
Carvalho, Maria João
author_role author
author2 Carvalho, Maria João
author2_role author
dc.contributor.none.fl_str_mv Repositório do LNEG
dc.contributor.author.fl_str_mv Osório, Tiago
Carvalho, Maria João
dc.subject.por.fl_str_mv Solar collector testing
Quasi-dynamic model
Steady-state model
EN 12975
topic Solar collector testing
Quasi-dynamic model
Steady-state model
EN 12975
description The most important standard for collector testing in Europe is the EN 12975:2006 which is applied in all the major laboratories and is the reference for the Solar Keymark certification. Besides the steady-state method, the EN 12975 allows the application of the quasi-dynamic method performed outdoors in natural conditions with variable radiation and ambient temperature. The available number of days for each test was investigated by analyzing meteorological data series acquired in the Solar Energy Laboratory (LES) in Lisbon since 2008 showing the advantage of the quasi-dynamic test. Both the steady-state and the quasi-dynamic methods were applied to five collectors of different types (two flat plate collectors, one evacuated tube collector with a back reflector and direct flow circulation, one evacuated tube collector with heat pipes, and a CPC collector). The results were compared and a good agreement between the steady-state and the quasi-dynamic test results was observed. Issues concerning the incidence angle modifiers and the effective thermal capacity of the collectors were analyzed in detail, which resulted in the identification of model and test limitations. Suggestions are given to improve the test methodology and the data analysis of quasi-dynamic test.
publishDate 2014
dc.date.none.fl_str_mv 2014-01-01T00:00:00Z
2014-01-01T00:00:00Z
2015-03-17T15:34:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.9/2647
url http://hdl.handle.net/10400.9/2647
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Osório, T.; Carvalho, M.J. - Testing of solar thermal collectors under transient conditions. In: Solar Energy, 2014, Vol. 104, p. 71-81
0038-092X
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130221757071360